• 제목/요약/키워드: Piping vibration

검색결과 171건 처리시간 0.025초

스트레인게이지를 활용한 발전소 터빈 및 주증기 배관의 열팽창 측정 (Thermal Expansion Measurement of Turbine and Main Steam Piping by Using Strain Gages in Power Plants)

  • 나상수;정재원;봉석근;전동기;김윤석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.886-891
    • /
    • 2000
  • One of the domestic co-generation plants have undergone excessive vibration problems of turbine attributed to external force for years. The root cause of turbine vibration may be shan alignment problem which sometimes is changed by thermal expansion and external farce, even if turbine technicians perfectly performed it. To evaluate the alignment condition from plant start-up to full load, a strain measurement of turbine and main steam piping subjected to thermal loading is monitored by using strain gages. The strain gages are bonded on both bearing housing adjusting bolts and pipe stoppers which. installed in the x-direction of left-side main steam piping near the turbine inlet in order to monitor closely the effect of turbine under thermal deformation of turbine casing and main steam piping during plant full load. Also in situ load of constant support hangers in main steam piping system is measured by strain gages and its results are used to rebalance the hanger rod load. Consequently, the experimental stress analysis by using strain gages turns out to be very useful tool to diagnose the trouble and failures of not only to stationary components but to rotating machinery in power plants.

  • PDF

습분분리재열기 배수관 진동저감방안 (Vibration Reduction Method for Discharge Line of Moisture Separator Reheater)

  • 이준신;손석만;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

배영계의 진동해소를 위한 주파수종속 요표행렬 (Frequency-Dependent Element Matrices for Vibration Analysis of Piping Systems)

  • 양보석;안영홍;최원호
    • 한국해양공학회지
    • /
    • 제6권2호
    • /
    • pp.125-132
    • /
    • 1992
  • This paper presents an approach for the derivation of frequency-dependent element matrices for vibration analysis of piping systems containing a moving medium. The dynamic stiffness matrix is deduced from transfer matrix, and, in turn, the frequency-dependent element matrices are derived. Numerical examples show that method gives more accurate results than those obtained using the conventional static shape function based element matrices.

  • PDF

내부에 유체가 흐르는 파이프계의 동적안정성 및 응답해석 (Dynamic Stability and Response Analysis of Piping System with Internal Flow)

  • 이우식;박철희;홍성철
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.1861-1871
    • /
    • 1991
  • 본 연구에서는 아직까지 연구가 미진한 내용 즉, 유속과 압력이 시간과 위치 의 함수인 유동특성과 파이프의 운동이 상호 연계되어 영향을 주는 일반적인 경우의 운동방정식을 유도하였고 단순지지된 직선 파이프를 모델로 설정하여 동적 안정성 (dynamic stability)과 진동응답을 수치적으로 고찰하였다.

발전소의 대형 주증기배관의 진동 특성 (The Vibration Characteristic of Large Main Steam Pipelines in Power Plant)

  • 김연환;이현
    • 소음진동
    • /
    • 제6권6호
    • /
    • pp.709-715
    • /
    • 1996
  • In recent years, the piping vibration in many Power Plants is being increased by the aged generating facilities due to a long time use. Generally, the pressure fluctuations associated with the flow-induced excitations in this case are broadband in nature. Mainly, the dominant sources of vibration are a vortex-shedding, plane waves and boundary layer turbulence. The peak level of the spectrum is proportional to the dynamic head. A severe disturbance in pipeline results in the generation of intense broadband internal sound waves which can propagate through the piping system. The characteristic frequencies of operating loads of 20%, 57%, 70%, 100% are 4 - 6 Hz and coincide with the results from impact hammering test and FEM analysis. We chose the wire energy absorbing rope restraint as a vibration reduction method after reviewing the various conditions such as site, installing space and economic cost etc. After installation, the vibration level was reduced about 54% in velocity.

  • PDF

곡관 종류에 따른 배수관내의 소음 저감에 관한 실험적 연구 (Experimental Study on the Noise Reduction of Drainage Pipe by a kind of Curve Pipe)

  • 김정훈;심동혁;김경훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.187-192
    • /
    • 2006
  • The effect where the multiple sound arrest ing goes mad to the human being does the zone. From like that cotton, this dissertation the both sides flag executed the research regarding a sound arresting reduction in the object in one example. It compared the piping structure which generally is space-time and a specific piping structure and it tested and research and the modeling regarding a sound arresting reduction the simulation which leads and it executed result and comparison of existing it analyzed. The duplication where the reduction effect is bigger the result general VG2 piping structure than escape it did with the fact that it appears the large effect the piping structure which it connects. Also, the straight pipe effect of multiple sound arresting could not go mad with the fact that.

  • PDF

맥동류에 의한 파이프 계의 진동응답에 관한 연구 (A Study on the Vibration Responses of Piping Systems by Pulsation Flow)

  • 이동명;최명진
    • 한국음향학회지
    • /
    • 제16권6호
    • /
    • pp.68-75
    • /
    • 1997
  • 본 연구에서는 맥동류에 의한 파이프 계의 진동응답을 고찰하기 위해 전달행렬법을 사용하였다. 유속과 압력을 시간과 위치의 함수로 다루어 유체와 파이프간의 상호작용을 파동방정식으로 정립하고, 각 파동방정식으로부터 전달행렬을 직접 유도하였다. 맥동류로부터 유발되는 파이프 계의 동적응답은 맥동으로부터 발생하는 변동유속과 압력에 의존되는 것으로 나타났으며, 공진 근처에서 맥놀이 현상이 관찰되었다. 파이프 계의 동적거동은 파이프 내부의 유동양상과 동일한 응답특성을 나타내고, 내부 유동유체에 의해 결정된다.

  • PDF

Wire Rope형 배관 지진$\cdot$진동완충기의 설계 (Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System)

  • 김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF

수위변화에 따른 파이프 시스템의 진동 특성 변화에 대한 연구 (A research on Dynamic characteristic of Submerged pipe ; Support, Flange, Upper pump)

  • 정휘권;김종윤;박규해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.699-705
    • /
    • 2013
  • This paper presents vibration testing, control, and finite element analysis of a piping system, which is subjected to the changes in fluid levels. Nuclear power plants typically employ a cooling system that uses sea water. These systems are subjected to dynamic characteristic changes caused by sea-level variations, which introduces failures of cooling system components. Therefore in this study, analytical and experimental studies were performed to understand the effect of sea-level changes on the dynamic characteristics of piping systems. It was shown that, as the sea-level increases, pipe's natural frequencies decreases in relation to its mode shape. A 1/14 scale model was also built to compare the results obtained by the analytical study. A good agreement between experiment and analytical studies were observed. Finally, an on-line resonant frequency identification system was proposed and developed, which utilizes piezoelectric transducers as sensors and actuators, in order to avoid catastrophic failure of piping systems.

  • PDF

Non-contact monitoring of 3-dimensional vibrations of bodies using a neural network

  • Ha, Sung Chul;Cho, Gyeong Rae;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권10호
    • /
    • pp.1011-1016
    • /
    • 2015
  • Gas piping systems in power plants and factories are always influenced by the mechanical vibrations of rotational machines such as pumps, blowers, and compressors. Unusual vibrations in a gas piping system influence possible leakages of liquids or gases, which can lead to large explosive accidents. Real-time measurements of unusual vibrations in piping systems in situ prohibit them from being possible leakages owing to the repeated fatigue of vibrations. In this paper, a non-contact 3-dimensional measurement system that can detect the vibrations of a solid body and monitor its vibrational modes is introduced. To detect the displacements of a body, a stereoscopic camera system is used, through which the major vibration types of solid bodies (such as X-axis-major, Y-axis-major, and Z-axis-major vibrations) can be monitored. In order to judge the vibration types, an artificial neural network is used. The measurement system consists of a host computer, stereoscopic camera system (two-camera system, high-speed high-resolution camera), and a measurement target. Through practical application on a flat plate, the measured data from the non-contact measurement system showed good agreement with those from the original vibration mode produced by an accelerator.