• 제목/요약/키워드: Planning CT

검색결과 463건 처리시간 0.023초

Value of FDG PET/Contrast-Enhanced CT in Initial Staging of Colorectal Cancer - Comparison with Contrast-Enhanced CT

  • Kunawudhi, Anchisa;Sereeborwornthanasak, Karun;Promteangtrong, Chetsadaporn;Siripongpreeda, Bunchorn;Vanprom, Saiphet;Chotipanich, Chanisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권8호
    • /
    • pp.4071-4075
    • /
    • 2016
  • Background: FDG PET/CT is at an equivocal stage to recommend for staging of colorectal cancer as compared to contrast-enhanced CT (ceCT). This study was intended to evaluate the value of FDG PET/ceCT in colorectal cancer staging as compared to ceCT alone. Materials and Methods: PET/ceCT was performed for 61 colorectal cancer patients who were prospectively enrolled in the study. Three patients were excluded due to loss to follow-up. PET/ceCT findings and ceCT results alone were read separately. The treatment planning was then determined by tumor board consensus. The criteria for T staging were determined by the findings of ceCT. Nodal positive by PET/ceCT imaging was determined by visual analysis of FDG uptake greater than regional background blood pool activity. The diagnostic accuracy of T and N staging was determined only in patients who received surgery without any neoadjuvant treatment. Results: Of 58 patients, there were 40 with colon cancers including sigmoid cancers and 18 with rectal cancers. PET/ceCT in pre-operative staging detected bone metastasis and metastatic inguinal lymph nodes (M1a) that were undepicted on CT in 2 patients (3%), clearly defined 19 equivocal lesions on ceCT in 18 patients (31%) and excluded 6 metastatic lesions diagnosed by ceCT in 6 patients (10%). These resulted in alteration of management plan in 15 out of the 58 cases (26%) i.e. changing from chemotherapy to surgery (4), changing extent of surgery (9) and avoidance of futile surgery (2). Forty four patients underwent surgery within 45 days after PET/CT. The diagnostic accuracy for N staging with PET/ceCT and ceCT alone was 66% and 48% with false positive rates of 24% (6/25) and 76% (19/25) and false negative rates of 47% (9/19) and 21% (4/19), respectively. All of the false negative lymph nodes from PET/ceCT were less than a centimeter in size and located in peri-lesional regions. The diagnostic accuracy for T staging was 82%. The sensitivity of the peri-lesional fat stranding sign in determining T3 stage was 94% and the specificity was 54%. Conclusions: Our study suggested promising roles of PET/ceCT in initial staging of colorectal cancer with better diagnostic accuracy facilitating management planning.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

각각의 방사선수술 치료계획시스템에 따른 동일 병변의 체적 차이 비교 (Differences in Target Volume Delineation Using Typical Radiosurgery Planning System)

  • 한수철;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.265-270
    • /
    • 2013
  • 방사선수술 치료계획 시 목표체적 윤곽 그리기 과정에서 발생하는 오차를 확인 하기 위하여 작은 목표체적을 고르게 분포시킨 두 경부 팬텀을 제작하였으며, 동일한 팬텀을 사용하여 CT영상 및 MR영상을 획득하고 이를 대표적인 3개의 방사선수술 치료계획시스템에서 작은 목표체적에 대하여 윤곽 그리기 한 후 체적을 측정하여 비교 분석하였다. CT로부터 획득한 이미지를 이용하여 BrainSCAN (노발리스)에서 윤곽 그리기를 하여 체적을 측정한 경우, 체적 평균값은 $2.23{\pm}0.08cm^3$이며, Leksell gamma plan (감마 나이프)은 $2.13{\pm}0.07cm^3$, Multi plan (사이버 나이프)에서 측정한 값은 $2.24{\pm}0.10cm^3$이였다. 또한 MRI로부터 획득한 이미지를 이용하여 BrainSCAN에서 윤곽 그리기를 하여 체적을 측정한 경우, 체적크기의 평균값은 $2.08{\pm}0.06cm^3$이며, Leksell gamma plan은 $1.94{\pm}0.05cm^3$이고 Multi plan에서 측정한 값은 $2.15{\pm}0.06cm^3$이었다. 각 방사선치료계획 시스템에서 CT영상과 MR영상으로부터 측정한 목표체적의 차이는 CT에서 획득한 이미지를 측정한 체적이 MRI보다 평균적으로 6.4% 정도 크게 나타나는 것을 확인하였다. 동일한 영상획득 장비에서 획득한 이미지를 3개의 서로 다른 방사선치료시스템에서 측정한 결과의 차이는 3~6%이었다. 이 결과는 영상을 획득하는 방식과 윤곽을 그릴 때 생기는 오차를 고려하였을 때 임상적으로 수용할 수 있는 범위 내에 들어간다고 판단이 된다.

흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究) (Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques)

  • 이주혁;고경환;하성환;한만청
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

치료보조기구의 제작 및 유용성 평가 (The evaluation of usefulness of the newly manufactured immobilization device)

  • 서석진;김찬용;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.45-55
    • /
    • 2005
  • 목적 : 최근의 방사선치료는 정상조직의 장애는 최대한 줄이고 종양조직 선량을 높여 치료효과를 극대화 하기위하여 3차원적으로 발전되어왔으며, 이에 따른 환자 체위고정을 위한 고정기구와 보조기구의 개발이 필수적으로 요구되고 있다. 본원에서는 MR head holder, 개방형 head holder, Plan CT couch plate를 자체 제작하여 그 유용성을 평가하고 분석하였으며, 임상에 적용한 결과를 보고하고자 한다. 대상 및 방법 : MR head holder를 제작하여 진단 MR영상과 치료계획용 MR영상을 CT영상과 fusion하여 두 영상의 일치성과 정확성을 분석하였고, 개방형 head holder를 제작하여 피부선량과 선량감약 정도를 알아보았으며, 6 mm 아크릴판에 스티로폼을 부착하는 CT couch plate를 제작하여 hard plate와 artifact 정도를 비교하였다. 결과 : Head holder를 사용하지 않은 fusion영상보다 2 mm이내의 오차로 정확한 fusion을 할 수 있었고, 개방형 head holder를 사용함에 따라 피부선량을 최대 2배 이상 줄일 수 있었고, $20\%$이상 선량이 감약되는 것을 최소화할 수 있었다. Plan CT couch plate를 사용했을 때는 2단 연결, 부착 식으로 제작하여 사용이 간편하고 artifact를 현저하게 줄일 수 있었다. 결론 : MR 영상에서도 기준 좌표점을 확인할 수 있어 정확한 MR / CT fusion을 시행할 수 있었고, 향후 PET, 초음파 영상의 fusion도 연구되어야 할 것으로 사료되며, 이에 따른 고정기구의 개발도 필수적이라 할 수 있겠다. 개방형 head holder를 사용함으로써 피부선량과 선량 감약을 감소시킬 수 있었다. 이러한 치료보조기구를 자체 제작하여 고가의 외국상품을 대체할 수 있어 비용은 절감할 수 있었지만 견고성에서는 떨어지므로 가볍고 선량 감약이 적으며 강도가 강한 특수 재질의 치료보조기구가 개발되어야 할 것으로 사료된다.

  • PDF

승모판막수술 및 중재술을 위한 전산화단층영상 (CT Imaging for Mitral Valve Surgery and Intervention)

  • 양동현
    • 대한영상의학회지
    • /
    • 제81권2호
    • /
    • pp.290-301
    • /
    • 2020
  • 최근 들어 승모판(mitral valve) 질환에 대해 승모판 성형술(mitral valvuloplasty) 또는 중재 시술을 통하여 인공판막을 넣어주는 시술(transcatheter mitral valve replacement)이 발전하고 있다. 이러한 치료 계획을 위해서는 승모판의 해부학적인 정보를 수술자 혹은 시술자의 관점에서 조금 더 자세하게 알려줄 필요가 있다. 본 리뷰에서는 승모판의 보존 수술 및 중재적 시술의 치료 전 계획을 위한 승모판의 해부학 및 CT를 이용한 승모판막 주변의 평가 방법에 대해 다루고자 한다.

중이 손상의 고해상 CT 평가 (High Resolution CT Evaluation of the Middle Ear Injury)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권3호
    • /
    • pp.13-18
    • /
    • 2004
  • 고해상 측두골 CT소견상 안면신경관의 변화를 분석하여 안면신경관의 불연속성 뿐 아니라 신경관의 전이나 골편 등 안면신경관을 직접 침범하는 소견과 직접 안면신경관의 손상은 없으나 신경관이 확장되어 보이거나 인접부위에 골절을 보이는 간접소견을 관찰할 수 있었다. 난청, 현훈 그리고 안면신경마비의 경우 CT만으로 원인 병변을 규명하는 것은 한계가 있어 이 경우 임상소견과의 비교는 필수적이며 본 연구에서는 고해상 CT의 이상소견이 비교적 정확한 것으로 나타났다.

  • PDF

CT 영상을 이용한 불균질 조직의 선량보정 평가 (Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image)

  • 김가중
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 목 적: 방사선치료에 있어 종양조직이나 정상조직의 정확한 선량계산은 치료의 성패를 좌우하는 가장 큰 요인이다. 이로 인해 방사선치료계획은 컴퓨터 단층 영상의 재구성을 통한 불균질 조직에 선흡수계수를 밀도로 변환하여 CT 번호에 의한 선량 보정이 유효하게 이루어지고 있다. 대상 및 방법: 이에 본 연구는 불균질 조직등가 팬톰을 제작하여 현재 사용 중인 방사선 치료 계획시스템을 이용한 CT 번호의 측정과 질량밀도를 계산하여 물을 기준으로 상대값을 구하였다. 또한 실제 방사선 조사 시 측정된 선량(nC)과 CT영상을 이용한 치료계획 시 선량(PDD)을 상대적으로 비교함으로써 실제 CT 번호를 이용한 불균질 조직의 보정에 대한 유용성과 정확성을 평가하고자 한다. 결 과: 측정결과 CT 번호를 이용하여 계산된 조직등가물질의 질량밀도와 실제 질량밀도는 $0.005{\sim}0.069g/cm^3$의 차이를 보였으며, 방사선 치료계획 시 심부선량(PDD)과 방사선 치료 장치로 조사하여 측정된 선량의 상대오차는 $-2.8{\sim}+1.06%$로 3% 이내의 유효범위이내의 결과를 얻었다. 결 론: 본 실험은 CT 영상을 이용한 불균질 조직의 보정에 대한 유용성을 확인할 수 있었고, 방사선 치료 계획 장치의 정도 관리(Quality Assurance; QA)의 기본 틀을 제공할 수 있을 것으로 사료된다.

  • PDF

유방암에서 CT planning를 이용한 치료계획 (Radiotherapy Treatment Planning using Computed Tomography in Breast Cancer)

  • 김성규;신세원;김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.59-65
    • /
    • 1992
  • 유방암은 여성암 가운데 세계에서 가장 빈도가 높으며, 한국에서도 세번째로 많은 것으로 보고하고 있다. 유방암에서 방사선치료는 photon beam를 이용하여 tangential field로 치료하거나 electron beam를 이용하여 치료하는 것이 보편적이다. 치료범위 내부의 밀도와 tumor까지의 깊이는 방사선치료에서 선량분포를 결정하는 중요한 요소들이다. CT planning를 이용하면 이러한 요소들을 정확하게 산출하여 선량과 선량분포를 결정하는데 이용할 수 있다. 저자들이 유방암 환자 65명중 전자선으로 치료를 받은 45명을 분석한 결과 cheast wall의 두께와 internal mammary lyphnode의 깊이가 1.5cm 이하인 경우에는 6MeV의 에너지가 적적함을 보여 주었으며, 1.5cm에서 2.0cm까지는 9MeV의 에너지가, 2.0cm에서 2.5cm까지는 12MeV의 에너지가 적절함을 보였다.

  • PDF

비전형적인 심하복벽동맥의 주행을 파악하기 위한 수술 전 CT Angiography의 유용성 (Atypical Patterns of Deep Inferior Epigastric Artery: Clinical Implication of Preoperative CT Angiography)

  • 이택종;김성찬;엄진섭;김은기
    • Archives of Reconstructive Microsurgery
    • /
    • 제21권1호
    • /
    • pp.8-13
    • /
    • 2012
  • Purpose: Purpose: The free deep inferior epigastric artery perforator (DIEP) flap is a popular option for autologous breast reconstruction. However, the anatomy of the deep inferior epigastric artery(DIEA) may vary from one individual to another. Unexpected vascular anomaly can confuse the surgeon and affects on the safety of the free DIEP flap. Materials and Methods: Thirty five consecutive patients who underwent free DIEP/TRAM flap for immediate breast reconstruction between Mar. 2010 and Oct. 2010 were enrolled in this study. Computed tomography angiography (CT angiography) of abdomen was evaluated part of our standard preoperative assessment: atypical patterns of DIEA/DIEP were evaluated by preoperative CT angiography and compared with intraoperative finding. Results: Atypical patterns of DIEA/DIEP which may affect preoperative planning were noted as the following: Circummusclar/subfascial DIEA (n=1), DIEA running underneath rectus muscle (n=8), septocutaneous perforator (n=3), peritoneo-cutaneous perforator (n=1), a large branch going into peritoneum (n=1), and very early division and muscle penetration of DIEA (n=1). Conclusion: Atypical DIEA/DIEP that might change the operation plan is not rare, so the individualized planning based on the preoperative CT angiography is recommended. Preoperative CT angiography could help to select reliable and easy-to-dissect perforator in free DIEP/TRAM breast reconstruction.

  • PDF