• 제목/요약/키워드: Placement distance

검색결과 146건 처리시간 0.024초

Cross Layer Optimal Design with Guaranteed Reliability under Rayleigh block fading channels

  • Chen, Xue;Hu, Yanling;Liu, Anfeng;Chen, Zhigang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권12호
    • /
    • pp.3071-3095
    • /
    • 2013
  • Configuring optimization of wireless sensor networks, which can improve the network performance such as utilization efficiency and network lifetime with minimal energy, has received considerable attention in recent years. In this paper, a cross layer optimal approach is proposed for multi-source linear network and grid network under Rayleigh block-fading channels, which not only achieves an optimal utility but also guarantees the end-to-end reliability. Specifically, in this paper, we first strictly present the optimization method for optimal nodal number $N^*$, nodal placement $d^*$ and nodal transmission structure $p^*$ under constraints of minimum total energy consumption and minimum unit data transmitting energy consumption. Then, based on the facts that nodal energy consumption is higher for those nodes near the sink and those nodes far from the sink may have remaining energy, a cross layer optimal design is proposed to achieve balanced network energy consumption. The design adopts lower reliability requirement and shorter transmission distance for nodes near the sink, and adopts higher reliability requirement and farther transmission distance for nodes far from the sink, the solvability conditions is given as well. In the end, both the theoretical analysis and experimental results for performance evaluation show that the optimal design indeed can improve the network lifetime by 20-50%, network utility by 20% and guarantee desire level of reliability.

차동식 열감지기 설치기준 비교분석에 관한 연구 (Differential temperature fire detector analysis of comparative study based on sensor installation)

  • 황동환;양광모;강경식
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

병상과 간호스테이션의 관계를 기반으로 한 지방의료원 중환자부 배치유형에 관한 연구 (A Study on the Types of Layout in the Intensive Care Unit of Regional Public Hospitals based on the Relationship between the Beds and Nurse Station)

  • 여정;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.37-46
    • /
    • 2019
  • Purpose: The Intensive Care Unit (ICU) is an important inpatient care area where critical patients are treated intensively with advanced medical technology. The level of care of ICU and the modernization of related facilities is an important indicator of health care quality. At the present time, when the Regional public hospitals are frequently expanding, the rational planning of the ICU has become an important part of the medical institutions treating the ICU. The purpose of this study is to present basic data with net area which can be used in the architectural planning of the ICU. Methods: The investigation and analysis of the ICUs were conducted on 24 medical facilities, based on theoretical analysis through relevant guidelines, articles, and documents, and on the basis of the actual space composition and net area analysis through the architectural drawings. Results: This study provides basic data such as bed placement type of ICU, relationship with other departments, distance between NS and bed, distance between beds, and net area of disease by type. Implications: The results of this paper are expected to be effective reference materials for future research for rational spatial organization and efficient operation of the Intensive Care Unit in regional public hospitals.

A Study on the Supply Process of Unit Modular Housing through a Comparison of Cases

  • Kim, Kyoon-Tai;Jun, Young-Hun;Kim, Tae-Yeong
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.411-414
    • /
    • 2015
  • The purpose of this study is to conduct a comparative analysis between Korea and the United States of the supply process of unit modular housing at both the factory production phase and the transportation and lifting phase, as part of an attempt to invigorate the unit modular housing market in Korea. Unlike the practice in the United States, one of Korea's unique characteristics is that the floor is constructed with reinforced concrete and hot water heating system. To do this, the wet method in Korea is used that includes concrete placement, curing and constructing hot water floor heating system at the factory production phase, which results in a longer production time and also requires the lifting of heavier loads. In the United States, interior and exterior finishing works of modular housing are performed by different companies, and the distance between the unit module factory and the construction site is quite far. This kind of dualized production structure may cause confusion when it comes to schedule management, procurement management, and stock management. Moreover, problems caused by external environmental factors such as wind and rainfall were reported in the course of long-distance transportation. The results of this case comparison are expected to provide fundamental data that will reduce the amount of trial and error in the unit module production, transportation and lifting work in Korea, which has a comparatively small number of unit modular housing cases.

  • PDF

3차원파동장에 있어서 복수열불투과성잠제에 의한 파랑제어에 관한 연구 (Wave Control by Multi-Rowed Impermeable Submerged Breakwaters in Three-Dimensional Wave Fields)

  • 김도삼;배은훈;이봉재
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.107-113
    • /
    • 2001
  • This study is focused on the wave control by economical multi-rowed impermeable submerged breakwaters which need less materials than a one-rowed submerged breakwater. A boundary element method and eigenfunction expansion method based on the Green\`s theorem are appled to analyze the characteristics of wave transformation. Submerged breakwaters are consisted of one and two-row with rectangular section. Wave transformation characteristics are investigated by the various combinations of placement distance and crown water depth.

  • PDF

한국환자에 매식된 ITI 임플란트에 관한 조사 (An analysis of ITI implants placed in korean patients)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.361-370
    • /
    • 2002
  • The aim of this study was to analyze various data of 120 non-submerged ITI implants placed in 64 korean adults. The data were retrieved from patients' charts and registered in the computer and coded for a statistical analysis. The results revealed that the most common type of edentulism was a distal extension case, and the largest number of implants were placed in the mandibular first molar position. Implants were placed more frequently in mandibular, posterior position than maxillary, anterior position, respectively. With respect to the implant diameter and length, an implant with 4.1mm in diameter and more than 10mm in length was the most common. Since a molar position was the most prevalent position for implant placement in korean patients, clinicians should be careful about implant diameter which can resist a strong occlusal force expected in the molar position. In addition, the distance to the mandibular canal and the floor of maxillary sinus should be considered to avoid possible damages, such as nerve injury and sinus perforation in selecting a proper implant length.

이동로봇의 장애물 회피기술 (A Technology of Obstacle Avoidance of Mobile Robot)

  • 오세봉;한성현
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.132-145
    • /
    • 2008
  • We propose a new technique for autonomous navigation and travelling of mobile robot based on ultrasonic sensors through the narrow labyrinth that leave only distance of a few centimeters on each side between the guides and the robot. In our current implementation the ultrasonic sensor system fires at a rate of 100 ms, that is, each of the 8 sensors fires once during each 100 ms interval. This is a very good firing rate, implemented here for optimal performance. This paper presents an extensively tested and verified solution to the problem of obstacle avoidance. Our solution is based on the optimal placement of ultrasonic sensors at strategic locations around the robot. Both the sensor location and the associated navigation algorithm are defined in such a way that only the accurate radial sonar data is used for accurate travelling.

Optimum Logical Topology for WDM Networks

  • Nittayawan, Jittima;Runggeratigul, Suwan
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1371-1374
    • /
    • 2002
  • This paper compares four network con-figurations for using as the logical topology in multi- hop wavelength division multiplexing (WDM) networks. The regular network configurations studied in this paper axe ShuffleNet, de Bruijn graph, hypercube, and Man-hattan street network. Instead of using the weight mean hop distance of node placement problem for comparing optimum logical topology, we introduce a new objective function that includes h and the network cost. It can be seen that the network cost strongly depends on the logical topology selected for the implementation of the network. The objective of this paper is to find an optimum logical topology for WDM networks that gives low as well as low network cost.

  • PDF

나르시스현상 감소를 위한 적외선용 굴절식 시준기 설계 (Design of Infrared Refractive Collimator for Reduce Narcissi Effect)

  • 박상우;김종진;원제학;윤석재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.712-715
    • /
    • 2011
  • 원거리의 적외선 영상을 좁은 실험실에서 모의해야할 때 근거리의 적외선 영상이 원거리에 있는 것과 같은 효과를 내기 위하여 적외선용 굴절식 시준기를 사용한다. 이 경우에 적외선이 시준기 렌즈 면에서의 반사, 불규칙적인 굴절 등의 문제로 인해 적외선영상의 중심부 또는 외각부가 흐려지거나 검게 보이는 나르시스현상이 발생한다. 이러한 문제를 해결하기위한 적외선 시준기 렌즈의 굴절률 및 배치 최적화와 렌즈표면의 코팅처리를 통하여 나르시스현상을 최소화할 수 있는 방안에 대하여 논하고자 한다.

  • PDF

3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean

  • Jeon, Yong Hyun;Lee, Chul Kwon;Kim, Hee-Jung;Chung, Jae-Heon;Kim, Heung-Joong;Yu, Sun-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.470-475
    • /
    • 2017
  • PURPOSE. The purpose of this study was to identify the complex course of the mandibular canal using 3D reconstruction of microCT images and to provide the diagram for clinicians to help them understand at the interforaminal region in Korean. MATERIALS AND METHODS. Twenty-six hemimandibles obtained from cadavers were examined using microCT, and the images were reconstructed. At both the midpoint of mental foramen and the tip of anterior loop, the bucco-lingual position, the height from the mandibular inferior border, the horizontal distance between two points, and position relative to tooth site on the mandibular canal were measured. The angle that the mental canal diverges from the mandibular canal was measured in posterior-superior and lateral-superior direction. RESULTS. The buccal distance from the mandibular canal was significantly much shorter than lingual distance at both the mental foramen and the tip of anterior loop. The mandibular canal at the tip of anterior loop was significantly located closer to buccal side and higher than at the mental foramen. And the mental canal most commonly diverged from the mandibular canal below the first premolar by approximately $50^{\circ}$ posterior-superior and $41^{\circ}$ lateral-superior direction, which had with a mean length of 5.19 mm in front of the mental foramen, and exited to the mental foramen below the second premolar. CONCLUSION. These results suggest that it could form a hazardous tetrahedron space at the interforaminal region, thus, the clinician need to pay attention to the width of a premolar tooth from the mental foramen during dental implant placement.