• Title/Summary/Keyword: Piping structure

Search Result 144, Processing Time 0.028 seconds

A Case Study on Construction Cost Comparison for On-Site Construction and Off-Site Construction of Plant Project (플랜트 건설의 현장시공 및 모듈시공에 대한 공사비 비교 사례연구 - Pipe Rack을 대상으로 공사비 산정 -)

  • Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.25-34
    • /
    • 2023
  • The purpose of this study is to calculate and compare construction costs for On-Site Construction and Off-Site Construction in Plant Project. For this purpose, the target for calculating the construction cost was limited to the Pipe Rack(Steel Structure and Piping). The results derived according to the purpose of the study are as follows. 1)The direct construction cost for On-Site Pipe Rack construction was KRW 56 billion, with Steel Structure KRW 25.1 billion and Piping KRW 30.8 billion won. 2)Comparing the rate of change between On-Site Construction and Off-Site Construction, material costs increased by 1.9% and expenses by 192.1%, but labor costs decreased by -9.1%, resulting in a total direct construction cost increase of 8.4%. These results can be used as reference data to check the current status of the increase or decrease in construction costs when constructing Pipe Racks as Off-Site Construction.

Failure Analysis on High Pressure Steam Piping of 500 MW Thermal Power Plant (500 MW 화력발전소 고압 증기 배관 손상 원인 분석)

  • Kim, Jeongmyun;Jeong, Namgeun;Yang, Kyeonghyun;Park, Mingyu;Lee, Jaehong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.323-330
    • /
    • 2019
  • The 500 MW Korean standard coal-fired power plant is the largest standardized power plant in Korea and has played a pivotal role in domestic power generation for over 20 years. In addition to the aging degradation due to long term operation, the probability of failure of power generation facilities is increasing due to frequent startup and stop caused by the lower utilization rate due to air pollution problem caused by coal-fired power plants. Among them, steam piping plays an important role in transferring high-temperature & pressure steam produced in a boiler to turbine for power generation. In recent years, failure of steam piping of large coal-fired power plant has frequently occurred. Therefore, in this study, failure analysis of high pressure piping weld was conducted. We identify the damage caused by high stress due to abnormal supporting structure of the piping and suggest improved supporting structure to eliminate high stress through microstructure analysis and piping stress analysis to prevent the occurrence of the similar failure of other power plant in the case of repetitive damage to the main steam piping system of the 500 MW Korean standard coal-fired power plant.

Structural Safety Assessment of Piping Used in Offshore Plants According to Thermal Load and Motion (해양플랜트에 사용되는 배관의 열 하중과 구조물의 운동에 따른 구조안전성 평가)

  • Ryu, Bo Rim;Kang, Ho Keun;Duong, Phan Anh;Lee, Jin Uk
    • Journal of Navigation and Port Research
    • /
    • v.45 no.4
    • /
    • pp.212-223
    • /
    • 2021
  • The objective of this study was to evaluate structural safety according to environmental conditions acting on the piping of offshore structure and the motion of the structure. As for conditions acting on the piping, the maximum and minimum temperature conditions were used to analyze the design conditions of N2 generator. The motion of the structure was calculated and applied according to the DNV(Det Norske Veritas) rule. Each condition was combined and a total of 26 load combinations were constructed according to thermal load, motion load, and presence or absence of pipe support. Analysis was performed using a commercial program MSC Patran/Nastran. Thermal analysis was performed by applying the steady-state method, Sol 153. Thermal-structural coupled analysis was performed using Sol 101, a linear-static method. As a result of the analysis, the stress tended to increase when temperature inside the pipe was lower in Set 1 and Set 2, when temperature was higher in Set 3, and when the temperature difference between the inside and outside of the pipe in Set 4 was increased. However, the sum of stresses in the condition with only temperature load and the condition with only the kinetic load did not show the same value as the stress in the composite load condition of two loads. That is, the influence of the motion load varied depending on the direction of motion, the arrangement of pipes, and the position of the support. Therefore, it is necessary to comprehensively consider the size and direction of the motion load acting on the piping, the arrangement of the piping, and the location of the pipe supports during the design of piping.

Experimental Study on the Blade Excitation Frequency for the Natural Frequence of Centrifugal Pump Piping Systems (원심펌프 배관계 진동에 영향을 주는 블레이드 가진주파수의 실험적 고찰)

  • 김윤제;신호길
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.335-341
    • /
    • 2001
  • Pressure pulsations generated by the blade-tongue interaction induce vibration of the piping systems and the structure connected to pumps, resulting in the severe noise and fatigue fracture. Experiments were made on the natural frequencies of liquid columns in piping systems with a single suction, single stage, centrifugal volute pump. Experimental results show that the natural frequencies of the liquid columns in the pump piping systems depend on the dimensions of the pipes and the impeller shapes, and are not affected substantially by the rate of discharge and the rotating speed of the pump.

  • PDF

Against Pied-Piping

  • Choi, Young-Sik
    • Language and Information
    • /
    • v.6 no.2
    • /
    • pp.171-185
    • /
    • 2002
  • I claim that the asymmetry of locality effects in wh-questions involving Complex Noun Phrase Island in Korean follows from the proposal for the asymmetric mode of scope taking between way (why) and the other wh-words in Korean as laid out in Choi (2002). 1 will show that the present proposal is superio. to the LF pied-piping approach in Nishigauchi (1990) and WH-structure pied-piping in von Stechow(1996) in that it does not have the fatal problem of wrong semantics in Nishigauchi and Subjacency violation problem in von Stechow. The crossed reading in examples involving Wh-island has an interesting implication for the mechanism of unselective binding, suggesting that Heim's (1982) quantifier indexing mechanism, which requires the local unselective binding of the indefinite by the unselective binder, may be too strong.

  • PDF

Case study on the reduction of airborne and structure-borne noise of a shipboard pump (함정탑재 펌프류 장비의 공기음/고체음 저감 사례 연구)

  • Kim, Sang-Ryul;Kim, Hyun-Sil;Kim, Bong-Ki;Kim, Jae-Seung;Kang, Hyun-Ju
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.411-415
    • /
    • 2007
  • The reduction of airborne and structure-borne noise of a shipboard pump for a navel ship is very important because the noise levels of the pump must not exceed criteria such as MIL-STD. In this paper, several practical examples of reducing the noise levels are presented. The examples show that the inadequate rotor-balancing and shaft-alignment results in the increase of the structure-borne noise on all lower mounts. It is also found that the unequal loading on mounts can cause the dramatically increasing the noise levels on certain local positions. Since the piping system arrangement such as valve location, flexible joint, and elbow location affects on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system.

  • PDF

An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity (도시가스 매설이중배관 건전성 향상에 관한 실험적 연구)

  • Lim, Hyung-Duk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header (주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

EFFICIENT ANALYSOS OF PIPING SYSTEMS WITH JOINT DEFORMATION (접합부의 변형을 고려한 파이프 설비의 효율적인 해석)

  • 이동근;김남식;송윤환;이경훈
    • Computational Structural Engineering
    • /
    • v.2 no.3
    • /
    • pp.105-114
    • /
    • 1989
  • A piping system is a structure composed of pipes with various thickness, diameter and length. Accurate analysis of a piping system requires a complicated three dimensional finite element model and a computer system with large memory size, while a simplified model may result in system response prediction with deteriorated accuracy. An efficient analysis model for piping systems is proposed in the present study. The proposed model is developed by introducing pipe joint elements which accounts for the behavior of a pipe joint. Pipes are represented by beam elements and the effect of local deformation of pipe joints is replaced by joint element deformations. The proposed model which is as simple and efficient as a beam model can be used to obtain piping system response with accuracy close to that of a finite element model.

  • PDF

A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes (일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구)

  • Baek, Yeal-Sun;Nam, Jun-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.65-70
    • /
    • 2017
  • The seismic performance of press fittings is studied, which is one of the weldless joints of stainless steel pipe used in the water piping of recent fire protection system. The piping of this study was constructed based on the piping connection reference of NFPA 13. The permissible displacement of the piping was set as the allowed amount which is given in the Building Structure Standard, and the measurements were repeated 10 times. The Von-mises stress of the piping was 2.48 and 1.25 times of the allowed amount of stress, which was less than the standard, noted three times on the NPPs Allowable Stress for Level D service loading. Therefore, the press fittings shows enough seismic performance.