• Title/Summary/Keyword: Plan Variation

Search Result 323, Processing Time 0.023 seconds

Reconstruction with Anterolateral Thigh Free Flap in Substitute for Radial Forearm Free Flap with Vascular Variation (유리전완피부피판의 혈관변이로 인해 전외측 대퇴유리피판을 대체 적용한 구강 내 재건 증례)

  • Yoon, Sang-Yong;Kim, Sung-Hee;Song, Jae-Min;Lee, Ju-Min;Nam, Su-Bong;Kim, Uk-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.4
    • /
    • pp.248-255
    • /
    • 2013
  • Reconstruction techniques of orofacial defects caused by wide excision of the intraoral malignant lesions are various. Although radial forearm free flap is a common donor site on reconstruction of soft tissue defect, anterolateral thigh (ALT) free flap also has an established site in orofacial soft tissue reconstruction as the favored donor flap with recent progress of the microsurgical technique. A 59-year-old female complained of hyperplastic mass on the right retromolar and buccal cheek, which was diagnosed as a squamous cell carcinoma (SCC) by an incisional biopsy. Before the operation, we planned a wide excision of the SCC lesion, supraomohyoid neck dissection, reconstruction with radial forearm free flap (RFFF), and split thickness skin graft. We accidentally found an arterial variation of the forearm area during elevation of RFFF, and changed the plan of reconstruction operation to reconstruction with ALT free flap. Operative sites was healed well during the post-operative period, and we referred to the department of radiation oncology for post-operative radiotherapy.

A Study on The Regional Variation of Hypertension Medication Rate (고혈압 약물치료율의 지역 간 변이에 관한 연구)

  • Seok, Hyang-Sook;Kang, Sung-Hong
    • Journal of Digital Convergence
    • /
    • v.11 no.9
    • /
    • pp.255-265
    • /
    • 2013
  • The purpose of this study was to identify the variation factors of hypertension medication rate between regions and to use them as a basic data for establishment of hypertension management business plan which is customized by region. The data were collected from community health survey, National Statistics Office and National Health Insurance Corporation, and were analyzed using the geographically weighted regression. As the result of analysis, the factors that influenced the hypertension medication rate between regions were subjective recognition rate of health level, the rate of medical aid client and the number of health facility per one hundred thousand of population. According to the geographically weighted regression, the total of 230 regional regression models composed of major variables which affected the hypertension medication rate were calculated. However, this study has several limitations that the explanatory power of model is not high and others. Therefore, a follow-up study which is based on the actual data of compliance with hypertension medication will be necessary.

Variation of Harbor Oscillations in Yeongil Bay

  • Jeon, Min-Su;Lee, Joong-Woo;Jeong, Jae-Hyun;Yang, Sang-Yong;Jeong, Young-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.53-58
    • /
    • 2006
  • Today, harbor oscillation problems are the most significant factor to consider when designing harbors serving very large ships. In coastal harbors, large vessels moored in the elastic hawsers are often displaced due to the resonance between long period waves and mooring systems. As a result, cargo handling may be interrupted and the hawsers may be broken, especially when the amplification becomes extreme. The most significant harbor confronted with harbor oscillation problem in Korea is Pohang New port. Many cases of problems are being reported by the pilot association and the local office of MOMAF (Ministry of Maritime Affairs and Fisheries). However, it is difficult to prevent the arrival of long waves causing oscillation within this harbor. Moreover, the Korean government has already started a new port plan at the mouth of Yeongil Bay without addressing the problems that have occurred in Pohang New port. This study deals with the variation of harbor oscillation due to the construction of a 4.1 km breakwater at the bay mouth including the arrangement of the new berths. Numerical methods used are in fairly standard form from the extended mile slope equation. The obtained numerical results were compared with field measurement from the previous and this will bring a certain level of discussion and consideration of variation to the future port development.

  • PDF

Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

  • Hyeongmin Jin;Hyun Joon An;Eui Kyu Chie;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 2022
  • Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air cavity in magnetic resonance-guided radiotherapy (MRgRT) for patients with pancreatic cancer. Methods: This study included nine patients that previously received MRgRT and their simulation CT and magnetic resonance (MR) images were collected. Air cavities were manually delineated on simulation CT and MR images in the treatment planning system for each patient. The synthetic CT images were generated using the deep learning model trained in a prior study. Two more plans with identical beam parameters were recalculated with ED maps that were either manually overridden by the cavities or derived from the synthetic CT. Dose calculation accuracy was explored in terms of dose-volume histogram parameters and gamma analysis. Results: The D95% averages were 48.80 Gy, 48.50 Gy, and 48.23 Gy for the original, manually assigned, and synthetic CT-based dose distributions, respectively. The greatest deviation was observed for one patient, whose D95% to synthetic CT was 1.84 Gy higher than the original plan. Conclusions: The variation of the air cavity position in the gastrointestinal area affects the treatment dose calculation. Synthetic CT-based ED modification would be a significant option for shortening the time-consuming process and improving MRgRT treatment accuracy.

Design of SPOKE Type BLDC Motor for Traction Application Considering Irreversible Demagnetization of Permanent Magnet

  • Hur Jin;Kang Gyu-Hong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.129-136
    • /
    • 2005
  • This paper presents a design strategy of SPOKE type BLDC motors considering an irreversible demagnetization of a permanent magnet (PM). So the irreversible demagnetization characteristic of the motor is analyzed by rotor structure. The instantaneous currents in either starting or lock rotor condition, which are calculated from the current dynamic analysis, are applied to the analysis of the irreversible demagnetization field by FEM. In irreversible demagnetization analysis by FEM, the variation of residual flux density in PM is analyzed using the non-linearity of magnetic core on B-H plan. The analysis results are compared to several rotor structures and used for optimize the rotor structure.

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters (단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석)

  • 강규홍;홍정표
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

A Study on the Variation of Residential Architectural Space Designed by Richard Meier (리차드 마이어의 주거 건축에 나타난 공간 설계 변화 연구)

  • Lee, Sun-Min;Joh, Eun-Ran;Hur, Bum-Pall
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.2
    • /
    • pp.131-138
    • /
    • 2011
  • This study describes development process of residential architectural space in the Richard Meier's residential works through chronological analysis. By analyzing house layout, floor plan, elevation, materials and colors and light entering of his residential works, changes in his architectural space has been studied. Richard Meier's early work is designed as three-dimensional shape, and places emphasis on geometric form. However, recently completed residential works by Richard Meier focuses on the horizontal sun shading louvers, which has ability. In addition, teak and a special UV protective glass are used to control natural environment. Through this research, it was found that Richard Meier has maintained his architectural language in terms of the design layout of the house and planar with colors that appear on the initial project. Using light input methods and materials used for active development, it was found that many design elements were applied and developed.

A Study on the method for finding the degree of proficiency of technicians by the use of VTR and Machine of working character tests by a pattern of YK (VTR 및 YK식(式) 작업성격검사기(作業性格檢査器)를 이용(利用)한 기능공(技能工)의 숙련도측정(熟練度測定)에 관(關)한 연구(硏究))

  • Lee, Sun-Yo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.2 no.1
    • /
    • pp.45-60
    • /
    • 1976
  • In this study, Multiple Factor Analysis was undertaken for the purpose of substituting General Vocational Aptitude tester for paper tests according to the standardized and partially modified norm, and compared and analyzed these aptitude tests YK Type Working Character test for a test battery. In this analysis, four basis aptitude cluster of AQE was utilized as aptitude cluster, the study for skill was carried out by the method of sampling electronic aptitude cluster in four basis ones, and the parts needed in the process of its analysis were investigated by means of Video-Tape Recording. This paper was performed with sample test by application of the inverse variation curve from learning theory and induced learning rate as a measure of the degree of proficient of technicians, and from the obtained results illustrated optimum newly-production plan of ability program and load program by the use of computer program.

  • PDF