• 제목/요약/키워드: Piping system

검색결과 777건 처리시간 0.023초

CAD 정보를 활용한 해양 배관재 설치 준비율 관리 방법에 관한 연구 (A Study on the Installation Readiness Management Method of Offshore Plant using CAD Information)

  • 박중구;김호정;김민규;박지찬
    • 대한조선학회논문집
    • /
    • 제56권2호
    • /
    • pp.152-160
    • /
    • 2019
  • In this study, we propose a piping material supply management method using CAD system. The piping materials installed in super large offshore plants have very complicated connection conditions. Therefore, it is very difficult to determine the order of receipt of a large number of installation materials. Therefore, we have developed a system that can automatically check the preparation rate of installation materials prior to the installation process. We have developed an algorithm to obtain connection information among installation items from PDMS system. We have developed an algorithm that can determine the order of installation materials to be installed using the connection information. The order of the installation material is determined by taking into account the constraint conditions for the complete installation of the piping material. We confirm the effectiveness of the developed algorithms in the operating system. This system is also used to manage installation schedules and plan the installation manpower.

해수연결 배관계 소음감소기의 투과손실 측정에 관한 연구 (A Study on Determining the Transmission Loss of Water-Borne Noise Silencer in a Sea-Connected Piping System)

  • 박경훈
    • 한국음향학회지
    • /
    • 제26권6호
    • /
    • pp.286-292
    • /
    • 2007
  • 해수연결 배관계에서 발생되는 주요한 소음원은 함 내부 탑재장비의 원활한 작동을 위해 해수를 순환시키는 해수순환 펌프이다. 이러한 펌프에서 발생되는 토널 성분을 가지는 유체전달 소음은 적절한 소음감소기를 통해서 감소되어야 한다. 본 논문에서는 실험적으로 유체전달 소음감소기의 음향 투과손실을 측정하기 위해서 해수연결 배관계의 끝단 반사가 존재하는 경우 배관 내의 음파를 입사파와 투과파로 분리하는 전달함수 기법을 제안하였다. 제작된 소음감소기 시험시편에 대한 이론적 투과손실과 제안된 기법을 통해 측정된 투과손실이 관심 주파수 영역에서 잘 일치함을 확인함으로써 기법의 타당성을 검증하였다.

원자력배관 건전성평가 전문가시스템 개발(II) -시스템 개발 및 사례해석- (Development of Nuclear Piping Integriry Expert System (II) -System Development and Case Studies-)

  • 전현규;허남수;김영진;박윤원;최영환
    • 대한기계학회논문집A
    • /
    • 제25권6호
    • /
    • pp.1015-1022
    • /
    • 2001
  • The objective of this paper is to develop an expert system called NPIES for nuclear piping integrity. This paper describes the structure and the development strategy of the NPIES system. The NPIES system consists of 3 part; the data input part, the analysis part and the output part. The data input part consists of the material properties database module and the suer interface module. The analysis part consists of the LEFM, CDFD, J/T, limit load modules and the 12 analysis routines for different cracks and loading conditions are provided respectively. Analysis results are presented to screen, printer and text file in the output part. Several case studies on circumferentially cracked piping were performed to evaluate the accuracy and the usefulness of the code. Maximum piping loads predicted by the NPIES system agreed well with those by the 3-dimensional finite element analysis. In addition, even if the material properties were not fully given, the NPIES system provided reasonable evaluation results with the predicted material properties inferred from the material properties database module.

국내원전 배관계통 열성층 연구개발 현황 (Status of Thermal Stratification Research on Piping System in Korea Nuclear Power Plant)

  • 이선기
    • 한국압력기기공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.25-33
    • /
    • 2016
  • The thermal stratification phenomenon in the nuclear power plant can cause abnormal deformation of the piping, contact with the support, damage to the support system. Repetition of the thermal stratification phenomenon or variation of the thermal boundary layer can cause thermal fatigue. Thermal stratification phenomenon in nuclear power plants is still an ongoing issue and active research has been carried out. In this paper, the current situation in Korean nuclear power plants is described, followed by the status of research and the future problems on the thermal stratification phenomenon in Korea.

급수 배관계의 음향진동 현상 고찰 및 대책 (Mechanism Investigation and Measures on Acoustic Vibration Phenomena of Water Supply Piping)

  • 김연환;배용채;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.470-475
    • /
    • 2012
  • The downstream piping system of the water supply system in a supercritical power plant is affected by the fluctuation pressure waves induced by accessing to the acoustic modes of the piping systems with the rotation and impeller passing pulsations of the feed water pump. There are the phenomena amplified at the same time in the range of 415 ~ 455Hz, 830 ~ 910Hz, 1245 ~ 1365Hz and 1660 ~ 1820Hz on the spectrums of the vibration, the sound pressure, and the pressure fluctuation waves.

  • PDF

감육 배관의 다양한 보강 형태에 따른 이론적 등가 강성 검증 (Analytical Equivalent Stiffness Analysis for Various Reinforcements of Wall-thinned Pipe)

  • 장제훈;김지수;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.11-18
    • /
    • 2022
  • When wall-thinning in a pipe occurs during operation of nuclear power plant, reinforcement of the pipe needs to be performed. Accordingly, the structural response of the piping system due to introduction of the reinforcement may be re-evaluated. For elastic structural analysis of the piping system with the reinforced pipe using finite element (FE) analysis, the stiffness of the reinforced pipe is needed. In this study, the stiffness matrix of wall-thinned pipe with pad reinforcement or composite reinforcement is analytically derived. The validity of the proposed equations is checked by comparing with systematic finite element (FE) analysis results.

사무소 건축물의 건축기계설비 배관 부속자재 요율 산출 (Calculation of the Attached-Piping-Material Rate for the Building Mechanical-Service System in Office Buildings)

  • 박률
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.185-194
    • /
    • 2017
  • Currently, in comparison with other architectural estimations, the estimation work regarding building mechanical-service systems is time-consuming, and the process is continuously becoming more difficult because of the increased usage of the attached piping materials such as fittings and hangings in addition to their complicated construction processes. To improve this problem, the Korean authority provides a simple estimation method for the attached-material rate regarding the main piping material, which is the most time-consuming work in the architectural-mechanical estimation. However, to be an applicable method on construction sites, a proper conversion rate of the attached-piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the calculation of the rate of the attached-piping materials such as the fittings and supports through the building of the mechanical-service work types of mechanical rooms, air conditioning, domestic water and hot-water supplies, and the drain-, vent-, and gas-piping work in office buildings that have been designed after 2010.

밀폐배관계에 있어서의 열팽창에 대한 안전설계 및 시스템 최적 설정에 관한 고찰 (A Study on Safety Engineering & System Optimization in the Closed Piping System)

  • 차순철;황순용;강경식
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2007
  • To improve the practical application of the thermal expansion of closed long pipeline exposing to external heating sources such as solar energy, safety engineering and system optimization for relief valve in the closed piping system are suggested through theoretical approach, correlation in view of temperature and pressure increase caused by external solar energy in the closed piping system. The profile for thermal relief valve including relieving capacity, influx heat energy, sizing criteria, set pressure, selection against back pressure is also presented. It is noted that following topic on solar relief valve should be applied to engineering, installation and commissioning.

원전 내 배관의 증기 누설 사고 시 누설 탐지 포집/이송 시스템 예비 해석 (Preliminary Analysis of a Sampling and Transportation System for Leak Detection during Steam Leak Accident of a Pipe in Nuclear Power Plants)

  • 최대경;최청열;권태순;어동진
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.25-34
    • /
    • 2020
  • As leakage in nuclear power plants could cause a variety of problems, it is very critical to monitor leakage from the safety point of view. Accordingly, a new type of leak detection system is currently being developed and flow characteristics of the sampling and transportation system are investigated by using numerical analysis as a part of the development process in this study. The results showed that the steam mass fraction varied according to the effect of the gap between the insulation and piping component, transportation velocity, and material properties of porous media during the sampling and transportation process. The results of this study should be useful for understanding flow characteristics of the sampling and transportation system and its design and application.

산업플랜트 배관계통의 해석 및 설계시스템 개발에 관한 연구 (A Study on the Development of the Computer Aided Analysis and Design System of the riping Networks of Industrial Plants)

  • 유종열;최창근;이종원;오재화
    • 대한설비공학회지:설비저널
    • /
    • 제6권4호
    • /
    • pp.262-266
    • /
    • 1977
  • A new computer system for the stress analysis and design of piping network has been devlo-ped in this study. For the stress analysis, the system utilizes the finite element technique in which the frontal technique is used as the equation solver. The element library of the system has (1) Pipe Element (2) Beam Element, (3) Hanger Element and (4) Spring Element which should be sufficient to model the entire piping system including flexible supports, joints, piping rack and hangers. Based on the element stresses, code check has been performed and the safety factor for each element is calculated.