• 제목/요약/키워드: Planning Scheme

검색결과 409건 처리시간 0.03초

다중표적 뼈 전이암의 하이브리드 세기변조(modified hybrid-VMAT) 방사선치료계획 유용성 평가 (Evaluation of the Modified Hybrid-VMAT for multiple bone metastatic cancer)

  • 정일훈;조윤진;장원석;김세준;하진숙;전미진;정인호;김종대;신동봉;이익재
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.161-167
    • /
    • 2018
  • 목 적 : 동일 선상축(co-axial image)의 다발성 뼈 전이암에 대한 하이브리드 세기변조(modified hybrid-VMAT) 계획의 유용성을 평가하고자 한다. 대상 및 방법 : 동일 선상축의 다발성 뼈 전이암환자 총 5명을 대상으로 치료계획시스템(Ray station, 5.0.2.35, Sweden)을 이용하여 치료계획을 수립하였다. 치료계획용적(planning target volume, PTV) 처방 선량은 30 Gy로 설정하여 총 3가지 치료계획: 용적변조회전치료계획(volumetric modulated arc therapy, VMAT); 배경방사선(background)을 고려하지 않은 하이브리드 용적변조회전치료계획(hybrid VMAT, VMAT(h)); 배경방사선을 고려한 하이브리드 용적변조회전치료계획(modified hybrid VMAT, VMAT(mh))을 비교하였다. 선량용적히스토그램(dose volume histogram, DVH)을 이용하여 PTV의 maximum dose($D_{max}$), mean dose($D_{mean}$), 처방선량지수(conformity index, CI), 선량균질지수(homogeneity Index, HI) 및 손상위험장기(organ at risk, OAR)의 선량을 분석하였다. 또한 monitor unit(MU)와 치료시간(beam on time)을 분석하였다. 결 과 : VMAT, VMAT(h)과 VMAT(mh)의 PTV $D_{max}$는 3188.33 cGy, 3526 cGy, 3285.67 cGy이고, $D_{mean}$은 3081 cGy, 3252 cGy, 3094 cGy이고, CI는 $1.35{\pm}0.19$, $1.43{\pm}0.12$, $1.30{\pm}0.06$이고, HI는 $1.06{\pm}0.01$, $1.14{\pm}0.06$, $1.09{\pm}0.02$로 평가되었다. VMAT(h)과 VMAT(mh)의 OAR은 3 % 증가와 18 % 감소하는 것으로 평가되었다. 추가적으로 평균 MU는 904.90, 911.73, 1202.13 그리고 평균 Beam on time은 $128.67{\pm}10.97$초, $167.33{\pm}7.57$초, $190.33{\pm}4.51$초 소요되었다. 결 론 : 다중표적 치료 시에는 modified Hybrid-VMAT를 적용하면 선량의 겹침이 보정되어 과선량(over dose) 조사되는 것을 방지하는 다중표적을 치료할 수 있다. 그리고 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 modified Hybrid-VMAT의 임상적 효능을 확인하기 위해 많은 수의 환자를 대상으로 한 장기 추적 관찰이 필요하다.

  • PDF

지방자치(地方自治)와 국민경제(國民經濟) 및 지방재정(地方財政) (Local Autonomy, National Economy and Local Public Finance)

  • 이계식
    • KDI Journal of Economic Policy
    • /
    • 제13권2호
    • /
    • pp.41-67
    • /
    • 1991
  • 본고(本稿)의 목적은 지방자치제(地方自治制)가 실시됨에 따라 국민경제(國民經濟)에 어떠한 파급효과를 미칠 것인가의 문제와 지방자치(地方自治)의 건실한 발전과 정착을 위해서 지방재정(地方財政)을 어떻게 운용할 것인가의 문제를 고찰하고자 함에 있다. 지방자치(地方自治)는 우리 경제의 지속적인 성장(成長)과 균형발전(均衡發展), 자원배분(資源配分)의 효율성 (效率性) 제고(提高)에 크게 기여할 것이나 경제적(經濟的)인 폐해(弊害)로서 단기적인 물가불안(物價不安), 조세경쟁(租稅競爭) 및 조세수출(租稅輸出)로 인한 자원배분(資源配分)의 비효율(非效率), 지방정부(地方政府)의 재정파탄(財政破綻) 등이 우려되는데 이에 대해서는 적절한 대응책이 강구되어야 한다. 일반적으로 지방자치(地方自治)의 경우 중앙집권(中央集權)의 경우보다 자원배분(資源配分)이 효율적(效率的)으로 이루어지나 본고(本稿) 제(第)III장(章)의 모형분석(模型分析)에서는 지방자치(地方自治)와 중앙집권(中央集權)의 상대적인 효율성(效率性)이 국가(國家) 지방공공재(地方公共財)의 대체탄력성(代替彈力性)의 크기에 의해서 결정되며 대체탄력성(代替彈力性)이 1보다 크면 오히려 중앙집권(中央集權)의 경우보다 효율적(效率的)인 자원배분(資源配分)이 이루어지는 결과가 나타난다. 지방자치(地方自治)의 건실한 발전은 다음과 같은 세가지 내용을 포함하는 지방재정(地方財政) 민주주의(民主主義)의 확립에 의해서 달성될 수 있다. (1) 중앙정부(中央政府)에 대한 지방정부(地方政府)의 자주적(自主的)인 재정권(財政權)이 확립되어야 하며 특히 중앙정부(中央政府)와 지방정부(地方政府)가 어느 정도 대등한 입장에서 합리적으로 운용(運用)할 수 있는 민주적(民主的)인 지방재정조정제도(地方財政調整制度)가 마련되어야 한다. (2) 지방재정운용(地方財政運用)에 있어서 주민(住民)들이 직접 예산편성(豫算編成)과 지역(地域)의 종합발전계획(綜合發展計劃)에 참여하는 직접민주주의(直接民主主義)가 활성화(活性化)되어야 하며 이를 위한 제1의 전제조건으로서 지방재정(地方財政)의 운용내용이 모든 주민(住民)들에게 공개되어야 한다. (3) 지방자치(地方自治)의 경제적(經濟的) 폐해(弊害)로서 가장 우려되는 지방정부(地方政府)의 재정파탄(財政破綻) 가능성에 대비하여 지방정부(地方政府)의 방만한 재정운용(財政運用)을 방지할 수 있는 제도적(制度的) 장치(裝置)로서 미국(美國) 등에서 시행되고 있는 주민(住民)이나 지방의회(地方議會)에 의한 여러가지 형태의 재정통제제도(財政統制制度)가 마련되어야 한다.

  • PDF

작업 준비비용 최소화를 고려한 강화학습 기반의 실시간 일정계획 수립기법 (Real-Time Scheduling Scheme based on Reinforcement Learning Considering Minimizing Setup Cost)

  • 유우식;김성재;김관호
    • 한국전자거래학회지
    • /
    • 제25권2호
    • /
    • pp.15-27
    • /
    • 2020
  • 본 연구는 일정계획을 위한 간트 차트(Gantt Chart) 생성과정을 세로로 세우면 일자형만 존재하는 테트리스(Tetris) 게임과 유사하다는 아이디어에서 출발하였다. 테트리스 게임에서 X축은 M개의 설비(Machine)들이 되고 Y축은 시간이 된다. 모든 설비에서 모든 종류(Type)의 주문은 분리 없이 작업 가능하나 작업물 종류가 다를 경우에는 시간지체 없이 작업 준비비용(SetupCost)이 발생한다는 가정이다. 본 연구에서는 앞에서 설명한 게임을 간트리스(Gantris)라 명명하고 게임환경을 구현 하였으며, 심층 강화학습을 통해서 학습한 인공지능이 실시간 스케줄링한 일정계획과 인간이 실시간으로 게임을 통해 수립한 일정계획을 비교하였다. 비교연구에서 학습환경은 단일 주문목록 학습환경과 임의 주문목록 학습환경에서 학습하였다. 본 연구에서 수행한 비교대상 시스템은 두 가지로 4개의 머신(Machine)-2개의 주문 종류(Type)가 있는 시스템(4M2T)과 10개의 머신-6개의 주문종류가 있는 시스템(10M6T)이다. 생성된 일정계획의 성능지표로는 100개의 주문을 처리하는데 발생하는 Setup Cost, 총 소요 생산시간(makespan)과 유휴가공시간(idle time)의 가중합이 활용되었다. 비교연구 결과 4M2T 시스템에서는 학습환경에 관계없이 학습된 시스템이 실험자보다 성능지표가 우수한 일정계획을 생성하였다. 10M6T 시스템의 경우 제안한 시스템이 단일 학습환경에서는 실험자보다 우수한 성능 지표의 일정계획을 생성하였으나 임의 학습환경에서는 실험자보다 부진한 성능지표를 보였다. 그러나 job Change 횟수 비교에서는 학습시스템이 4M2T, 10M6T 모두 사람보다 적은 결과를 나타내어 우수한 스케줄링 성능을 보였다.

원격탐사와 지리정보시스템을 이용한 시화지구 일대의 지표환경변화와 토공량 예측연구 (Geo-surface Environmental Changes and Reclaimed Amount Prediction Using Remote Sensing and Geographic Information System in the Siwha Area)

  • 양소연;송무영;황정
    • 지질공학
    • /
    • 제9권2호
    • /
    • pp.161-176
    • /
    • 1999
  • 해안매립의 적지로 선정된 시화지구 일대의 시화방조제와 안산신도시개발과 관련된 지표지형의 변화를 관측하기 위해 년도별 인공위성영상을 이용하였으며, 시화방조제 완공으로 노출된 간척지의 매립량을 분석하기 위하여 지리정보시스템을 이용하였다. 시화지구 일대의 인위적인 인간활동과 관련된 년도별 지형의 변화양상과 퇴적물의 분포양상, 산림의 토지피복상태, 그리고 변화된 토지피복현황을 관측하기 위해, 일반적으로 널리 이용되는 위성영상합성, Tasseled cap, 식생지수와 감독분류기법을 이용하였다 매립계획이 수립된 간척지의 매립량을 토목공사 이전에 추측하기 위하여 지질도, 시화간척지 조성계획도, 지상 DEM, 해저 DEM자료층을 지형도, 지질도, 해도, 시화지구 계획도면으로부터 추출하였다. 또한, 인공위성 영상자료 중 감독분류 영상을 분석하여 인근육지의 절취예상 가능위치를 추출하였다 해안선 및 연안지역의 지표지형변화 관측을 위한 처리기법 중 Tasseled cap으로 노출된 조간대의 퇴적물의 침식과 퇴적지역을 관찰하였고, 식생지수 기법으로 식생지수의 차이를 이용하여 산림피복 분포양상을 파악하였으며, 감독분류 영상으로부터 년도별 토지피복 변화현황을 관찰하였다. 수치지형분석으로 계산된 시화지구 간척지의 총매립량은 $581,485,354\textrm{m}^3$이고, 이를 호수공원 하부에서 준설할 경우 예상되는 최종 호수공원의 깊이는 9.2m이다. 또한, 계획단지 주변에 제방을 축조할 경우, 소요될 매립량은 $3,387,360\textrm{m}^3$이며, 이를 인근육지로부터 절취한다고 가정할 때, 선감도와 송산면일부, 대부도일부 예정지의 절취량은 각각 $5,229,576\textrm{m}^3,{\;}79,227,072\textrm{m}^3,{\;}47,026,008\textrm{m}^3$이다. 따라서, 제방 축조시 필요한 토공량은 대부도일부의 절취량만으로도 충분히 충당할 수 있음을 알 수 있었다.

  • PDF

측두하악장애환자에서 교합안정장치가 하악골위치변화에 미치는 영향에 관한 연구 (A study of mandibular positional changes by the stabilization splint in TMD patients)

  • 천훈;박영국;정규림
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.491-507
    • /
    • 2000
  • 이 연구는 측두하악장애 증상을 나타내는 부정교합자를 대상으로 교합안정장치 사용 전, 후의 측모 두부방사선 사진 상의 하악골의 위치변화를 구명하는데 그 목적이 있다. 연구의 대상자는 측두하악장애증상을 나타내는 부정교합자 60명이며 남자 19명, 여자 41명으로 각각의 평균연령은 19.5세와 21.5세 이었다. 전체 대상자를 전, 후방적으로는 Angle 분류법에 따른 교합관계에 의하여 Class I, II, III로 분류하였고, 수직적으로는 Jarabak의 후안면고경과 전안면고경의 비율에 따라서 clockwise, straight downward, counterclockwise의 3군으로 구분하여 부정교합군 별로 측정했으며 하악골의 위치변화를 중심교합시의 측모 두부방사선 사진 계측치들로부터 예측할 수 있는지 알아보기 위한 분석을 시행한 것으로 다음과 같은 결과를 얻었다. 1. 전체 대상자 비교시 측두하악장애를 갖는 부정교합환자에서 교합안정장치 사용 이후 하악골은 후하방 회전을 나타내었고 overjet은 1.3mm의 증가, overbite은 1.9mm감소되어 수평변화보다 수직적인 변화의 양이 컸다. 2. 전후방 3군 분류시 하악골의 후하방 변위를 나타내는 항목의 유의성 있는 변화는 Class II군에서 가장 현저하였으며 3군중 후방변위량이 가장 컸다. 3.수직 3군 분류시 Clockwise와 counterclockwise군에서 하악골의 후하방 변위를 나타내는 항목의 유의성 있는 변화가 뚜렷하였으며, 3군 모두에서 수직적인 변화량이 수평변화량 보다 컸다. 4. 중심교합위시의 부정교합 양태 및 골격유형, 그리고 중심교합위 계측치를 통하여 중심위 계측치를 설명할 수 있는 항목은 발견되지 않았다. 이상의 결과는 기존에 시행되어 오던 중심위 전환에 의한 방법이 아니고 측두하악장애를 갖는 부정교합자에서 교합안정 장치 를 장착하여 중심위를 획득한 상태에서 하악골의 위치 변화를 계측한 것으로 측두하악장애를 동반한 부정교합환자에서 중심교합위 상태의 측모 두부방사선 사진에 의존한 진단은 부정교합의 실체를 파악할 수 없음을 확인하였으며, 통상적으로 이용되어 온 중심위 전환방법 역시 중심위 유도후 발생되는 수직적인 부조화의 양상을 나타낼 수 없음을 입증하였다. 또한 전, 후방적으로는 Class II 부정교합군, 수직적으로는 Clockwise군과 Counterclockwise군에서 교합안정장치를 사용한 중심위 회복시에 하악골의 후하방 회전과 이에 동반된 구치부의 교합간섭으로 전후방 부조화뿐 아니라 수직적부조화를 더욱 심화시키므로 이에 대한 진단 및 치료시의 고려가 요구됨을 보여주었다.

  • PDF

지점우량 자료의 분포형 설정과 내용안전년수에 따르는 확률강우량에 관한 고찰 - 국내 3개지점 서울, 부산 및 대구를 중심으로 -

  • 이원환;이길춘;정연규
    • 물과 미래
    • /
    • 제5권1호
    • /
    • pp.27-36
    • /
    • 1972
  • 수공구조물의 계획이나 안전한 설계에 필요한 계획강우량으로서 확률강우량의 정확한 파악은 구조물의 내용년수와 결부시켜서 연구 검토되어야 할 문제라 생각되어 본 고에서는 국내 주요지점 가운데 3개지점(서울 부산 및 대구)의 24시간 이하의 강우량 자료를 기본자료로 취하여 해석한 내용이다. 본 연구의 주요내용을 약술하면 다음과 같다. 1. 기왕의 수문자료중 결측된 자료에 대한 보완 $\circled1$ Fourier Series Method. $\circled2$Trend Diagram Method $\circled3$ Mean Value Method. 상기 ${\circled1}{\circled2}{\circled3}$방법을 실시하여 산출한 치들 중에서 방화공학적인 면을 고려하여 최대치를 선택하여 결측된 자료를 보완하였다. 2. 자료의 통계치 산정 강우량자료를 Computer에 의하여 작은 것부터 크기 순위로 나열하고 이와같이 정리된 자료치를 log, $\sqrt{}, \sqrt[3]{}, \sqrt[4]$\sqrt[5]의 값으로 변환시켜 필요한 통계치를 산정하였다. 3. 분포형 검정과 최적분포형의 설정 $x^2-Test$에 의하여 분포형을 검정하고 자료의 기각을 행하여 이 결과에 의하여 최적분포형을 설정하였다. 4. 내용안전년수에 따르는 확률강우량 확률년(재현기간)과 내용안전년수와의 상관 관계를 고찰하여 내용안전년에 대한 확률강우량을 제시하였다. 결론적으로 지점별 및 강우계속 시간별로 강우량의 최적분포형을 선정하여 최적분포식을 설정하였다. 또한 안전율과 내용연수에 대한 확률강우량을 계산하여 표로서 제시하였다.제시하였다.했으며, 여러 가지 特殊染色法이 개발되어 사람의 染色體 하나 하나를 정확히 식별 할 수 있는 단계에 접어들게 되었다. 그중에서도 식별 할 수 있는 단계에 접어들게 되었다. 그중에서도 대표적인 것이 키나크린 螢光染色法(quinacrine fluorescence staining method)와 김자分染法(heat-giemsa staining method)이며 이들 방법을 통하면 染色體의 縱軸에 따라 특유한 明暗의 밴드 패턴(banding patterns)이 나타나게 되어, 사람만이 아니라 고등한 동물의 모든 染色體가 쉽게 同定이 된다는 것이다. 조파구간에는 초장에 큰 변이가 없었고 파종기가 늦어짐에 따라 짧아졌다. 초장의 신장속도는 파종기가 늦어짐에 따라 현저하게 빨라지고 특히 조생종이 만생종보다 더욱 가속적인 경향이었다. 따라서 최고초장과 최저초장과의 절대치의 차이는 조생종일수록 적고 만생종일수록 큰 격차를 보이었다. 6. 간직경에 있어서도 만생종은 일반적으로 조기파종할수록 굵고, 조생종과 중생종은 4월 25일 파종기가 가장 굵은 편이며 이보다 파종기가 지연 가늘어지는 경향이었다. 7. 간중은 품종의 조만생에 따라 약간의 차이는 있으나 대체로 적기(4월 25일~5월 15일)보다 조기 혹은 만기 파종하면 작아지나 파종기 이동에 따른 간중의 변화는 품종의 조만성에 따라 양상을 달리하여 조생종은 4월 25일 내외, 중생종은 4월 25일~5월 15일 내외, 만생종은 4월 5일~5월 15일 내외의 파종기에서 최고수량에 달하고 이후 직선적으로 감소하였다. 8. Brix 도는 품종에 따라 절대치가 다르며 또한 파종기가 5월 15일 이후로 늦어짐에 따라 직선적으로 감소되어 파종기(x)와 Brix 도(y) 간에 고도의 부상관관계를 볼 수 있었다. 9. 출수후 40~45일경의 절간부위별

  • PDF

긴급구조훈련 개선에 관한 의식조사 연구 -강원도 소방조직을 중심으로- (A Study on the Consciousness Survey of Improvement of Emergency Rescue Training -Based on the Fire Fighting Organizations in Gangwon Province-)

  • 최윤정;구원회;백민호
    • 한국재난정보학회 논문집
    • /
    • 제15권3호
    • /
    • pp.440-449
    • /
    • 2019
  • 연구목적 : 소방조직은 재난현장에서 가장 우선적으로 대응하는 기관으로 신속하고 체계적인 대응을 하기 위하여 긴급구조훈련을 실시하고 있다. 하지만 형식적인 훈련, 지역적 특성이나 환경적 특성이 고려되지 않는 훈련 등 긴급구조훈련의 한계점에 대한 변화와 개선의 필요성이 제기되고 있다. 연구방법 : 본 연구에서는 긴급구조훈련과 관련된 이론적 검토를 실시하고 강원지역 소방조직의 의식조사를 통하여 긴급구조훈련 개선방안을 제시하였다. 연구결과 : 긴급구조 활동 시 어려움이 있는 시설은 위험물 저장 및 처리시설이 가장 많았으며 긴급구조 대응업무의 수준은 응급복구가 미흡하다고 응답한 의견이 가장 많았다. 또한 긴급구조훈련의 효과는 도움이 된다고 응답하였지만 시나리오에 의한 훈련, 보여주기식 훈련, 매년 유사한 훈련, 현실감 없는 훈련, 유관기관의 관심 부족 및 형식적 참여 등으로 도움이 되지 않는다고 응답한 부분도 있었다. 그리고 긴급구조훈련 평가의 적절성은 대부분이 만족한다고 응답하였지만 훈련 유형과 상관없는 평가방식, 필요 이상의 훈련 규모를 설정하게 하는 평가방식, 유관기관의 형식적 참여를 유도하는 평가방식 등으로 만족하지 않는다고 응답하였다. 마지막으로 긴급 구조훈련 개선에 대한 요구도는 다양한 피해 상황을 반영한 훈련이 필요하다는 의견이 가장 많았다. 결론 : 긴급구조훈련 개선방안은 다음과 같다. 첫째, 다양한 훈련내용을 설정하고 지역의 주요 발생재난 등을 검토하여 지역적 특성에 맞게 작성해야 한다. 둘째, 소방서별 적절한 훈련계획을 위하여 긴급구조훈련계획 지침 및 매뉴얼 등을 개정하고 실무자를 대상으로 교육하고 이를 위해 긴급구조훈련에 대한 유형부터 전술, 전략까지 실무적으로 활용할 수 있도록 훈련을 정립해야 한다. 셋째, 실제 재난 발생 시 지원기관 및 유관기관의 참여도를 높이기 위하여 훈련계획단계부터 참여를 유도하고 인센티브 혹은 패널티(penalty)를 줄 수 있는 제도 등을 마련해야 한다. 넷째, 동시다발적으로 발생할 수 있는 재난 상황에 대비하여 소방서간, 권역별 훈련으로 기관별 지원태세 확립, 협조체계를 구축해야 한다. 다섯째, 긴급구조훈련 평가는 결과보다 훈련과정에 중점을 둘 수 있도록 하고 재난상황별 보완사항을 도출해내는데 관심을 두고 개선해야 한다. 특히, 세부절차에 수행여부를 평가하기 보다는 훈련의 종류나 형태 등을 고려하여야 하며 훈련 규모 보다는 훈련의 완성도(숙련도), 역할 수행여부 등을 고려할 수 있는 평가방안이 마련되어야 한다. 여섯째, 효율적인 긴급구조훈련을 위하여 실무자의 요구도를 파악하여 훈련 유형 및 방법에 대하여 소방서별 특성에 맞는 훈련으로 개선되어야 한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF