• 제목/요약/키워드: Placement Height

Search Result 169, Processing Time 0.03 seconds

Evaluation of accuracies of genomic predictions for body conformation traits in Korean Holstein

  • Md Azizul Haque;Mohammad Zahangir Alam;Asif Iqbal;Yun Mi Lee;Chang Gwon Dang;Jong Joo Kim
    • Animal Bioscience
    • /
    • v.37 no.4
    • /
    • pp.555-566
    • /
    • 2024
  • Objective: This study aimed to assess the genetic parameters and accuracy of genomic predictions for twenty-four linear body conformation traits and overall conformation scores in Korean Holstein dairy cows. Methods: A dataset of 2,206 Korean Holsteins was collected, and genotyping was performed using the Illumina Bovine 50K single nucleotide polymorphism (SNP) chip. The traits investigated included body traits (stature, height at front end, chest width, body depth, angularity, body condition score, and locomotion), rump traits (rump angle, rump width, and loin strength), feet and leg traits (rear leg set, rear leg rear view, foot angle, heel depth, and bone quality), udder traits (udder depth, udder texture, udder support, fore udder attachment, front teat placement, front teat length, rear udder height, rear udder width, and rear teat placement), and overall conformation score. Accuracy of genomic predictions was assessed using the single-trait animal model genomic best linear unbiased prediction method implemented in the ASReml-SA v4.2 software. Results: Heritability estimates ranged from 0.10 to 0.50 for body traits, 0.21 to 0.35 for rump traits, 0.13 to 0.29 for feet and leg traits, and 0.05 to 0.46 for udder traits. Rump traits exhibited the highest average heritability (0.29), while feet and leg traits had the lowest estimates (0.21). Accuracy of genomic predictions varied among the twenty-four linear body conformation traits, ranging from 0.26 to 0.49. The heritability and prediction accuracy of genomic estimated breeding value (GEBV) for the overall conformation score were 0.45 and 0.46, respectively. The GEBVs for body conformation traits in Korean Holstein cows had low accuracy, falling below the 50% threshold. Conclusion: The limited response to selection for body conformation traits in Korean Holsteins may be attributed to both the low heritability of these traits and the lower accuracy estimates for GEBVs. Further research is needed to enhance the accuracy of GEBVs and improve the selection response for these traits.

A Study on the Chimi Excavated from the Middle Gate Remains of Bunhwangsa Temple (분황사 중문지 출토 치미 연구)

  • Kim, Sookyung
    • Journal of architectural history
    • /
    • v.26 no.5
    • /
    • pp.19-26
    • /
    • 2017
  • This paper aimed to identify the architectural characteristics of the chimi excavated from ancient ruins, especially middle gate remains of Bunhwangsa Temple in the Unified Silla period. Middle gate had planned $3{\times}2$ with 295mm measuring unit and gabled building. Detailed study of the shape of chimi of the middle gate restored by related field experts reveals as follows. 1) Height of chimi is 4.5(130.6cm) of Tang's system of measurement classified as large one. 2) The front and back side square hole is made for transverse timber placement. 3) Position of chimi is not the end of the ridge of roof, it moved toward the center. 4) Construction method of chimi is structured with smaller beam and center column. 5) Width and height of the ridge is less than 38cm and 54cm to be approximately, Width and height of the gabled ridge is less than 38cm and 50cm. 6) This chimi is considered to be very unique when compared to existing ancient restored chimis, it is designed to be advantageous to the chimi construction.

A radiographic evaluation of graft height changes after maxillary sinus augmentation and placement of dental implants (상악동 골이식술을 동반한 임플란트 식립 시 골이식재의 높이 변화에 대한 방사선학적 평가)

  • Kim, Ji-Sun;Lee, Seo-Kyoung;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kyu;Kim, Chong-Kwan;Pang, Eun-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.277-286
    • /
    • 2007
  • The edentulous posterior maxilla generally provides a limited amount of bone height because of atrophy of the ridge and pneumatization of the maxillary sinus, Maxillary sinus augmentation is one of the surgical techniques for reconstruction of the severely resorbed posterior maxilla. The purpose of this study was to evaluate the survival rate of implants and the long-term changes of graft height after maxillary sinus augmentation by lateral window approach. From September 1996 to July 2004, maxillary sinus augmentation with mixed grafts of autograft, allograft, xenograft and alloplast were performed on 45 patients and 100 implants were placed. We evaluated the survival rate of implants and the changes of BL(bone length)/IL(implant length) according to time using panoramic radiographs. The survival rate of implants was 91.0% for follow-up period. The mean reduction of graft heights was 0.34mm(3.0%) for 6 months and 1.22mm(1O.66%) for 3 years after augmentation. The total mean BL/IL was $1.34{\pm}0.21$ during 5 year observation period after augmentation and decreased slightly over time. The result means that graft materials were stable above the implant apex. BL/ILs of 1stage procedure were significantly decreased at 1-2 year, 3-4 year after augmentation and no statistically significant changes were observed in those of 2 stage procedure. The graft materials of both procedures were stable above the implant apex. No statistically significant changes of BL/IL were observed in the grafts combined with low amount of autogenous bone or without autogenous bone. The graft materials of both groups were stable above the implant apex. The results indicated that the placement of dental implants with maxillary sinus augmentation showed predictable clinical results and the grafts combined with low amount of autogenous bone or without autogenous bone had long-term resistance to resorption in maxillary sinus.

A Study on the Strength Estimation of Concrete Using Microwave (마이크로파를 이용한 콘크리트 강도추정에 관한 연구)

  • 박일용;이종균;박영진;안형준;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.219-222
    • /
    • 1999
  • Concrete is to be important quality in placement point and exact test method needed about early judgement method concrete on placement point. But early judgement method of concrete proposed various kind of method because the problems of accuracy and the time required of test exists, it is used within the limits. This study is to propose of early strength judgement by using microwave for accurate estimating early strength of concrete and to develop test machine. Through out this study we find that belows. 1) Strength development of concrete specimen according to the time heated by microwave showed the height strength development in 9 minutes regardless of slump and w/c. 2) As cooling time is long, strength of concrete specimen according to the time heated by microwave showed high strength development and this tendency is like regardless of heating time, w/c and slump. 3) As w/c is high, accelerating strength development according to w/c showed lower strength development and this tendency is like regardless of slump, heating time and cooling time. 4) As slump is big, compressive strength of specimen in standard curing showed lower value and as w/c is big, strength development showed lower

  • PDF

A CLINICAL STUDY OF MAXILLARY SINUS GRAFT FOR IMPLANT PLACEMENT (임프란트 식립시 상악동점막거상술후 예후에 관한 임상적 연구)

  • Park, Lae-yeun;Lee, Jong-han;Kim, O-hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.166-172
    • /
    • 1998
  • Missing of the upper posterior dentition can cause alveolar bone resorption & pneumatization of Maxillary sinus wall, which makes traditional implant placement impossible, The solution includes various methods to the posterior maxilla to provide adequate bone support for implant installation and long-term survival. -- sinus floor elevation, sinus-lift graft, inlay graft using LeFort I osteotomy, onlay graft, This is a clinical Sr. retrospective study on implant surgery & prosthodontic restoration with upper edentulous posterior jaw from Jan. 1990. to Jun. 1997 at implant clinic of Chonbuk National University Hospital. The results obtained were as follows: 1. Six hundred ninety-nine implants were placed on upper posterior jaw of two hundred seventeen patients, among them one hundred sixty-five implants were placed in forty-four patients with sinus lift. 2. The height of the remained alveolar bone was classified on the base of Misch's concept. This included seventy-nine SA-1s, ninety-seven SA-2s, sixty-five SA-3s and sixty SA-4s. 3. Ninety percent of implants were successfully integrated in non-grafted area and eighty-seven percent of implants were successully integrated in sinus lift area.

  • PDF

Phenotypic Factor Analysis for Linear Type Traits in Beijing Holstein Cows

  • Chu, M.X.;Shi, S.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.11
    • /
    • pp.1527-1530
    • /
    • 2002
  • Factor analysis was applied to the phenotypic correlation matrix of 15 linear type traits (scored linearly 1 to 50 points) for 2035 Holstein cows of 38 sires computed from data collected between 1988 and 1992 in Beijing Shuangqiao Farm and Beijing Xijiao Farm. The 15 linear type traits were stature, body strength, body depth, dairy form, rump angle, rump length, rump width, rear leg side view, foot angle, fore udder attachment, rear udder height, rear udder width, udder cleft, udder depth and teat placement rear view. The first four components accounted for 49.1% of the total variance in type scores. Factor 1 reflected strong cows, with deep bodies, with long and wide rumps, and tall in stature. Factor 2 reflected cows with well attached fore udders, wide rear udders and whose udders were supported by strong suspensory ligaments with close teat placement. Factor 3 reflected cows with good dairyness, sickled in the hocks, high rear udders and udder floors above the hocks. Factor 4 reflected cows with sloping rumps from hooks to pins and with steep foot angle. Principal component and factor analyses are useful to clarify the relationships among type traits.

IMPLANT REHABILITATION IN THE UNFAVORABLE ALVEOLAR RIDGE (불량한 치조제에서의 임플랜트 시술증례)

  • Park, Jae-Bum;Ahn, Sang-Hun;Cheung, Soo-Il;Jo, Byung-Woan;Ahn, Jae-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.1
    • /
    • pp.35-44
    • /
    • 1997
  • The most critical factor in determining which type of implant to be used would be the available bone of the patient. Usually a minimum of 5mm in the bone width and 8mm in the bone height is necessary to ensure primary implant stability and maintain the integrity of bone contact surface. Placement of implant is limited by the several anatomic strutures such as maxillary sinus, floor of the nose, inferior alveolar neurovascular bundle and nasopalatine foramen, etc. When severe resorption of alveolar ridge is encountered, implant placement would be a problematic procedure. A number of techniques to improve the poor anatomic situations have been proposed. This article reports 4 cases of patients using surgical procedures such as blade implant technique, cortical split technique in the anterior maxillary area, sinus lifting and lateral repositioning of inferior alveolar nerve, We treated dental implant candidates with unfavorable alveolar ridge utilizing various surgical techniques, resulted in successful rehabilitation of edentulous ridge.

  • PDF

RESONANCE FREQUENCY ANALYSIS IN NON-SUBMERGED, INTERNAL TYPE IMPLANT WITH SINUS AUGMENTATION USING DEPROTEINIZED BOVINE BONE MINERAL (이종골을 이용한 상악동 측벽거상술과 동시 식립한 임프란트에서 안정성에 대한 공진 주파수 분석)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Lee, Jin-Sook;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.554-560
    • /
    • 2008
  • In posterior maxilla, it is difficult to achieve primary stability of implants due to sinus pneumatization, alveolar bone loss, and low bone quality. The accurate and objective primary stability assessment is important for good prognosis of implants. Purpose: The aim of this study was to assess the primary stability of the non-submerged, internal type implants with maxillary sinus augmentation using deproteinized bovine bone mineral by a resonance frequency analyzer, when residual alveolar bone height is under 8mm Materials and methods: A total of 20 implants was placed into 5 grafted maxillary sinuses in 5 patients. Deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was used as graft material. SS II implants (diameter 4.1mm, and length 11.5mm, SLA suface)) were placed. All of the patients received maxillary sinus graft procedure by 1-step technique. Residual bone height was $1.3{\sim}7.8mm$ (mean 4.4mm) measured by panorama radiography. After implant placement, RFA was measured at 4,8,12,20 weeks. The results were divided into 2 groups; RFA value under 4mm and over 5mm of bone height. It was statistically analyzed. Results: 1. The primary stability of implants was increased with time 2. The RFA value was above 65 ISQ at 12 weeks 3. There was no correlation between RFA and residual alveolar bone height in maxillary sinus augmentation by 1-step technique. Conclusion: 1-step surgical procedure is a feasible option for patients with as little as 4mm residual alveolar bone height, when utilizing non-submerged, internal type implants with xenografts.

CLINICAL USAGES OF RAMAL AUTOGENOUS BONE GRAFTS IN DENTAL IMPLANT SURGERY (임플란트 식립 수술시 하악지 자가골이식술의 임상적 활용)

  • Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.266-275
    • /
    • 2008
  • Dental endosseous implants require sufficient alveolar bone volume and quality for complete bone coverage and initial stability. But, atrophy or resorption of alveolar bone height and width according to patient's age and period of tooth loss can prevent ideal implant placement. Bone graft procedure has been proposed before or simultaneously with the placement of dental implants in patients with insufficient alveolar bone volume. While allografts, xenografts, and alloplastic bone grafts have been proposed and studied for alveolar ridge augmentation, the use of autogenous bone grafts represents the 'gold standard' for bone augmentation procedures. Conventional bone grafts are usually harvested from distant sites such as the ilium or ribs. Recently there is a growing use of intraoral bone grafts from intraoral donor sites such as mandibular symphysis, mandibular ramus and maxillary tuberosity. We recommend that the mandibular ramus is a safe autogenous bone graft donor site for bone harvesting with low morbidity. We report various effective autogenous bone graft procedures from mandibular ramus for the implant placement on various atrophic alveolar ridges.

Benefits of mineralized bone cortical allograft for immediate implant placement in extraction sites: an in vivo study in dogs

  • Orti, Valerie;Bousquet, Philippe;Tramini, Paul;Gaitan, Cesar;Mertens, Brenda;Cuisinier, Frederic
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.291-302
    • /
    • 2016
  • Purpose: The aim of the present study was to evaluate the effectiveness of using a mineralized bone cortical allograft (MBCA), with or without a resorbable collagenous membrane derived from bovine pericardium, on alveolar bone remodeling after immediate implant placement in a dog model. Methods: Six mongrel dogs were included. The test and control sites were randomly selected. Four biradicular premolars were extracted from the mandible. In control sites, implants without an allograft or membrane were placed immediately in the fresh extraction sockets. In the test sites, an MBCA was placed to fill the gap between the bone socket wall and implant, with or without a resorbable collagenous membrane. Specimens were collected after 1 and 3 months. The amount of residual particles and new bone quality were evaluated by histomorphometry. Results: Few residual graft particles were observed to be closely embedded in the new bone without any contact with the implant surface. The allograft combined with a resorbable collagen membrane limited the resorption of the buccal wall in height and width. The histological quality of the new bone was equivalent to that of the original bone. The MBCA improved the quality of new bone formation, with few residual particles observed at 3 months. Conclusions: The preliminary results of this animal study indicate a real benefit in obtaining new bone as well as in enhancing osseointegration due to the high resorbability of cortical allograft particles, in comparison to the results of xenografts or other biomaterials (mineralized or demineralized cancellous allografts) that have been presented in the literature. Furthermore, the use of an MBCA combined with a collagen membrane in extraction and immediate implant placement limited the extent of post-extraction resorption.