• 제목/요약/키워드: Pixel Pitch

검색결과 76건 처리시간 0.033초

몰드와 전자기파에 의한 PDP격벽의 성형에 관한 연구 (A Study on Plasma Display Panel Barrier Rib Fabrication by Mold and Electromagnetic Wave)

  • 손재혁;임용관;정영대;정성일;정해도
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.176-183
    • /
    • 2002
  • Plasma Display Panel(PDP) is a type of flat panel display utilizing the light emission produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalks from adjacent sub-pixels. The mold for forming the barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing processes such as screen printing, sand-blasting and photosensitive glass methods. The mold for PDP barrier ribs have stripes of micro grooves transferring glass-material wall. In this paper , Stripes of grooves of which width 48$\mu$m, depth 124$\mu$m , pitch 274$\mu$m was acquired by machining of single crystal silicon with dicing saw blade. Maximum roughness of the bottom of the grooves was 59.6 nm Ra in grooving Si. Barrier ribs were farmed with silicone rubber mold, which is transferred from grooved Si forming hard mold. Silicone rubber mold has the elasticity, which enable to accommodate the waviness of lower glass plate of PDP. The methods assisted by the microwave and UV was adopted for reducing the forming time of glass paste.

간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

능동형 센서의 깊이 정보를 이용한 컴퓨터 형성 홀로그램 (Computer-generated hologram based on the depth information of active sensor)

  • 김상진;강훈종;유지상;이승현
    • 대한전자공학회논문지SD
    • /
    • 제43권10호
    • /
    • pp.22-27
    • /
    • 2006
  • 본 논문에서는 능동형 센서와 연결된 카메라에서 얻어진 깊이 정보와 칼라 영상으로부터 컴퓨터형성 홀로그램을 제작하는 방법을 제안하였다. CGH 생성을 위해 컴퓨터그래픽 모델을 사용하는 기존의 홀로그래픽 디스플레이 시스템과는 달리, 카메라로 획득되는 각 물체의 칼라 정보 뿐 아니라 깊이 정보를 포함하는 카메라의 실사 영상을 사용하였다. 이 과정은 실사 물체로부터 깊이가 포함된 영상정보를 획득하는 단계와 깊이 정보로부터 추출된 3D 정보를 이용하여 CGH를 생성하는 두 가지 단계로 구성되어 있다. 또한, 홀로그래픽 디스플레이 시스템을 구성하여 제작된 CGH를 디스플레이 하였다. 실험 시스템에서는 1408X1050의 해상도와 10.4um의 픽셀 크기를 갖는 반사형 LCD 패널을 사용하여 CGH로부터 영상을 재생하였다.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

PDP 격벽 성형용 몰드 제작과 성형에 대한 연구 (A Study on Mold Fabrication and Forming for PDP Barrier Ribs)

  • 조인호;정상철;정해도;손재혁
    • 한국정밀공학회지
    • /
    • 제18권5호
    • /
    • pp.171-176
    • /
    • 2001
  • Plasma Display Panel(PDP) is a type of flat panel display utilizing the light emission produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalks from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring glass-material wall. In this paper, Stripes of grooves of which width 48${\mu}{\textrm}{m}$ and 270${\mu}{\textrm}{m}$, depth 124${\mu}{\textrm}{m}$, pitch 274${\mu}{\textrm}{m}$ was acquired by machining hard and brittle materials of WC, Silicon, Alumina with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120nm, 287nm in grooving WC. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of bottom curvatures was 7.75${\mu}{\textrm}{m}$. This results satisfies the specification for barrier ribs of 50 inch XGA PDP if the groove form of mold was fully transferred to the barrier ribs. Barrier ribs were formed with Silicone rubber mold, which is transferred from grooved hard materials. Silicone rubber mold has elasticity accommodating the waveness of lower glass plate of PDP.

  • PDF

Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가 (Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector)

  • 서정호;임현우;박진구;허영;전성채;김봉회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발 (Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks)

  • 장리;염선;신휴성
    • 한국지반공학회논문집
    • /
    • 제36권9호
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray CT는 암석시편의 공극 및 균열과 같은 내부 미세구조와 손상들의 정량적 분석에 활용되어 왔다. 원위치 CT는 외력 등 다양한 외적 요인에 영향을 받고 있는 암석 시편의 내외부 변화 과정을 관찰할 수 있게 해준다. 이의 확인을 위해, 암반/지반재료 특성분석에 활용한 원위치 X-ray CT 기술에 관한 최신 연구동향을 파악하였으며, 원위치 CT이미징이 가능한 암석의 수리-역학적 실험용 삼축셀을 개발하였다. 직경 25~50 mm 화강암 및 사암 코아시편의 원위치 CT이미징이 성공적으로 진행되었으며, 34~105 ㎛ 범위의 픽셀피치의 해상도를 취득할 수 있었다. 본 사전검토 촬영 실험을 통해 마이크로미터 스케일에서 암석의 내부구조 변화의 원위치 CT관찰이 가능한 것을 파악하였다. 요오드화 칼륨 용액은 CT이미지의 대비를 증가시키고 암석의 수리-역학 실험에서 주입유체로 사용할 수 있다.

간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구 (Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

적응적 패럴랙스 베리어를 위한 사용자 위치 추적 방법 (Estimating Location in Real-world of a Observer for Adaptive Parallax Barrier)

  • 강석훈
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1492-1499
    • /
    • 2019
  • 이 논문에서는 적응적 패럴랙스 베리어 방식에서, 시청영역을 제어할 수 있도록 사용자의 위치를 추적하는 방법을 제안한다. 얼굴자세에 강건한 양안거리 측정을 위해, 형태모델과 랜드마크 기반인 CLM으로 자세를 추정한다. 카메라와의 상관관계로, 거리와 수평위치를 거리로 변환한다. 사용자의 눈의 위치에 따라 적응적 패럴랙스 베리어의 화소간격을 조정하고, 베리어를 이동해 시청영역을 조정한다. 이 논문에서는 60cm부터 490cm의 범위에서 사용자를 추적하는 방법을 제안하고, 카메라 영상의 해상도에 따른 에러, 측정 가능 범위, fps를 측정하였다. 그 결과, 사용자를 평균 3.1642cm의 절대오차 범위내로 측정 가능하였으며, 영상의 해상도에 따라 320×240에서 약 278cm, 640×480에서 약 488cm까지, 그리고 1280×960에서 약 493cm까지를 측정할 수 있었다.

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.

  • PDF