• Title/Summary/Keyword: Pitch rate

Search Result 530, Processing Time 0.028 seconds

Acoustic Analysis for Thermal Environment-related Vocalizations in Laying Hens (산란계의 열환경별 특이음에 대한 음성학적 분석)

  • Jeon, J.H.;Yeon, S.C.;Ha, J.K.;Lee, S.J.;Chang, H.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.697-702
    • /
    • 2005
  • The aim of this study was to divide vocalizations of laying hens (Hy-Line Brown) into general vocalizations (GVs), heat stress-related vocalization (HSV), and cold stress-related vocalizations (CSVs) and to determine if they are classified by the discriminant function analysis method. Thirty laying hens, 65-wk-old, were recorded using digital video recorders 2 times from 10:00 to 14:00 h in each thermal environment (thermoneutral: $22.0{\pm}1.8^{\circ}C$, too hot: $32.0{\pm}2.0^{\circ}C$, too cold: $8.0{\pm}1.9^{\circ}C)$ after a 7 day acclimation period. When the laying hens were not recorded, they were kept in thermoneutral conditions. The GVs, HSV, and CSVs were divided based on the shapes of spectrums and spectrograms. The GVs, HSV, and CSVs were identified as 5, 1, and 3 types, respectively. Pitch, intensity, duration, formant 1, formant 2, formant 3, and formant 4 among the thermal environment-related vocalizations were significantly different (P<0.001). The discrimination rate determined by discriminant function analysis was 86.2%. These results suggest that HSV and CSVs are present and may be used as an indicator of the thermal environment.

A Study on Combustion Characteristics in terms of the Type of Fuel Supply Device (Feeder) of a Wood Pellet Boiler (목재펠릿보일러의 연료공급 장치의 형태에 따른 연소특성에 관한 연구)

  • Choi, Yun Sung;Euh, Seung Hee;Oh, Kwang Cheol;Kim, Dae Hyun;Oh, Jae Heun
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • This study reports the combustion characteristics, such as burner temperature and the concentration of exhausted gas ($O_2$, $CO_x$, $NO_x$) due to the different types and pitches of the fuel supply feeder of the wood pellet boiler. The 1st grade wood pellets composed of mainly larch have been used for the experiment. In case of using the spring feeder, mean temperature of burner was approximately $821.76^{\circ}C$, and the mean concentration of oxygen, carbon monoxide, carbon dioxide and nitrogen oxide were approximately 8.88%, 93.35ppm, 12.15% and 139.83 ppm, respectively. The test result with the spring feeder was shown to approach the condition of complete combustion compared to that of a screw feeder and were in good agreement with authentication judgement standard. Furthermore, the combustion efficiency was improved according to the growth of screw pitch. The control of air flow rate from the blower and ventilator is needed to achieve the complete combustion.

A Study on PCFBD-MPC in 8kbps (8kbps에 있어서 PCFBD-MPC에 관한 연구)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.18 no.5
    • /
    • pp.17-22
    • /
    • 2017
  • In a MPC coding using excitation source of voiced and unvoiced, it would be a distortion of speech waveform. This is caused by normalization of synthesis speech waveform of voiced in the process of restoration the multi-pulses of representation section. This paper present PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) used V/UV/S( Voiced / Unvoiced / Silence ) switching, position compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. Also, I was implemented that the PCFBD-MPC( Position Compensation Frequency Band Division-Multi Pulse Coding ) system and evaluate the SNRseg of PCFBD-MPC in coding condition of 8kbps. As a result, SNRseg of PCFBD-MPC was 13.4dB for female voice and 13.8dB for male voice respectively. In the future, I will study the evaluation of the sound quality of 8kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or a smart phone.

Color Filter Based on a Sub-Wavelength Patterned Poly-Silicon Grating Fabricated using Laser Interference Lithography (광파장 이하의 주기를 갖는 다결정 실리콘 격자 기반의 컬러필터)

  • Yoon, Yeo-Taek;Lee, Hong-Shik;Lee, Sang-Shin;Kim, Sang-Hoon;Park, Joo-Do;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.20-24
    • /
    • 2008
  • A color filter was proposed and demonstrated by incorporating a subwavelength patterned 1-dimensional grating in poly silicon. It was produced by employing the laser interference lithography method, providing much wider effective area compared to the conventional e-beam lithography. A $SiO_2$ layer was introduced on top of the silicon grating layer as a mask for the etching of the silicon, facilitating the etching of the silicon layer. It was theoretically found that the selectivity of the filter was also improved thanks to the oxide layer. The parameters for the designed device include the grating pitch of 450 nm, the grating height of 100 nm and the oxide-layer height of 200 nm. As for the fabricated filter, the spectral pass band corresponded to the blue color centered at 470 nm and the peak transmission was about 40%. Within the effective area of $3{\times}3mm^2$, the variation in the relative transmission efficiency and in the center wavelength was less than 10% and 2 nm respectively. Finally, the influence of the angle of the incident beam upon the transfer characteristics of the device was investigated in terms of the rate of the relative transmission efficiency, which was found to be equivalent to 1.5%/degree.

A Study on Smart Factory System Design for Screw Machining Management (나사 가공 관리를 위한 스마트팩토리 시스템 설계에 관한 연구)

  • Lee, Eun-Kyu;Kim, Dong-Wan;Lee, Sang-Wan;Kim, Jae-joong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.329-331
    • /
    • 2018
  • In this paper, we propose a monitoring system that starts with the supply of raw materials for threading, is processed into a lathe machine, and checks for defects of the product are automatically performed by the robot with Smart Factory technology through assembly and disassembly. Completion check according to the production instruction quantity and production instruction is made by checking the production status according to whether or not the raw material is worn by the displacement sensor, and checking the pitch and the contour of the processed female and male to determine OK and NG. The robotic system acts as a relay for loading and unloading of raw materials, pallet transfer, and overall process, and it acts as an intermediary for organically driving. The location information of the threaded products is collected by using the non-contact wireless tag and the energy saving system Production efficiency and utilization rate were checked. The environmental sensor collects the air-conditioning environment data (temperature, humidity), measures the temperature and humidity accurately, and checks the quality of product processing. It monitors and monitors the driving hazard level environment (overheating, humidity) of the product. Controls for CNC and robot module PLC as a heterogeneous system.

  • PDF

Evaluation of 12nm Ti Layer for Low Temperature Cu-Cu Bonding (저온 Cu-Cu본딩을 위한 12nm 티타늄 박막 특성 분석)

  • Park, Seungmin;Kim, Yoonho;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.9-15
    • /
    • 2021
  • Miniaturization of semiconductor devices has recently faced a physical limitation. To overcome this, 3D packaging in which semiconductor devices are vertically stacked has been actively developed. 3D packaging requires three unit processes of TSV, wafer grinding, and bonding, and among these, copper bonding is becoming very important for high performance and fine-pitch in 3D packaging. In this study, the effects of Ti nanolayer on the antioxidation of copper surface and low-temperature Cu bonding was investigated. The diffusion rate of Ti into Cu is faster than Cu into Ti in the temperature ranging from room temperature to 200℃, which shows that the titanium nanolayer can be effective for low-temperature copper bonding. The 12nm-thick titanium layer was uniformly deposited on the copper surface, and the surface roughness (Rq) was lowered from 4.1 nm to 3.2 nm. Cu bonding using Ti nanolayer was carried out at 200℃ for 1 hour, and then annealing at the same temperature and time. The average shear strength measured after bonding was 13.2 MPa.

Speech Recognition Using Linear Discriminant Analysis and Common Vector Extraction (선형 판별분석과 공통벡터 추출방법을 이용한 음성인식)

  • 남명우;노승용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.35-41
    • /
    • 2001
  • This paper describes Linear Discriminant Analysis and common vector extraction for speech recognition. Voice signal contains psychological and physiological properties of the speaker as well as dialect differences, acoustical environment effects, and phase differences. For these reasons, the same word spelled out by different speakers can be very different heard. This property of speech signal make it very difficult to extract common properties in the same speech class (word or phoneme). Linear algebra method like BT (Karhunen-Loeve Transformation) is generally used for common properties extraction In the speech signals, but common vector extraction which is suggested by M. Bilginer et at. is used in this paper. The method of M. Bilginer et al. extracts the optimized common vector from the speech signals used for training. And it has 100% recognition accuracy in the trained data which is used for common vector extraction. In spite of these characteristics, the method has some drawback-we cannot use numbers of speech signal for training and the discriminant information among common vectors is not defined. This paper suggests advanced method which can reduce error rate by maximizing the discriminant information among common vectors. And novel method to normalize the size of common vector also added. The result shows improved performance of algorithm and better recognition accuracy of 2% than conventional method.

  • PDF

Electrochemical Performance of CB/SiOx/C Anode Materials by SiOx Contents for Lithium Ion Battery (SiOx 함량에 따른 CB/SiOx/C 음극재의 전기화학적 특성)

  • Kim, Kyung Soo;Kang, Seok Chang;Lee, Jong Dae;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2021
  • In this study, the composite was prepared by mixing SiOx, soft carbon, and carbon black and the electrochemical properties of lithium ion battery were investigated. The content of SiOx added to improve the capacity of the soft carbon anode material was varied to 0, 6, 8, 10, 20 wt%, and carbon black was added as a structural stabilizer for reducing the volume expansion of SiOx. The physical properties of prepared CB/SiOx/C composite were investigated through XRD, SEM, EDS and powder resistance analysis. In addition, the electrochemical properties of prepared composite were observed through the charge/discharge capacity, rate and impedance analysis of the lithium ion battery. The prepared CB/SiOx/C composite had an inner cavity capable of mitigating the volume expansion of SiOx by adding carbon black. The formed internal cavity showed a low initial efficiency when the SiOx content was less than 8 wt%, and low cycle stability when the content of SiOx was less than 20 wt%. The CB/SiOx/C composite containing 10 wt% of SiOx showed an initial discharge capacity of 537 mAh/g, a capacity retention rate of 88%, and a rate of 79 at 2C/0.1C. SiOx was added to improve the capacity of the soft carbon anode material, and carbon black was added as a structural stabilizer to buffer the volume change of SiOx. In order to use the CB/SiOx/C composite as a high-efficiency anode material, the mechanism of the optimal SiOx and the use of carbon black as a structural stabilizer was discussed.

Midterm Results of the Modified Kidner Procedure for the Symptomatic Accessory Navicular in Athletes (운동 선수에서 발생한 동통성 부주상골의 변형 Kidner 술식의 중기 결과)

  • Lee, Kyung Tai;Kim, Ki Chun;Young, Ki Won;Park, Young Uk
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.2
    • /
    • pp.82-86
    • /
    • 2012
  • Purpose: The purpose of this study was retrospectively to evaluate the results of the modified Kidner procedure for symptomatic accessory navicular in athletes. Materials and Methods: Between July 1999 and December 2004, 26 feet in 22 patients with symptomatic accessory navicular who had underwent modified Kidner procedure were available for clinical follow-up, and 12 cases in 9 patients were available for clinical and radiological follow-up with a minimum follow-up of 5 years were included in this study. All those patients had symptomatic accessory navicular bone who underwent modified Kidner procedure. American Orthopaedic Foot and Ankle Society (AOFAS) midfoot score, Visual Analogue Scale (VAS), and satisfaction rate were investigated. Talo-first metatarsal (T-MT1) angle, talo-calcaneal (TC) angle, and calcaneal pitch (CP) angle were measured in standing lateral radiograms. Results: AOFAS score was improved from $40.8{\pm}7.5$ (32~57) preoperatively to $88.7{\pm}8.0$ (72~100) postoperatively, and the difference was significant (p<0.01). VAS was improved from $7.0{\pm}0.9$ (5~9) preoperatively to $1.8{\pm}0.8$ (1~4) postoperatively, and the difference was significant (p<0.01). At the lastest follow up, 11 feet were very satisfied, 11 feet satisfied, and 4 feet unsatisfied (a satisfaction rate 85.0%). No significant difference was observed for T-MT1 angle (p=0.67), TC angle (p=0.93), and CP angle (p=0.49). Conclusion: Modified Kidner procedure for the symptomatic accessory navicular showed satisfactory results and is appeared to be one of the useful treatments.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF