  • The piled-raft foundation, a new design concept, is one of the most effective kinds of foundation for reducing settlement of structures. An alternative piled-raft system with disconnection cap and a sand cushion between the pile and raft was also investigated to compare the influence of ultimate bearing capacity and settlement. Load-settlement relation curves were used to evaluate the ultimate bearing capacity. In the numerical analyses, a plane strain elasto-plastic finite element model (Mohr-Coulomb model) was used to present the response of the piled-raft foundation.

25MW급 산업용 가스터빈의 저널과 베어링 손상 보수사례에 관한 연구 (A Study on Repair Case of Journal and Bearing Damage for 25MW Industrial Gas Turbine)

  • 김병옥;선경호;이안성
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.64-69
    • /
    • 2012
  • This paper deals with the study on repair case of journal shaft and bearing damage in 25MW industrial gas turbine caused by sudden blackout, operation mistake, and logic abnormal, etc. When a serious accident such as journal and bearing damage in a gas turbine occurs, the domestic local companies having the gas turbine are dependent on manufacturer for all maintenance and repair schedule until now. This case study shows that the damaged gas turbine is normally re-operated itself in domestic by establishing repair schedule in a short period of time, repairing damage journal shaft and tilting pad bearings, and performing rotating test for a reliability check. This paper can be regarded as the important case study of emergency test run experience of the refurbished 25MW gas turbine rotor.

High Out-of-Plane Alignment of Liquid Crystalline Methacrylate Copolymer Bearing Photoreactive 4-Styrylpyridine Moiety

  • Kwak, Gi-Seop;Kong, Jong-Yun;Kim, Min-Woo;Hyun, Seok-Hee;Kim, Woo-Sik
    • Macromolecular Research
    • /
    • 제17권4호
    • /
    • pp.271-275
    • /
    • 2009
  • This paper describes the out-of-plane order of a liquid crystalline(LC) methacrylate copolymer(3) comprised of a methacrylate(1) with a 4-styrylpyridine moiety as the photo-cyclodimerizable group and a benzoate moiety as the mesogenic group in the side chain, and another methacrylate(2) with a 4-(4-methoxyphenyl)benzoate moiety as the mesogenic group. The composition of 1 and 2 units in 3 was estimated to have a molar ratio of 54.2:45.8 by $^{1}H$ NMR spectroscopy. The X-ray diffraction study revealed that the copolymer forms a partial bilayer smectic structure. The copolymer gave rise to a high out-of-plane order parameter of about 0.74 in a wide LC temperature range of $110{\sim}160^{\circ}C$ after linearly polarized, UV light irradiation and subsequent annealing. Moreover, the external reflection IR analysis indicated that excess UV-light irradiation makes the out-of-plane LC structure of the copolymer appear in a higher and wider temperature range.

Polyelectrolyte Micropatterning Using Agarose Plane Stamp and a Substrate Having Microscale Features on Its Surface

  • Lee, Min-Jung;Lee, Nae-Yoon;Lee, Sang-Kil;Park, Sung-Su;Kim, Youn-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1539-1542
    • /
    • 2005
  • We have introduced polyelectrolyte micro-patterning technique employing agarose plane stamp and a hard substrate having microscale features on its surface. With this method, chemically micropatterned surfaces with both positive and negative functionalities were successfully embedded in well-defined microstructures, and selective impartment of charge functionalities was confirmed by patterning bead bearing surface charge. Furthermore, this technique allows highly sensitive immobilization of protein onto targeted surface simply by endowing functionalities, which extends the potential of its use as a tool for high-throughput protein microarray and proteomics. Because plane agarose stamp is free of structures on its surface, there is no concern for pattern collapse, and the combination of agarose plane stamp with patterned substrate is more suited for selective protein patterning compared with adopting surface-patterned agarose stamp with flat substrate. Our technique using agarose plane stamp and a substrate having microscale features on its surface suggests a range of possible applications, including the micropatterning of biofunctionalized copolymer having polyelectrolyte block, immobilization of micro- and nanoparticle with biofunctionalities such as biotin and streptavidine, and establishing optoelectronic microstructures with micro-beads on various surfaces.

첨단복합재료 적층판의 볼트단일접합 강도 시험적 평가 (Experimental Assessment of Bolted Single Lap Joint Strength for Laminates in Advanced Composite Materials)

  • 이명건;이정원;윤동현;김재훈
    • 대한기계학회논문집A
    • /
    • 제41권10호
    • /
    • pp.983-989
    • /
    • 2017
  • 본 논문에서는 첨단복합재의 볼트단일접합 베어링강도에 대한 시험적 평가 결과를 수록하였다. 볼트단일접합 시험은 stabilized 접합과 unstabilized 접합에 대하여 수행하였다. Stabilized 접합은 접합부 면외회전을 제한하는 접합이다. Unstabilized 접합은 면외변위를 제한하지 않는 접합이다. 볼트 단일접합에서 적층판의 베어링강도 값은 적층판 내 적층각 $0^{\circ}$, $+45^{\circ}$, $-45^{\circ}$$90^{\circ}$ 비율에 영향이 없음을 보여준다. 볼트접합부 면외거동의 영향으로 unstabilized 볼트 단일접합 베어링 강도값이 stabilized 볼트 단일접합 베어링 강도값 보다 작음을 보여주고 있다. 본 논문에 사용된 복합재료는 $177^{\circ}C(350^{\circ}F)$에서 경화되는 Carbon/Epoxy UD Tape 프리프레그이다. 표준각 $0^{\circ}$, $+45^{\circ}$, $-45^{\circ}$$90^{\circ}$ 층으로 적층된 8종류의 적층판에서 총 112개 볼트단일접합 시험시편을 구성하였다. Stabilized 접합과 unstabilized 접합의 시험방법은 ASTM-D-5961M 규정을 사용하였다.

Square footing on geocell reinforced cohesionless soils

  • Biswas, Sefali;Mittal, Satyendra
    • Geomechanics and Engineering
    • /
    • 제13권4호
    • /
    • pp.641-651
    • /
    • 2017
  • Ground improvement with use of geosynthetic products is globally accepted now. The present paper discusses the improvement in bearing capacity of square footing placed at surface of cohesionless soil reinforced with geocell. Mohr-Coulomb failure criterion has been used in the observations. To study effects of geocell with respect to planar geogrid, model tests were conducted on planar reinforcement also. A comparative study of unreinforced soil and soil reinforced with plane geogrid and geocell has also been made. Numerical analysis results obtained by PLaxis have been compared with those obtained from model tests and were found to be in good agreement. A parametric study revealed the role of length of reinforcement, spacing between layers, placement of reinforcement from top surface etc. on bearing capacity. A design example given in paper illustrates the savings in cost of construction of footing on reinforced sand. The study shows that there is improvement in bearing capacity with respect to unreinforced soil which is of the order of 86%. Similarly settlement reduction is 13.07% for single layer of geocell which for double layers of geocell is 693% and 86.48% respectively. The cost reduction in case of reinforced soil is 35% as compared to unreinforced soil.

헬리컬 기어의 축방향 가진에 의한 축-베어링-플레이트계의 방사소음 예측 (Prediction of Radiated Noise From a Shaft-bearing-plate System Due to an Axial Excitation of Helical Gears)

  • 박찬일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.199-203
    • /
    • 2004
  • In this paper, a simplified model is studied to predict analytically the radiated noise from the helical gear system due to an axial excitation of helical gear. The simplified model describes gear, shaft, bearing, and housing. To obtain the axial force of helical gear, mesh stiffness is calculated in the load deflection relation. The axial force is obtained from the solution of the equation of motion, using the mesh stiffness. It is used as a longitudinal excitation of the shaft, which in turn drives the gear housing through the bearing. In this study, the shaft is modeled as a rod, while the bearing is modeled as a parallel spring and damper only supporting longitudinal forces. The gear housing is modeled as a clamped circular plate with viscous damping. For the modeling of this system, transfer function from the shaft to the clamped plate are used, using a spectral method with four pole parameters. Out-of-plane displacement for the thin circular plate with viscous damping is derived and sound pressure radiated from the plate is also derived. Using the model, parameter studies are carried out.

  • PDF

필로티형 저층 내력벽주택의 내진설계 고려사항 (Considerations for Seismic Design of Low-Rise Residential Bearing Wall Buildings with Pilotis)

  • 이승제;엄태성
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.31-42
    • /
    • 2019
  • In this study, the results of an analytical investigation on the seismic behavior of two residential 4-story bearing wall buildings with pilotis, each of which has symmetric or unsymmetric wall arrangement at their piloti level, are presented. The dynamic characteristics and lateral resistance of the piloti buildings were investigated through linear elastic and nonlinear static analyses. According to the results, the analytical natural period of vibration of the piloti buildings were significantly shorter than the fundamental period calculated in accordance with KBC 2016. In the initial elastic behavior, the walls resisting in-plane shear contributed to the lateral stiffness and strength, while the contribution of columns resisting flexural moments in double curvature was limited. However, after the shear cracking and yielding of the walls occurred, the columns significantly contributed to the residual strength and ductility. Based on those investigations, design recommendations of low-rise bearing wall buildings with piloti configuration are given.

제2 중족 족지 및 중족 설상 관절의 관절염에 대한 방사선학적 분석 (Radiological Analysis of Osteoarthritis of the Second Metatarsophlangeal and Tarsometatarsal Joint)

  • 김정래;김성윤;이우천
    • 대한족부족관절학회지
    • /
    • 제16권2호
    • /
    • pp.101-107
    • /
    • 2012
  • Purpose: The aim of this study was to investigate the radiological characteristics of the osteoarthritis of the second metatarsophalangeal (MTP) and tarsometatarsal (TMT) joint. Materials and Methods: Between January 2002 and August 2010, 27 patients (33 feet) who had second metatarsal osteoarthritis (OA) were reviewed retrospectively. Group 1 was 14 patients (17 feet) with second MTP joint OA. Group 2 was 13 patients (16 feet) with second TMT joint OA. Group 3 was 24 patients (25 feet) had hallux valgus without second metatarsal (MT) OA as control. Weight bearing foot anteroposterior (AP) and lateral view were checked, and measured hallux valgus angle, metatarsus adductus angle (MAA), second MT functional length, first and second MT length by Hardy & Clapham method on AP view, angle of second MT with horizontal plane, calcaneal pitch, talo-first MT on lateral view. Results: On weight bearing foot AP view, second MT functional length of group 1, 2, 3 was 2.4 mm, -0.1 mm, 0.7 mm and MAA of group 1, 2, 3 was $17.7^{\circ}$, $17.7^{\circ}$, $14.5^{\circ}$. Second MT functional length of group 1 was longer than control group and it was statistically significant. MAA was significant different between group 1-3 and group 2-3. Angle of second MT with horizontal plane of group 2 was smaller than control group and it was statistically significant. Other radiographic parameters have no statistical significance. Conclusion: Group 1 has long functional length of second MT and group 2 has small angle of second MT with horizontal plane.

기초지반의 지지력보강공법에 관한 연구 (Studies on the Development of Bearing Capacity Reinforcement for the Foundation of Soil)

  • 유동환;최예환;유연택
    • 한국농공학회지
    • /
    • 제30권1호
    • /
    • pp.38-49
    • /
    • 1988
  • This paper presented as follows results of laboratory model tests with various shaped footings on soil bed reinforced with the strips on the base of behaviour of soil structure according to the loads and triaxial test results reinforced with geotextiles. Their parameters studied were the effects on the bearing capacity of a footing of the first layer of reinforcement, horizontal and vertical spacing of layers, number of layers, tensile strength of reinforcement and iclination load to the vertical 1.Depending on the strip arrangement, ultimate bearing capacity values could be more improved than urreinforced soil and the failure of soil was that the soil structure was transfered from the macrospace to microspase and its arrangement, from edge to edge to face to face. 2.The reinforcement was produced the reinforcing effects due to controlling the value of factor of one and permeable reinforcement was never a barrier of drainage condition. 3.Strength ratio was decreased as a linear shape according to increment of saturation degree of soil used even though at the lower strength ratio, the value of M-factor was rot influenced on the strength ratio but impermeable reinforcement decreased the strength of bearing capacity. 4.Ultimate bearing capacity under the plane-strain condition was appeared a little larger than triaxial or the other theoretical formulars and the circular footing more effective. 5.The maximum reinforcing effects were obtained at U I B=o.5, B / B=3 and N=3, when over that limit only acting as a anchor, and same strength of fabric appeared larger reinforcing effects compared to the thinner one. 6.As the LDR increased, more and more BCR occurred and there was appeared a block action below Z / B=O.5, but over the value, decrement of BCR was shown linear relation, and no effects above one. 7.The coefficient of the inclination was shown of minimum at the three layers of fabrics, but the value of H / B related to the ultimate load was decreased as increment of inclination degree, even though over the value of 4.5 there wasn't expected to the reinforcing effects As a consequence of the effects on load inclination, the degree of inclination of 15 per cent was decreased the bearing capacity of 70 per cent but irnproved the effects of 45 per cent through the insertion of geotextile.

  • PDF