• Title/Summary/Keyword: Plan Unit

Search Result 1,096, Processing Time 0.034 seconds

An Analysis of Change on the Apartment Unit Plans and the Interior Spaces Related to Women (여성관련 공간을 중심으로 본 서울지역 아파트의 공간구조 변화)

  • Choi, Byung-Sook;Park, Jung-A
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.39-47
    • /
    • 2009
  • The purpose of this study is to find out the changes on the metropolitan condominium apartment unit plans based on the interior spaces related to women such An-bang (master bedroom), bathroom and attached spaces to the master bedroom, living room, diningroom, kitchen, utility room, and balcony. This study used the content analysis method and space syntax. Contents were limited to the floor plans with 3 rooms type and about 105 m2 in the Korean apartment encyclopedia. The unit plans of 2,278, built from October 1975 to January 2008, were analyzed and basically SPSS package 16.0 was employed. The results were as followed. 1) Living room was a core space and an increasing tendency. After 2001, the design trend of living room connected with kitchen and dining room, and dining room changed into one space combining with women's working space such kitchen. It meaned women's working activities became into family public activities as to depending open access. 2) Kitchen had a characteristics that was connected to utility room or back balcony, and the number of extra kitchen increased. Also, the size of DK decreased, but utility size little increased. It was showed the characteristic of this space was still for women. 3) An-bang had a little strong characteristics of married coulpe or women's personal space with bathroom or dress room/powder room. 4) In addition, the values of integration and control of living room and DK were highest. It meant these space were centered in unit plans. Next, the An-bang and dress room/powder room were high. Utility room or balcony's were next, and these were women's working space. Therefore, family's public space was most important, and married couple or women's personal and working space were later in planning.

Research on the relationship of store unit configuration and business activation of street mall - Based on case studies of street malls in Korea - (스트릿 몰(Street Mall)의 매장 배분계획과 영업활성화의 관계에 대한 연구 - 국내 스트릿 몰의 사례를 중심으로 -)

  • Woo, Seung-Hyun;Yoon, Hea-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.202-210
    • /
    • 2009
  • This research was undertaken to prove the relationship between street mall activation and architectural plan design. The research methodology was established based on the analysis of data of two existing street malls in Korea (Western Dome & LaFesta) and theoretical studies of outdoor space design. The findings from this study are the following: First, building blocks with segments in every 50m or so are ideal for detailed communication between visitors and building contents. Second, the ratio of width of main corridor and building height should be less than 1 to provide intimate feel and keep visitors' attention concentrated in the facility. Third, store unit should have more storefronts to be exposed more to passers-by and lead more pedestrian traffic. Fourth, shape of store unit would rather be wide and shallow, instead of narrow and deep, to have more exposure to the central corridor. Fifth, the building block of the busiest(most expensive) area that is usually at the main entrance area of street mall should be flexible to fit more smaller units to maximize the profitability. Sixth, the main entrance of store should face the main pedestrian corridor to induce the influx of visitors. Lastly seventh, anchor tenant that has strong name recognition is usually located on basement or higher level to induce pedestrian traffic into the mall, key tenants that are strong and familiar brand names should be located at the corner of building block with spacing to attract visitors, provide even distribution of traffic, and support wayfinding, and local tenant should be located at small units along the central corridor or remainder spaces occurred from building core layout.

A Study on the Structural System of Space Configuration in Architectural Plane - Focusing on the Coalesce scheme development for part-whole Process - (건축 평면에서 공간 형상의 구조 체계에 관한 연구 - 부분이 전체를 이루는 합체 도식 개발을 중심으로 -)

  • Piao, Shun-Mei;Yoon, Chae-Shin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.9-20
    • /
    • 2018
  • There are many large and small spaces in the interior of the building, and these spaces are arranged and connected to form a systematic spatial structure. A structure is a collection of several parts to form a whole. In other words, the spatial structure in architecture can be seen as a whole organized and organized as individual unit spaces are gathered together. Therefore, in order to understand the spatial structure, we first need to define the unit spaces that form part, how they are interconnected and arranged, and then understand how and how these unit spaces are organized to form a whole. The main purpose of this study is to study the structural system of space based on the shape information of space on architectural plane. This means interpreting the process and method of how the unit spaces defined as a certain shape on the architectural plane are organized step by step, integrated into a higher level, and eventually integrated into one whole. In this paper, the shape and layout of the unit space are identified in the architectural plan, the connection relation is defined, and expressed in the network form. And suggests a new methodology for interpreting the organizational process in which the following spaces are integrated as a whole. This new methodology is based on human perceptual characteristics. When people recognize an object, they recognize the object partly and completely. We want to explain the relationship between parts of space and the whole according to their characteristics.

OPTIMIZING QUALITY AND COST OF METAL CURTAIN WALL USING MULTI-OBJECTIVE GENETIC ALGORITHM AND QUALITY FUNCTION DEPLOYMENT

  • Tae-Kyung Lim;Chang-Baek Son;Jae-Jin Son;Dong-Eun Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.409-416
    • /
    • 2009
  • This paper presents a tool called Quality-Cost optimization system (QCOS), which integrates Multi-Objective Genetic Algorithm (MOGA) and Quality Function Deployment (QFD), for tradeoff between quality and cost of the unitized metal curtain-wall unit. A construction owner as the external customer pursues to maximize the quality of the curtain-wall unit. However, the contractor as the internal customer pursues to minimize the cost involved in designing, manufacturing and installing the curtain-wall unit. It is crucial for project manager to find the tradeoff point which satisfies the conflicting interests pursued by the both parties. The system would be beneficial to establish a quality plan satisfying the both parties. Survey questionnaires were administered to the construction owner who has an experience of curtain-wall project, the architects who are the independent assessor, and the contractors who were involved in curtain-wall design and installation. The Customer Requirements (CRs) and their importance weights, the relationship between CRs and Technical Attributes (TAs) consisting of a curtain-wall unit, and the cost ratios of each components consisting curtain-wall unit are obtained from the three groups mentioned previously. The data obtained from the surveys were used as the QFD input to compute the Owner Satisfaction (OS) and Contractor Satisfaction (CS). MOGA is applied to optimize resource allocation under limited budget when multi-objectives, OS and CS, are pursued at the same time. The deterministic multi-objective optimization method using MOGA and QFD is extended to stochastic model to better deal with the uncertainties of QFD input and the variability of QFD output. A case study demonstrates the system and verifies the system conformance.

  • PDF

Development of Methodology for Measuring Water Level in Agricultural Water Reservoir through Deep Learning anlaysis of CCTV Images (딥러닝 기법을 이용한 농업용저수지 CCTV 영상 기반의 수위계측 방법 개발)

  • Joo, Donghyuk;Lee, Sang-Hyun;Choi, Gyu-Hoon;Yoo, Seung-Hwan;Na, Ra;Kim, Hayoung;Oh, Chang-Jo;Yoon, Kwang-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.15-26
    • /
    • 2023
  • This study aimed to evaluate the performance of water level classification from CCTV images in agricultural facilities such as reservoirs. Recently, the CCTV system, widely used for facility monitor or disaster detection, can automatically detect and identify people and objects from the images by developing new technologies such as a deep learning system. Accordingly, we applied the ResNet-50 deep learning system based on Convolutional Neural Network and analyzed the water level of the agricultural reservoir from CCTV images obtained from TOMS (Total Operation Management System) of the Korea Rural Community Corporation. As a result, the accuracy of water level detection was improved by excluding night and rainfall CCTV images and applying measures. For example, the error rate significantly decreased from 24.39 % to 1.43 % in the Bakseok reservoir. We believe that the utilization of CCTVs should be further improved when calculating the amount of water supply and establishing a supply plan according to the integrated water management policy.

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

A Guideline for Construction Management Plan Based on the Characteristics of $CO_2$ Emissions: A Case Study for a High-Rise Residential Building Project ($CO_2$ 배출 특성을 고려한 건설폐기물 관리방안 수립기준: 고층 주거건물 건설 프로젝트를 대상으로 한 사례조사)

  • Kim, Jee-Hye;Shin, Dong-Woo;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.6
    • /
    • pp.150-158
    • /
    • 2007
  • As the amount of $CO_2$ emission in Korea is ranked 9th and the increasing rate of $CO_2$ emissions highest in the world, it is strongly necessary to devise methods to decrease the amount of $CO_2$ in each industry as the basis of establishing environmentally sustainable production system. This paper aims to identify the characteristics of $CO_2$ emissions from construction wastes throughout the simplified LCA (Life Cycle Assessment) and suggest the strategic guideline for the construction waste management plan to decrease $CO_2$. As a result of LCA on the case of a high-rise residential building project, total sum of $CO_2$ emission generated from construction wastes appeared as 6,818,123kg-$CO_2$ and $CO_2$ emission per unit floor area as 21.01kg-$CO_2/{\beta}{\ge}$. The principal waste materials generating more than 95% of $CO_2$ are materials such as reinforcing bar, temporary materials, cement, ready-mixed-concrete, concrete products, and tile, which have relatively high unit emission rate of $CO_2$ in the process of production. Besides, more than 92% of $CO_2$ was generated from the activities such as structure work, plaster work, temporary work, and tile and stone work, which are generally executed in the early phase of the whole construction period. Reflecting these results, the guideline for the construction waste management plan was recommended. If the waste management plan is established considering the guideline suggested, there would be high potential to decrease the amount of $CO_2$ generated from construction wastes.

A Study on the Method for Converting the Unit Database from Training-model into Analysis-model : Focused on the 'Chang-Jo21' and 'Vision21' model (훈련용 워게임 모델의 부대 DB를 분석용 워게임 모델에 재사용하기 위한 변환방법 연구 : 창조21모델과 비전21모델을 중심으로)

  • Lee, Yong-Bok;Park, Min-Hyoung;Kim, Yeek-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.159-167
    • /
    • 2019
  • In the field of defense M&S, we are actively pursuing researches that interoperable multiple war game models to simulate various combat environments at the same time. Although the 'unit DB(Database)' for operating the war game models is originated from the identical data, it has been recognized that the method of expressing the attribute of the data is different and the cross reference is impossible. As a result, it makes unnecessary time and effort in establishing the same unit DB in the organizations that operate the war game model. In this study, a method of reusing the unit DB of the training war game model to the analysis war game model with similar resolution and simulated logic was applied to the actual field. For this purpose, we defined the procedure for converting the unit DB by analyzing metadata of the 'Chang-Jo21', a combat training model for corps and division, and the 'Vision21', an analysis model for corps and division operation plan. And we introduced an algorithm that can map different metadata of two unit DBs. This study was meaningful as the first attempt to map and integrate heterogeneous metadata semantically for the reuse of unit DB between different war game models in defense M&S field. Also, it provided implications for the necessity of paradigm shift that reuse of the unit DB between two different war game models is possible and the need for standardization of the unit DB metadata in the defense M&S filed.

Analysis of the Effect of Heat Island on the Administrative District Unit in Seoul Using LANDSAT Image (LANDSAT영상을 이용한 서울시 행정구역 단위의 열섬효과 분석)

  • Lee, Kyung Il;Ryu, Jieun;Jeon, Seong Woo;Jung, Hui Cheul;Kang, Jin Young
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.821-834
    • /
    • 2017
  • The increase in the rate of industrialization due to urbanization has caused the Urban Heat Island phenomenon where the temperature of the city is higher than the surrounding area, and its intensity is increasing with climate change. Among the cities where heat island phenomenon occurs, Seoul city has different degree of urbanization, green area ratio, energy consumption, and population density in each administrative district, and as a result, the strength of heat island is also different. So It is necessary to analyze the difference of Urban Heat Island Intensity by administrative district and the cause. In this study, the UHI intensity of the administrative gu and the administrative dong were extracted from the Seoul metropolitan area and the differences among the administrative districts were examined. and linear regression analysis were conducted with The variables included in the three categories(weather condition, anthropogenic heat generation, and land use characteristics) to investigate the cause of the difference in heat UHI intensity in each administrative district. As a result of analysis, UHI Intensity was found to be different according to the characteristics of administrative gu, administrative dong, and surrounding environment. The difference in administrative dong was larger than gu unit, and the UHI Intensity of gu and the UHI Intensity distribution of dongs belonging to the gu were also different. Linear regression analysis showed that there was a difference in heat island development intensity according to the average wind speed, development degree, Soil Adjusted Vegetation Index (SAVI), Normalized Difference Built-up Index (NDBI) value. Among them, the SAVI and NDBI showed a difference in value up to the dong unit and The creation of a wind route environment for the mitigation of the heat island phenomenon is necessary for the administrative dong unit level. Therefore, it is considered that projects for mitigating heat island phenomenon such as land cover improvement plan, wind route improvement plan, and green wall surface plan for development area need to consider administrative dongs belonging to the gu rather than just considering the difference of administrative gu units. The results of this study are expected to provide the directions for urban thermal environment design and policy development in the future by deriving the necessity of analysis unit and the factors to be considered for the administrative city unit to mitigate the urban heat island phenomenon.

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.