• Title/Summary/Keyword: Piping vibration

Search Result 171, Processing Time 0.024 seconds

Written Plan of CVAP Design Control Document for APR1400 U.S. Design Certification (APR1400 미국 설계인증을 위한 종합진동평가 심사서류 작성 방안)

  • Ko, Do Young;Kim, Dong Hak;Park, Young Sheop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.102-105
    • /
    • 2014
  • In accordance with U.S. Nuclear Regulatory Commission regulatory guide(NRC RG) 1.20(Rev.3), we are writing a comprehensive vibration assessment program(CVAP) design control document(DCD) and a technical report for U.S. NRC design certification(DC) of an Advanced Power Reactor 1400(APR1400) nuclear power plant(NPP). CVAP of an APR1400 NPP for U.S. NRC DC is classified as a non-prototype category 1 type. Therefore, CVAP DCD of reactor vessel internals(RVI) and steam generator internals(SGI) consist of analysis and full inspection program. However, piping system of primary and secondary system will be described as measurement program.

  • PDF

Detecting steam leakage by using correction of camera vibrating (카메라 흔들림 보정을 통한 증기 누설 탐지)

  • Choi, Young-Chul;Yoon, Chan-Hoon;Kim, Jin-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.394-398
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

  • PDF

Correction of Error due to Camera Vibrating During Detecting Steam Leakage by Using Image (영상을 이용한 누설탐지에서 카메라 진동 오차 보정)

  • Choi, Young-Chul;Jeon, Hyeong-Seop;Son, Ki-Sung;Park, Jong Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.795-801
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

A review of fatigue failures in LWR plants in Japan

  • Kunihiro, Iida
    • Proceedings of the KWS Conference
    • /
    • 1996.10a
    • /
    • pp.19-34
    • /
    • 1996
  • A review was made of fatigue failures of nuclear power plant components in Japan, which were experienced in service and during periodical inspection. No case has been recently reported of a service fatigue failure of a reactor pressure vessel itself, excluding nozzle corner cracks, that occurred many years ago. But, service fatigue failures have been occasionally experienced in piping systems, pumps, and valves, on which fatigue design seems to have been inadequately applied. The causes of fatigue failures can be divided into two categories: mechanical-vibration-induced fatigue and thermal-fluctuation-induced fatigue. Vibration-induced fatigue failure occurs more frequently than is generally thought. The lesson gleaned from the present survey is a recognition that a service fatigue failure may occur due to any one or a combination of the following factors: (1) lack of communication between designers and fabrication engineers, (2) lack of knowledge about a possibility of fatigue failure and poor consideration about the effects of residual stresses, (3) lack of consideration on possible vibration in the design and fabrication stages, and (4) lack of fusion or poor penetration in a welded joint.

  • PDF

Experimental evaluation of fatigue strength for small diameter socket welded joints under vibration loading condition

  • Oh, Chang-Young;Lee, Jun-Ho;Kim, Dong-Woo;Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3837-3851
    • /
    • 2021
  • To investigate how the fabrication and repair of socket welded joints could be used to enhance fatigue resistance under vibration condition, experimental test data of installation conditions that potentially influence fatigue strength were analyzed with the S-N curve. It was found that the decreasing fatigue strength of stainless steel socket welded joints was attributed to the effect of high heat input of welding process. The effect of welding method, slip-on gap and radial-gap conditions on fatigue strength was insignificant. The test data of repair technique application, 2 × 1 leg length and of socket weld overlay, clearly showed higher fatigue strength but there was a limitation for higher stress region because of the weld toe crack.

Vibration control for serviceability enhancement of offshore platforms against environmental loadings

  • Lin, Chih-Shiuan;Liu, Feifei;Zhang, Jigang;Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.403-414
    • /
    • 2019
  • Offshore drilling has become a key process for obtaining oil. Offshore platforms have many applications, including oil exploration and production, navigation, ship loading and unloading, and bridge and causeway support. However, vibration problems caused by severe environmental loads, such as ice, wave, wind, and seismic loads, threaten the functionality of platform facilities and the comfort of workers. These concerns may result in piping failures, unsatisfactory equipment reliability, and safety concerns. Therefore, the vibration control of offshore platforms is essential for assuring structural safety, equipment functionality, and human comfort. In this study, an optimal multiple tuned mass damper (MTMD) system was proposed to mitigate the excessive vibration of a three-dimensional offshore platform under ice and earthquake loadings. The MTMD system was designed to control the first few dominant coupled modes. The optimal placement and system parameters of the MTMD are determined based on controlled modal properties. Numerical simulation results show that the proposed MTMD system can effectively reduce the displacement and acceleration responses of the offshore platform, thus improving safety and serviceability. Moreover, this study proposes an optimal design procedure for the MTMD system to determine the optimal location, moving direction, and system parameters of each unit of the tuned mass damper.

A Study on Seismic Restraint of Korean Type Building Gas Piping (한국형 건축물 가스 배관의 내진 고정장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2019
  • This study relates to a fixing device for gas piping installed in a building such as an apartment or a building. The gas piping is fixed to the inside of the housing so as to buffer the gas piping in all directions, thereby relieving vibration caused by an earthquake or an impact, Disclosed is an earthquake-proof fixing device for a gas pipeline that can minimize damages caused by damage to an earthquake and a gas pipeline by preventing damage and breakage. An apparatus for fixing a gas pipe to a bracket provided on a wall or a wall of a building, the apparatus comprising: a housing coupled to a wall or a bracket and coupled to the inside of the housing; a gas pipe penetrating through the housing to fix the gas pipe; The first plate spring includes a first plate spring formed with a plurality of concave-convex portions that are elastically supported in four directions. The first plate spring is screwed to the front surface or the rear surface of the housing. The lower plate is coupled to one end and the other end, And a pair of first adjusting screws for adjusting the elastic force of the spring. Through this study, damage and damage of gas piping due to earthquake or impact can be minimized.

Leak Detection of Circular Piping Systems by Using Unit Impulse Response Function Analysis (단위 충격 응답함수를 이용한 원형관 시스템의 주출감지 연구)

  • 전오성;윤병옥;김창호
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.337-343
    • /
    • 1994
  • A method of the leak detection from the pipe system by using accelerometer is proposed. The signal detected from accelerometer is proved experimentally to be a dispersive wave. Based on the experiments, a method using the narrow band pass filter and the unit impulse response function is analyzed. The method uses the characteristics of the unit impulse response function, that the function is available evenin the narrow band signal because, unlike the cross correlation, it is normalized by the auto spectrum. The accelerometer is quite easier to use than the hydrophone in adapting to the pipe system.

  • PDF

Monitoring and vibration control of a fluid catalytic cracking unit

  • Battista, Ronaldo C.;Varela, Wendell D.;Gonzaga, Igor Braz N.
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.577-588
    • /
    • 2022
  • Oil refineries' Fluid Catalytic Cracking Units (FCCU) when in full operation may exhibit strong fluid dynamics caused by turbulent flow in the piping system that may induce vibrations in other mechanical and structural components of the Unity. This paper reports on the experimental-theoretical-computational program performed to get the vibration properties and the dynamic response amplitudes to find out alternative solutions to attenuate the excessive vibrations that were causing fatigue fractures in components of the bottle like reactor-regenerator of an FCC unit in operation in an existing oil refinery in Brazil. Solutions to the vibration problem were sought with the aid of a 3D finite element model calibrated with the results obtained from experimental measurements. A short description of the found solutions is given and their effectiveness are shown by means of numerical results. The solutions were guided by the concepts of structural stiffening and dynamic control performed by a nonlinear pendulum controller whose mechanical design was based on parameters determined by means of a parametric study carried out with 2D and 3D mathematical models of the coupled pendulum-structure system. The effectiveness of the proposed solutions is evaluated in terms of the fatigue life of critical welded connections.

Monitoring Method for Pipe Thinning using Accelerometers (가속도계를 이용한 배관 감육 감시 방법)

  • Choi, Young-Chul;Park, Jin-Ho;Yoon, Doo-Byung;Sohn, Chang-Ho;Hwang, Il-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.156-162
    • /
    • 2006
  • Pipe thinning is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. In this paper, we proposed the method for monitoring pipe thinning. Our basic idea come from that a group velocity of impact wave is different as wall thickness. If the group velocity is measured, wall thickness can be estimated. To obtain the group velocity, time-frequency analysis is used. This is because an arrival time difference can be measured easily in time-frequency domain rather than time domain. To test the performance of this technique, experiments have been performed for a plate and U type pipe. Results show that the proposed technique is quite powerful in the monitoring pipe thinning.

  • PDF