• Title/Summary/Keyword: Pistol

Search Result 16, Processing Time 0.022 seconds

Measurement and analysis the peak recoil force of pistol (권총의 최대반동력 측정 및 해석)

  • Um, Hyuk
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1033-1036
    • /
    • 1996
  • In Pistol, the peak recoil force affects the reliability of the frame and the accuracy of target shooting. To attenuate the peak recoil force of pistol, we develop measuring test bed, which consists of force sensors, linear sensor and a high speed video camera, execute tests with several Pistol models and compare the results measured.

  • PDF

Establishment of The System for Checking Peak Recoil Force in a Pistol (권총의 최대반동력 측정 시스템 구축)

  • Park, Moon-Sun;Um, Hyuk;Ku, Tae-Wan;Kang, Beom-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.87-94
    • /
    • 1999
  • The peak recoil force in a pistol have an effect on the reliability of the frame and target shooting. The experimental system has been established for measurement of the peak recoil force, which consists of force and velocity sensors, high speed camera. For effective operation of the system, a software has also developed, and combined with the hardwares. Several pistols have been tested and compared quantitatively on the peak recoil force and impact energy. It is concluded that the established system can be utilzed for checking peak force, and data accumulation for new pistol design.

  • PDF

The Effects of Sight Alignment Method on Pistol Shooting Records of Security Guard (경호요원 권총사격시 조준선정렬방식과 기록변화와의 관계)

  • Lee, Sang-Chul;Shin, Seung-Cheol
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.367-388
    • /
    • 2007
  • Some of individuals working at various fields of security guard are given the legal right to use a gun to cope with expected risks and crimes. Not only in Korea but also throughout the world, a pistol is being used as a device for the workers of security guard such as the army, the police and intelligence agencies to keep the law and social order. A pistol, which is regarded as the last safety measure of security guard, is easy to carry but, because of its short barrel for high portability, its hit ratio and long-range shooting performance are much lower than ordinary guns. Despite such weak points, a pistol can be a great tool because of its high portability and if the users make steady efforts to improve their skills and, for this reason, it has been being used widely until now. National agency workers' pistol shooting skills depend on several important factors, but for the fast and accurate shooting, the mot important factor is how to aim at the target. Because it takes a relatively longer time to align the sight on the target, the change of the sight alignment method is expected to improve pistol shooting skills a lot. In Korea, however, most of national agency training centers teach the basic aiming method that crosses the foresight and the backsight and aligns the crossing to the target. That is, they teach the sight alignment method for fixed targets. Some agencies in Korea and foreign countries that have used guns more frequently and longer than us are teaching different sight alignment methods as well. Representative ones of them are aiming only with the foresight and pointing shooting. These aiming methods are expected to produce good results against moving targets. While the basic sight alignment method has to cross the foresight and the backsight and then to align the crossing to the target, so takes a longer time than other aiming methods, the other two aiming methods are expected to be effective in fields where both swiftness and accuracy are require. Because domestic agencies are teaching mainly the basic sight alignment method, the present study purposed to examine the effects of different aiming methods on shooting records and ultimately to contribute to national agency workers' operation. For this purpose, we selected 20 policemen from local police commandos under the National Police Agency who were accustomed to pistol shooting and measured their pistol shooting. According to the results, the pointed shooting method showed the best record in 5m short.range shooting. As to hit ratio in 15m shooting, which is relatively long.range for pistol shooting, the basic aiming method showed the best record, but the results of statistical analysis showed that pointed shooting is most superior. Of course, the results were obtained from a group who were used to and skillful in pistol shooting, but they are considered meaningful in that all the police and national agency workers should have such high shooting skills.

  • PDF

The Kinematic Factors of Physical Motions During Air Pistol Shooting

  • Kim, Min-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.197-204
    • /
    • 2016
  • Objective: The purpose of this study was to analyze the kinematic factors of motion during air pistol shooting. Method: This study aimed to investigate changes in forces during movement and determine the factors that affect changes in force during the first, middle, and last periods of shooting an air pistol. Two ground reaction force systems (force platform), SCATT (a shooting training system), and EMG (electromyogram) to measure the action potentials in the muscles of the upper body were used in this study. Four university air pistol players (age: 19.75 years, height: 175.50 cm, body mass: $69.55{\pm}11.50kg$, career length: $6.25{\pm}6years$) who are training to progress to a higher rank were enrolled. Results: In terms of the actual shooting results, the mean score in the middle section was $42.48{\pm}1.74$ points, higher than those in the first and the last periods when using SCATT. The gunpoint moved 13.48 mm more vertically than horizontally in the target trajectory. With respect to action potentials of muscles measured using EMG, the highest action potentials during the aiming-shooting segments, in order higher to lower, were seen in the trapezius (intermediate region), trapezius (superior region), deltoid (lateral), and triceps brachii (long head). The action potentials of biceps brachii and brachioradialis turned out to be high during grasping motion, which is a preparatory stage. During the final segment, muscle fatigue appeared in the deltoid (lateral), biceps brachii (long head), brachioradialis, and trapezius (intermediate region). In terms of the ground reaction force, during the first period of shooting, there was a major change in the overall direction (left-right $F_x$, forward-backward $F_y$, vertical $F_z$) of the center of the mass. Conclusion: The development and application of a training program focusing on muscle groups with higher muscle fatigue is required for players to progress to a higher rank. Furthermore, players can improve their records in the first period if they take part in a game after warming up sufficiently before shooting in order to heighten muscle action potentials, and are expected to maintain a consistent shooting motion continuously by restoring psychological stability.

A Study on Variation of an Accuracy Rate as the Gradient of a Pistol (총기 경사도에 따른 명중률 변화에 관한 연구)

  • Yeo, Woon-Joo;Lee, Joon-Ho;Choi, Eui-Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.167-172
    • /
    • 2011
  • In this paper, a study on variation of an accuracy rate as the gradient of a rifle is shown. In the a state of hostilities, a soldier is not easy to take a shot vertically against the ground. If a soldier shoots as the pistol is inclined, how the accuracy rate is changed. While the pistol is shot, the change of ballistic curve is estimated. And we also verify the accuracy rate through the firing test. Then we compare two results and present some ideas which overcome the decrease of an accuracy rate. Hereafter, it is possible to adapt in the future soldier system and expected that the accuracy rate of the conventional gun is maintained.

Establishment of Hysterectomy for Gnotobiotic Pig Production (무균돼지 생산을 위한 자궁적출술 확립)

  • Nho, W.G.;Lee, J.H.;Kim, W.Y.;Yeo, J.M.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.10 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • Gnotobiotic piglets were routinely produced by hysterectomy. In this study, 22 pregnant miniature pigs (111th to 113th day of gestation) were used for hysterectomy. Before surgery, 14 pigs were insensibilizated by Ketamine 50® plus CO2 gas and 8 pigs by a slaughter pistol. The high level of Ketamine 50® (0.09㎖/kg) was faster (146 vs 283 seconds) in surgery but the time taken for complete revival of one piglet was more prolonged (427 vs 64 seconds) than 0.03㎖/kg level. In hysterectomies with a slaughter pistol, surgery time was faster (470 vs 155 seconds) and the rate of alive piglets was higher (97.0 vs 83.8%) than in those with Ketamine 50®. There were no problems in the rate of alive newborn piglets even when sows were hysterectomized at 3 days prepartum.

A Study of Enemy Aptitude of Pistol Sound Source for Space Estimation (공간평가를 위한 피스톨음원의 적정성에 관한 연구)

  • Shon, Jang-Ryul;Kim, Jung-Joong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.320-328
    • /
    • 2005
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, how exactly through space sound (sound source) that wish to deliver from indoor can be passed method to do quantification and evaluate quantity of sound by method to serve indoor architectural acoustics estimation summer period and methods to estimate definition propose. This Study searches special quality of sound source about MLS signal that is occurred short-answer sound source (pistol sound source) and nondirectional speaker among indoor sound estimation method, and measure and analyzed reverberation time (RT60), definition (C80, D50) by regulation of each ISO 3382 in age place (classroom, hall, gymnasium). Analysis result and sound factor among could know that d of two sound sources converges in measurement error extent about reverberation time (RT60) of analysis incidental and sound factors and value shows change irregularly about sound factor of D50, C80, pistol sound source judged there is problem. Also, could know that problem is happened in deflection except reverberation time is in deflection analysis with wave that measure each in fixed distance in branch. Finally, when differ size of sound source and measure about change of sound pressure level in case measure sound pressure level giving difference about 10 dB, sound factor could know that there is no different effect.

Analysis of rifle and pistol primer gunshot residue using SEM-EDX (SEM-EDX에 의한 소총과 권총의 뇌관화약잔사 분석)

  • Jeon, Chung-Hyun;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.322-329
    • /
    • 2010
  • Primer gunsot residues (GSR) obtained from K1A and K2 rifles, and K5 pistol were analysed with scanning electron microscopy/energy dispersive X-ray spectrometry (SEM-EDX) as basic data in firearm accidents. Ammunition of 5.56 mm is employed for K1A and K2 rifles and 9.0 mm for a K5 pistol. The analyses of morphology, size, particle number, elemental ratio were performed for primer GSR prepared after shooting 3 times. The detected content was Ba>Pb>Sb in most GSR particles but Sb>Pb>Ba or Pb>Sb>Ba in some particles. In the statistical result of composition ratio of elements, the particles with more Sb than Ba were detected in most primer GSR from a K5 pistol, 3~8 times more than K1A and K2 rifles. This results can be employed to discriminate gun type between rifles and pistols. Furthermore, the size and the number of particles can be applied to access the type of guns.

The Kinematical Analysis between the Skilled and the Unskilled for Air Pistol Shooting Posture (공기권총 사격 자세에 대한 우수선수와 비우수선수간의 운동학적 분석)

  • Kim, You-Mi;Kim, Kab-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.509-517
    • /
    • 2009
  • The purpose of this study was to investigate the effective posture for air pistol shooting. Participants were 3 male athletes of shooting with at least five years of experience and another group of 3 males athletes with less than three years of experience. For the purpose, the shooting motion was analysed using three dimensional image technology. Data from each event for the two groups, competent and less competent ones, were compared to see the differences from the kinematical point of view. Time of period in competent group was longer than less competent group during the shooting posture. Displacement of center of mass and pistol about medial/lateral and antero/posterior in competent group was little than less competent group from aim to shooting. And these result were effect to the velocity. Distance and time in competent group within coaching machine were smaller than less competent group. To the result, it was appear that precision of aim in competent group was higher than less competent group.

Armed person detection using Deep Learning (딥러닝 기반의 무기 소지자 탐지)

  • Kim, Geonuk;Lee, Minhun;Huh, Yoojin;Hwang, Gisu;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.780-789
    • /
    • 2018
  • Nowadays, gun crimes occur very frequently not only in public places but in alleyways around the world. In particular, it is essential to detect a person armed by a pistol to prevent those crimes since small guns, such as pistols, are often used for those crimes. Because conventional works for armed person detection have treated an armed person as a single object in an input image, their accuracy is very low. The reason for the low accuracy comes from the fact that the gunman is treated as a single object although the pistol is a relatively much smaller object than the person. To solve this problem, we propose a novel algorithm called APDA(Armed Person Detection Algorithm). APDA detects the armed person using in a post-processing the positions of both wrists and the pistol achieved by the CNN-based human body feature detection model and the pistol detection model, respectively. We show that APDA can provide both 46.3% better recall and 14.04% better precision than SSD-MobileNet.