• Title/Summary/Keyword: Placements

Search Result 152, Processing Time 0.026 seconds

Comparison of Power Loss and Magnetic Flux Distribution in Octagonal Wound Transformer Core Configurations

  • Cinar, Mehmet Aytac;Alboyaci, Bora;Sengul, Mehlika
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1290-1295
    • /
    • 2014
  • In this paper, various configurations of octagonal wound transformer core topology, which has previously proved advantages on conventional wound cores, are studied. Each configuration has different joint types and different placement of joint zones on the core. Magnetic flux distributions and power losses of each configuration are analyzed and compared. Comparisons are based on both 2D&3D finite element simulations and experimental studies. The results show that, joint types and their placements on the core cause local flux accumulations and dramatically affect power loss of the core.

A Comprehensive Survey of Optimal Placement and Coordinated Control Techniques of FACTS Controllers in Multi-Machine Power System Environments

  • Singh, Bindeshwar;Sharma, N.K.;Tiwari, A.N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.79-102
    • /
    • 2010
  • This paper presents exhaustive review of various methods/techniques for coordinated control between FACTS controllers in multi-machine power systems. It also reviews various techniques/methods for optimal choice and allocation of FACTS controllers. Authors strongly believe that this survey article will be very much useful to the researchers for finding out the relevant references in the field of placement and coordination of FACTS Controllers.

An efficient Methods for Placing the Cooling Lines and Ejector Pins of Injection Mold in 3D CAD system (3D CAD를 이용한 사출금형의 쿨링 라인과 이젝터 핀의 효과적인 배치 방법)

  • Lee, Cheol-Soo;Park, Gwang-Ryeol
    • IE interfaces
    • /
    • v.13 no.2
    • /
    • pp.157-165
    • /
    • 2000
  • In this paper, an efficient method is proposed to place the cooling lines(CLS) and ejector pins(EPS) of mold design. The other components of mold, except CLS and EPS, can be generated automatically by batch processing. But the placements and sizes of CLS and EPS depend on the shapes of a part, so that the design works of CLS and EPS should be processed interactively. Using the pre-defined reference points, the positions of CLS and EPS can be determined interactively. By the proposed method, the interference occurred during placing CLS and EPS can be avoided, and the proper lengths of them can be calculated automatically. The information of the positions and lengths are stored in BOM database for generating a machining data. The proposed method is implemented with Unigraphics API functions and C language, tested on Unigraphics V15.

  • PDF

Two New Species and a New Chinese Record of Hypocreaceae as Evidenced by Morphological and Molecular Data

  • Zeng, Zhao Qing;Zhuang, Wen Ying
    • Mycobiology
    • /
    • v.47 no.3
    • /
    • pp.280-291
    • /
    • 2019
  • To explore species diversity of Hypocreaceae, collections from Guangdong, Hubei, and Tibet of China were examined and two new species and a new Chinese record were discovered. Morphological characteristics and DNA sequence analyses of the ITS, LSU, $EF-1{\alpha}$, and RPB2 regions support their placements in Hypocreaceae and the establishments of the new species. Hypomyces hubeiensis sp. nov. is characterized by occurrence on fruitbody of Agaricus sp., concentric rings formed on MEA medium, verticillium-like conidiophores, subulate phialides, rod-shaped to narrowly ellipsoidal conidia, and absence of chlamydospores. Trichoderma subiculoides sp. nov. is distinguished by effuse to confluent rudimentary stromata lacking of a well-developed flank and not changing color in KOH, subcylindrical asci containing eight ascospores that disarticulate into 16 dimorphic part-ascospores, verticillium-like conidiophores, subcylindrical phialides, and subellipsoidal to rod-shaped conidia. Morphological distinctions between the new species and their close relatives are discussed. Hypomyces orthosporus is found for the first time from China.

Arthroscopic Latarjet procedure: current concepts and surgical techniques

  • Sang-Jin Shin;Jae Hyung Kim;Jonghyun Ahn
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.445-454
    • /
    • 2023
  • The Latarjet procedure is a surgical procedure that can effectively restore glenohumeral stability, especially in patients with anterior shoulder instability and glenoid bone loss. Many studies have shown comparable clinical outcomes between patients undergoing the arthroscopic Latarjet procedure and those undergoing traditional open methods or other glenohumeral joint stabilization procedures. However, the arthroscopic Latarjet procedure is a challenging technique due to the unfamiliar portal placements, proximity of neurovascular structures, and serious postoperative complications. The arthroscopic Latarjet procedure has not yet been widely applied, and a clear understanding of the anatomical structure and the precise methods is required prior to operation performance. Satisfactory clinical outcomes can be achieved by thorough preoperative planning and proper implant fixation methods.

Effects of Polyethylene Mulch and Levels and Placements of Nitrogen on Soil Properties and Sweet Corn Growth (비닐 피복, 질소시비량 및 시비방법이 토양의 이화학적 특성과 단옥수수의 생육에 미치는 영향)

  • 이석순;백준호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.3
    • /
    • pp.334-339
    • /
    • 1985
  • A sweet corn hybrid, Honey Bantam, was planted on 24 May, 1984 in a silty clay loam soil to investigate the effects of polyethylene(P.E.) mulch and different levels and placements of Nitrogen(N) on soil properties and sweet corn growth. A split-split plot design with three replications was employed; P.E. mulch and bare soil were main plot, N levele of 8, 12, 16, and 20 kg/10a were subplot, and band and broadcast of fertilizers were sub-subplots. At early growth stage soil temperature under P.E. mulch was higher than that in bare soil by 5-10$^{\circ}C$, but the differences decreased as plant growth advanced. Soil hardness increased with soil depth while P.E. mulch reduced soil hardness probably by holding high soil moisture. Soil pH decreased up to the 6th week after planting and then increased in bare soil, but it contineously decreased up to the 8th weeks under P.E. mulch regardless N levels and placements. Electrical conductivity(EC) of soil increased up to the 6th weeks after planting and then decreased in all treatments except broadcast of fertilizers under P.E. mulch where EC increased contineously. Generally, soil EC under P.E. mulch was higher than that in broadcast. Broadcast of fertilizers did not affect emergence of seedlings in all N levels under P.E. mulch and bare soil, but band of fertilizers at all N levels under P.E. mulch and higher levels of N in bare soil reduced emergence rate significantly. Percent stand was possitively correlated with soil EC and it strongly influenced the number of marketable ears. Plant growth was enhanced and silking date was earlier by 14-19 days under P.E. mulch compared to bare soil probably due to increased soil moisture, reduced soil hardness and higher soil temperature.

  • PDF

INFLUENCE OF TOPICAL IRRIGATION USING THE HA & PURE Ti IMPLANTS ON BONE FORMATION;A STUDY ON THE IRRADIATED RABBIT TIBIA (방사선 조사후 매식한 임프란트와 관주에 따른 골치유에 대한 비교연구)

  • Hong, Sung-Pal;Rhee, Gun-Joo;Cha, Yong-Doo;Oh, Se-Jong;Hyun, Jung-Min;Choi, Dong-Joo;Park, Young-Joo;Park, Jon-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • In this study, the rate of bone formation and the pattern of bone to implant contact surface around HA coated implant and pure Ti implant inserted into the irradiated tibia of rabbit were compared. Sixteen mongrel mature male rabbits were used as experimental animal. Each rabbit received 15 Gy of irradiation. Four weeks after irradiation, two holes were prepared on the tibia of each rabbit for placement of HA coated type and pure Ti type implants. Prior to implant placement, one group received steroid irrigation and the control group was similarly irrigated with normal saline. This was immediately followed by placement of the two different types of implants. Postoperatively, tetracycline was injected intramuscularly for 3 days. For fluorescent labelling, 3 days of intramuscular alizarine red injection was given. 2 weeks before sacrifice, followed by intramuscular calcein green on the last 3 days before specimen collection. Each rabbit was sacrificed on the second, fourth, sixth and eighth week after the implantation. The specimens were observed by the light microscope and the fluorescent microscope. The results were as follows; 1. All implants inserted into the irradiated tibia of rabbit were free from clinical mobility and no signs of bony resorption were noted around the site of implant placement. 2. Under the light microscope, new bone formation proceeded faster around implants that received steroid irrigation compared to the control group irrigated with saline. Bone to implant contact surface was greater in the steroid irrigated group than the saline irrigated group. Therefore, better initial stabilization was observed in the group pretreated with steroid irrigation. 3. Under the light microscope. HA coated implants showed broader bone to implant contact surface than pure Ti implants, and HA coated implants had better bone healing pattern than pure Ti implants. 4. In the steroid pretreated group, acceleration of bone formation was demonstrated by fluorescent microscopy around the 2, 4 weeks group and the 6 weeks HA coated implant group. The difference in the rate of bone formation proved to be statistically significant(P<0.05). Faster bone formation was noted in the saline irrigated group in the 6 weeks pure Ti implants and 8 weeks group. The difference was not statistically significant(P<0.05). 5. For the rabbits that were sacrificed on the second and fourth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. For the rabbits that were sacrificed on the sixth week after the implant placements, the rates of bone formation around pure Ti implants proceeded faster than those around HA coated implants under the fluorescent microscopy. But this result did not show statistical significance (P<0.05) For the rabbits that were sacrificed on the eighth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. This result was statistically significant (P<0.05).

  • PDF

Evaluation of clinical outcomes of implants placed into the maxillary sinus with a perforated sinus membrane: a retrospective study

  • Kim, Gwang-Seok;Lee, Jae-Wang;Chong, Jong-Hyon;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.50.1-50.6
    • /
    • 2016
  • Background: The aim of this study was to evaluate the clinical outcomes of implants that were placed within the maxillary sinus that has a perforated sinus membrane by the lateral window approach. Methods: We examined the medical records of the patients who had implants placed within the maxillary sinus that has a perforated sinus membrane by the lateral approach at the Department of Oral and Maxillofacial Surgery of Chonnam National University Dental Hospital from January 2009 to December 2015. There were 41 patients (male:female = 28:13). The mean age of patients was $57.2{\pm}7.2years$ at the time of operation (range, 20-76 years). The mean follow-up duration was 2.1 years (range, 0.5-5 years) after implant placement. Regarding the method of sinus elevation, only the lateral approach was included in this study. Results: Ninety-nine implants were placed in 41 patients whose sinus membranes were perforated during lateral approach. The perforated sinus membranes were repaired with a resorbable collagen membrane. Simultaneous implant placements with sinus bone grafting were performed in 37 patients, whereas delayed placements were done in four patients. The average residual bone height was $3.4{\pm}2.0mm$ in cases of simultaneous implant placement and $0.6{\pm}0.9mm$ in cases of delayed placement. Maxillary bone graft with implant placement, performed on the patients with a perforated maxillary sinus membrane did not fail, and the cumulative implant survival rate was 100%. Conclusions: In patients with perforations of the sinus mucosa, sinus elevation and implant placement are possible regardless of the location and size of membrane perforation. Repair using resorbable collagen membrane is a predictable and reliable technique.

Comparison of autogenous tooth bone graft and synthetic bone graft materials used for bone resorption around implants after crestal approach sinus lifting: a retrospective study

  • Kim, Young-Kyun;Lee, Junho;Yun, Ji-Young;Yun, Pil-Young;Um, In-Woong
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.216-221
    • /
    • 2014
  • Purpose: This retrospective study compares the amount of bone resorption around implants between an autogenous tooth bone graft (AutoBT) and a synthetic bone graft after a bone-added crestally approached sinus lift with simultaneous implant placements. Methods: In all, 37 patients participated in this study. Seventeen patients were grouped as group I and underwent an AutoBT-added sinus lift using the crestal approach. The remaining 20 patients were grouped as group II and underwent synthetic bone grafting. Both groups received the implant placements simultaneously. Of the 37 participating patients, only 22 patients were included in the final results: Eleven patients of group I and 11 patients of group II. Before the surgery, the distance from the alveolar crest to the sinus floor was measured using panoramic radiography. After the surgery, the distance was measured again from the neck of the implant thread to the most superior border of the added graft materials. Then, the amount of sinus lift was calculated by comparing the two panoramic radiographs. After a year, a panoramic radiograph was taken to calculate the resorption of the bone graft material from the radiograph that was taken after the surgery. The significance of the resorption amount between the two types of graft materials was statistically analyzed. Results: The bone height was increased to an average of 4.89 mm in group I and 6.22 mm in group II. The analysis of panoramic radiographs 1 year after the surgery showed an average bone resorption of 0.76 mm and 0.53 mm, respectively. However, the degree of lifting (P=0.460) and the amount of bone-grafted material resorption (P=0.570) showed no statistically significant difference. Conclusions: Based on this limited study, AutoBT can be considered a good alternative bone graft to a synthetic bone graft in a bone-added sinus lift, when extraction is necessary prior to the surgery.

Spatial Location Modeling for the Efficient Placements of the Super WiFi Facilities Utilizing White Spaces (화이트 스페이스를 활용한 슈퍼 와이파이 시설의 효율적 배치를 위한 공간 입지 모델링)

  • Lee, Gunhak;Kim, Kamyoung
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.2
    • /
    • pp.259-271
    • /
    • 2013
  • This paper addresses the efficient facility placements to adopt a super WiFi network, taking significant considerations as the next generation 'information highway'. Since the super WiFi has a wider geographic coverage by utilizing the white spaces of TV broadcasting which are empty and available frequencies for the wireless communications, it would play an important role in releasing digital divide of the internet access for low populated or mountainous areas. The purpose of this paper is to explore systematic and efficient spatial plans for the super WiFi. For doing this, we applied optimal location covering models to Gurye-gun, Jeonlanamdo. From the application, we presented optimal locations for super WiFi facilities and significant analytical results, such as the tradeoff between the number of facilities and coverage and marginal coverage for establishing super WiFi network. The results of this research would be usefully utilized for decision makers who wish to adopt a super WiFi, to extend wireless networks in a city or build a regional infrastructure of wireless facilities.

  • PDF