• Title/Summary/Keyword: Planar.

Search Result 3,659, Processing Time 0.034 seconds

Development of Nonlinear Triangular Planar Element Based on Co-rotational Framework (Co-rotational 이론 기반 비선형 삼각평면 유한요소의 개발)

  • Cho, Hae-Seong;Shin, Sang-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.485-490
    • /
    • 2015
  • This paper presents development of a geometrically nonlinear triangular planar element including rotational degrees of freedom, based on the co-rotational(CR) formulation. The CR formulation is one of the efficient geometrically nonlinear formulations and it is based on the assumptions on small strain and large rotation. In this paper, modified CR formulation is suggested for the developemnt of a triangular planar element. The present development is validated regarding the static and time transient problems. The present results are compared with the results predicted by the previous researchers and those obtained by the existing commercial software.

Design of a compact and broadband PIFA using an additive short-circuit plate (추가 단락판을 이용한 소형 및 광대역 특성의 PIFA(Planar Inverted F Antenna) 설계)

  • 오경진;한영태;최재훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.591-597
    • /
    • 2003
  • In this paper, a compact and broadband PIFA(Planar Inverted F Antenna) which has an additive short-circuit plate along the patch length was designed. For more compact PIFA short-circuit Plate along the patch width is reduced and an additive short-circuit plate along the patch length is used to broaden the bandwidth. The effect of an additive-short-circuit plate along the patch length was verified in single band PIFA and also verified in dual-band PIFA. The commercial software, IE3D, was used to design a PIFA and its performance was verified by comparing simulated results with measurement results.

Fabrication and Test of Micro Direct Methanol Fuels using Platinum Sputtered Microcolumn Electrodes with a Limited Fuel Source (백금 촉매가 증착된 미소돌기 전극과 유한 연료를 가지는 극소형 직접메탄을 연료전지의 제작 및 성능 평가)

  • 서영호;조영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.218-224
    • /
    • 2004
  • We present a miniature Direct Methanol Fuel Cell (micro-DMFC) using platinum sputtered microcolumn electrodes with a limited amount of fuel. We use the microcolumn electrode in order to improve the power density of the micro-DMFC that consists of two electrodes and polymer electrolyte. We also design the built-in fuel chamber in the anode for the portable electronics applications. We design and fabricate both microcolumn and planar electrodes, having an identical projective area of 5mm${\times}$5mm. The diffusion current density of the microcolumn electrode is 1.73 times higher than that of the planar electrode at electrode potential of 1.1V in the half-cell test. The micro-DMFC based on the microcolumn electrodes shows the maximum power of 10.8$\pm$7.54㎼(43.23$\pm$0.16㎼/$\textrm{cm}^2$) at the projective area of 5mm${\times}$5mm, while the planar electrode micro-DMFC shows the maximum power of 0.81$\pm$0.42㎼(3.24$\pm$1.68㎼/$\textrm{cm}^2$) at the same projective area. The micro-DMFC based on the microcolumn electrodes shows 13 times higher power density that the micro-DMFC based on the planar electrodes does.

Simplified planar model for damage estimation of interlocked caisson system

  • Huynh, Thanh-Canh;Lee, So-Young;Kim, Jeong-Tae;Park, Woo-Sun;Han, Sang-Hun
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.441-463
    • /
    • 2013
  • In this paper, a simplified planar model is developed for damage estimation of interlocked caisson systems. Firstly, a conceptual dynamic model of the interlocked caisson system is designed on the basis of the characteristics of existing harbor caisson structures. A mass-spring-dashpot model allowing only the sway motion is formulated. To represent the condition of interlocking mechanisms, each caisson unit is connected to adjacent ones via springs and dashpots. Secondly, the accuracy of the planar model's vibration analysis is numerically evaluated on a 3-D FE model of the interlocked caisson system. Finally, the simplified planar model is employed for damage estimation in the interlocked caisson system. For localizing damaged caissons, a damage detection method based on modal strain energy is formulated for the caisson system.

Optical Temperature Sensor Based on the Etched Planar Waveguide Bragg Grating Considering Linear Thermo-optic Effect (평면 광도파로 상의 식각 브래그 격자를 이용한 광온도 센서의 개발)

  • Kook-Chan Ahn;Sang-Mae Lee
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2001
  • This paper demonstrates the development of optical temperature sensor based on the etched planar waveguide Bragg grating. Topics include design and fabrication of the etched planar waveguide Bragg grating, investigation of the grating reflection characteristics, and temperature measurement capabilities. The typical bandwidth and reflectivity of the surface etched grating has been ~0.2nm and ~7%, respectively, at a wavelength of ~1552nm. The temperature-induced wavelength change of the optical sensor is found to be slightly non-linear over ~20$0^{\circ}C$ temperature range. Theoretical models for the grating response of the sensor based on waveguide and plate deformation theories agree with experiments to within acceptable tolerance.

  • PDF

Scattering Parameter-based Measurement of Planar EMI filter

  • Wang, Shishan;Gong, Min;Xu, Chenchen
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.806-813
    • /
    • 2014
  • Planar electromagnetic interference (EMI) filters are widely used to restrain the conducted EMI of switching power supplies. Such filters are characterized by small size, low parasitic parameters, and better high-frequency performance than the passive discrete EMI filter. However, EMI filter performance cannot be exactly predicted by using existing methods. Therefore, this paper proposes a method to use scattering parameters (S-parameters) for the measurement of EMI filter performance. A planar EMI filter sample is established. From this sample, the relationship between S-parameters and insertion gain (IG) of EMI filter is derived. To determine the IG under different impedances, the EMI filter is theoretically calculated and practically measured. The differential structure of the near-field coupling model is also deduced, and the IG is calculated under standard impedance conditions. The calculated results and actual measurements are compared to verify the feasibility of the theory.

The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings (6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계)

  • Lim, Kwang-Jin;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

An Experimental Study on the Curing and Temperature History of Cold Weather Concrete by Planar Surface Heater (전기발열시트에 의한 한중콘크리트의 양생 및 온도이력에 관한 실험 연구)

  • Kim, Hyung-Rae;Cho, Ho-Kyu;Kim, Chan-Soo;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.135-139
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete cured with heating sheets in the laboratory conditions. As the results, It was showed that the 130W/$m^2$-heater could raise the inner temperature more than $20^{\circ}C$ under the environmental condition of -5~$-20^{\circ}C$. And the temperature of concrete cured by the 200W/$m^2$-heater was 5~$10^{\circ}C$ higher than that of concrete cured by 130W/$m^2$-heater. Finally, through the curing by the planar surface heater during the first 1.5~2 days, it is possible to secure the sufficient maturity of concrete.

A Study on the Design and Fabrication for Partial Discharge Measurment in 22.9kV Underground Power Cable using Planar Loop Sensor (22.9kV급 지중전력케이블의 부분방전 측정을 위한 평면루프센서 설계 및 제작 연구)

  • Shin, Dong-Hoon;Lim, Kwang-Jin;Lwin, Kyawsoe;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.210-211
    • /
    • 2007
  • The objective of this paper is to effectively detect partial discharges in underground power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar loop types for underground power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Loop Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

A Study on a Planar Folded RFID Reader Antenna by Minimizing Hand Effects For UHF Band Application (Hand effect를 최소화한 평판 격자형 UHF대역 RFID 리더 안테나에 관한 연구)

  • Park, Joung-Geun;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.80-85
    • /
    • 2012
  • In this paper, a new planar folded UHF band RFID reader antenna is suggested. For the antenna suggested in this paper, 4 PIFA (Planar Inverted F Antenna) micro-strip structures are adopted. The size is $50mm{\times}50mm{\times}6.2mm$. The gain of the antenna is 1.1 dBi, the VSWR is 1.2:1, and the efficiency is 63.3 %. The radiation pattern is designed as upper direction. Identification distance for the RFID tags is improved by minimizing hand effects with properly integrating 4 PIFAs.