• 제목/요약/키워드: Place Pressure

검색결과 440건 처리시간 0.023초

말뚝형태 및 길이변화를 고려한 수평재하말뚝의 거동특성 (Behavior of Lateral Loaded Piles with Pile shape and Length)

  • 황성욱;김민기;경두현;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1125-1131
    • /
    • 2008
  • In this study, Calibration Chamber Tests for cast-in-place piles in sand were performed for measuring behavior properties of piles. These tests were examined effects of various parameters of soil conditions including the relative density($D_R$), the coefficient of earth pressure, and investigated differences between cylindrical pile and taper-shaped pile with the same volumes. The important effect factors of foundation behavior were investigated by considering embedded depth of piles and shapes of piles, and inspected details of lateral behavior of piles. These results were verified reliabilities of each methods for comparing the results estimated with tests and the results by proposed estimating solutions in the past.

  • PDF

Study on critical buckling load calculation method of piles considering passive and active earth pressure

  • Chen, Yong-Hui;Chen, Long;Xu, Kai;Liu, Lin;Ng, Charles W.W.
    • Structural Engineering and Mechanics
    • /
    • 제48권3호
    • /
    • pp.367-382
    • /
    • 2013
  • Different types of long slender pile shall buckle with weak soil and liquefied stratum surrounded. Different from considering single side earth pressure, it was suggested that the lateral earth pressure can be divided into two categories while buckling: the earth pressure that prevent and promotes the lateral movement. Active and passive earth pressure calculation model was proposed supposing earth pressure changed linearly with displacement considering overlying load, shaft resistance, earth pressure at both sides of the pile. Critical buckling load calculation method was proposed based on the principle of minimum potential energy quoting the earth pressure calculation model. The calculation result was contrasted with the field test result of small diameter TC pile (Plastic Tube Cast-in-place pile). The fix form could be fixed-hinged in the actual calculation assuring the accuracy and certain safety factor. The contributions of pile fix form depend on the pile length for the same geological conditions. There exists critical friction value in specific geological conditions that the side friction has larger impact on the critical buckling load while it is less than the value and has less impact with larger value. The buckling load was not simply changed linearly with friction. The buckling load decreases with increased limit active displacement and the load tend to be constant with larger active displacement value; the critical buckling load will be the same for different fix form for the small values.

Laboratory Experiments for the Force and Load with Pseudo-Dynamic Test: Ex-vivo Study for the Manual Therapy

  • Choi, Wansuk;Choi, Taeseok;Heo, Seoyoon;Lee, Wooram
    • 국제물리치료학회지
    • /
    • 제10권4호
    • /
    • pp.1889-1896
    • /
    • 2019
  • Background: Because of the lack of accurate values for applied forces in manual therapy, manual therapists relies on the magnitude of the individual's perception during applying the force. However, excessive loading maneuvers carry risks for patients. Objective: To establish the relationship between the maximal force applied to swine skin with the specific region, sex, and baseline parameters of the subject. Design: Ex-vivo Study and laboratory Experimental research Methods: 3.5 kg of Korean pork sirloin that is a piece of swine was handled and it was set 3 dimensions; #A; #B; #C. Forty-seven participants who has no experience in physical therapy randomly carried out the experiment, indicated to push each place of the pressure spots with same posture and process under supervision from the instructor who has over 15 years of manual therapy, and we measured the pressure force in each time. Results: The biggest pressure force was recorded in spot #A, and #B was represented after #C. Pressure on #A showed certain statistic relation with height (r=.317, p<.05) and weight (r=.434, p<.01); pressure on #B showed certain relation which has statistical meaning with only height (r=.401, p<.01); pressure on #C emerged to have statistic relationship with height (r=.308, p<.05)and weight (r=.428, p<.01). The age aspect revealed relation with pressure on #A, #B and #C, but that was not statistically significant. Conclusions: It can be inferred that there is the most loss of pressure in the area where cartilage is like an island in the middle.

하퇴 절단 환자의 족부 종류에 따른 심폐 기능의 비교 (A Comparison of Cardio-Pulmanary Function by the use of a Single Axis Foot and SACH Foot in Below-Knee Amputation)

  • 안왕훈;김영희
    • 대한물리치료과학회지
    • /
    • 제7권1호
    • /
    • pp.311-319
    • /
    • 2000
  • This study was to measure whether single axis foot or the SACH foot applied to below-knee amputation patients would bring positive changes to the patients' cardiopulmonary function, and help them to overcome their disability. The experiment took place at Asan Medical Center, University of Ulsan, from July 20th to November 20th, 1999 with 10 below-knee amputation patients. The patients were asked to equip single axis foot and SACH foot by turns and lead them to walk on a treadmill which was designed to increase its steep slope. Patients heart rate and blood pressure were recorded before and after their walking, The heart rate, systolic blood pressure, diastolic blood pressure of the patients who were equipped with, either SACH foot or single axis foot, have been increased with as the slant becoming steeper. The heart rates during the experiment did not show relevant changes according to the kind of foot used and the gradient, but the changes occurred before and after the walking(p=0.0001), The similar result of systolic blood pressure was found during the waking(p=0.01). Below-knee amputation patients are expected to walk and perform the routines better, no matter what type of foot is used, as long as they wear an artificial foot properly and taking features of foot product into consideration

  • PDF

정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정 (Balancing air flow at terminal in CAV duct system with DPM method)

  • 이대우;박명식;박영우
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

초고층공동주택 국소배기용 입상덕트의 배기성능평가에 관한 연구 (Study on the Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;이태규;안정헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.889-894
    • /
    • 2008
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

  • PDF

RELATIONSHIP BETWEEN RADIATION INDUCTED YIELD STRENGTH INCREMENT AND CHARPY TRANSITION TEMPERATURE SHIFT IN REACTOR PRESSURE VESSEL STEELS OF KOREAN NUCLEAR POWER PLANTS

  • Lee, Gyeong-Geun;Lee, Yong-Bok;Kwon, Jun-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.543-550
    • /
    • 2012
  • The decrease in the fracture toughness of ferritic steels in a reactor pressure vessel is an important factor in determining the lifetime of a nuclear power plant. A surveillance program has been in place in Korea since 1979 to assess the structural integrity of RPV steels. In this work, the surveillance data were collected and analyzed statistically in order to derive the empirical relationship between the embrittlement and strengthening of irradiated reactor pressure vessel steels. There was a linear relationship between the yield strength change and the transition temperature shift change at 41 J due to irradiation. The proportional coefficient was about $0.5^{\circ}C$/MPa in the base metals (plate/forgings). The upper shelf energy decrease ratio was non-linearly proportional to the yield strength change, and most of the data lay along the trend curve of the US results. The transition regime temperature interval, ${\Delta}T_T$, was less than the US data. The overall change from irradiation was very similar to the US results. It is expected that the results of this study will be applied to basic research on the multiscale modeling of the irradiation embrittlement of RPV materials in Korea.

연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구 (A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace)

  • 조동현
    • 수산해양교육연구
    • /
    • 제26권6호
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

Passive p-y curves for rigid basement walls supporting granular soils

  • Imad, Elchiti;George, Saad;Shadi S., Najjar
    • Geomechanics and Engineering
    • /
    • 제32권3호
    • /
    • pp.335-346
    • /
    • 2023
  • For structures with underground basement walls, the soil-structure-interaction between the side soil and the walls affects the response of the system. There is interest in quantifying the relationship between the lateral earth pressure and the wall displacement using p-y curves. To date, passive p-y curves in available limited studies were assumed elastic-perfectly plastic. In reality, the relationship between earth pressure and wall displacement is complex. This paper focuses on studying the development of passive p-y curves behind rigid walls supporting granular soils. The study aims at identifying the different components of the passive p-y relationship and proposing a rigorous non-linear p-y model in place of simplified elastic-plastic models. The results of the study show that (1) the p-y relationship that models the stress-displacement response behind a rigid basement wall is highly non-linear, (2) passive p-y curves are affected by the height of the wall, relative density, and depth below the ground surface, and (3) passive p-y curves can be expressed using a truncated hyperbolic model that is defined by a limit state passive pressure that is determined using available logarithmic spiral methods and an initial slope that is expressed using a depth-dependent soil stiffness model.

혈압측정의 정확성 평가 (Evaluating the Accuracy of Blood Pressure Measurement)

  • 조성현;황정해;김은경;오병희;김창엽
    • 한국의료질향상학회지
    • /
    • 제3권1호
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF