• 제목/요약/키워드: Piping design system

검색결과 262건 처리시간 0.021초

Case Study of Non-Metallic Repair Systems for Metallic Piping

  • Hammad, Bakr. S.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.6-12
    • /
    • 2008
  • Non-metallic composite overwrap repair methods utilize resin based fiber-reinforced composite materials, which have higher specific strength to weight ratio and stiffness, superior corrosion and fatigue resistance, and substantially reduced weight when compared to carbon steel. Non-metallic repair methods/systems can allow desired functional properties to be achieved at a respectable economic advantage. For example, non-metallic composite repair systems have at least a 50 year design stress of 20 ksi and approximately 25% of the short term tensile strength of fiberglass. For these systems, the contribution of the repaired steel to the load carrying capability need not be considered, as the strength of the repair itself is sufficient to carry the internal pressure. Worldwide experience in the Oil & Gas industry confirms the integrity, durability, inherent permanency, and cost-effectiveness of non-metallic composite repair or rehabilitation systems. A case study of a recent application of a composite repair system in Saudi Aramco resulted in savings of 37% for offshore subsea line and 75% for onshore above grade pipeline job. Maintaining a pipeline can be costly but it is very small in comparison to the cost of a failure. Pipeline proponents must balance maintenance costs with pipeline integrity. The purpose is not just to save money but also to attain a level of safety that is acceptable. This technology involves the use of an epoxy polymer resin based, fiber-reinforced composite sleeve system for rehabilitation and /or repair pipelines.

원자력 발전소용 입형 사류펌프의 동적해석에 관한 연구 (A Study on Dynamic Analysis of Vertical Mixed-Flow Pump for Nuclear Power Plants)

  • 서영수;임우섭;정희택
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.71-77
    • /
    • 2006
  • This study introduces the seismic qualification of safety related equipments for nuclear power plants to verify the possibility of resonance in regard to the operating speed and the structural integrity due to external piping nozzle loads as well as seismic dynamic loads using El-Centro earthquake, which was occurred in the 1940's previously. As a first step, it is necessary to investigate the natural frequency of the vertical mixed flow pump in order to determine whether static or dynamic equipment comparing with seismic cut-off frequency, 33hz. Also the normal mode analysis was carried out with the introduction of seismic redesign straint at the middle of vertical pump to increase the natural frequency. In terms of structural integrity, the application of static analysis with normal, upset and faulted nozzle loads event was presented for the comparison of material allowable stress. Also the dynamic analysis was performed to show the design adequacy through the application to the case of El-Centro earthquake.

  • PDF

Monitoring and vibration control of a fluid catalytic cracking unit

  • Battista, Ronaldo C.;Varela, Wendell D.;Gonzaga, Igor Braz N.
    • Smart Structures and Systems
    • /
    • 제29권4호
    • /
    • pp.577-588
    • /
    • 2022
  • Oil refineries' Fluid Catalytic Cracking Units (FCCU) when in full operation may exhibit strong fluid dynamics caused by turbulent flow in the piping system that may induce vibrations in other mechanical and structural components of the Unity. This paper reports on the experimental-theoretical-computational program performed to get the vibration properties and the dynamic response amplitudes to find out alternative solutions to attenuate the excessive vibrations that were causing fatigue fractures in components of the bottle like reactor-regenerator of an FCC unit in operation in an existing oil refinery in Brazil. Solutions to the vibration problem were sought with the aid of a 3D finite element model calibrated with the results obtained from experimental measurements. A short description of the found solutions is given and their effectiveness are shown by means of numerical results. The solutions were guided by the concepts of structural stiffening and dynamic control performed by a nonlinear pendulum controller whose mechanical design was based on parameters determined by means of a parametric study carried out with 2D and 3D mathematical models of the coupled pendulum-structure system. The effectiveness of the proposed solutions is evaluated in terms of the fatigue life of critical welded connections.

CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석 (Cavitation Analysis on Ship Seawater Pump Using CFD)

  • 김부기;김홍렬;양창조;김준호
    • 해양환경안전학회지
    • /
    • 제23권4호
    • /
    • pp.400-406
    • /
    • 2017
  • 선박용 입형 편흡입 원심 해수펌프의 회전체와 파이프 시스템 내부에 발생한 과도한 손상의 원인을 분석하고자 실제 모델을 역설계 하였다. 이를 위해 전산유체역학(CFD)을 이용하여 해수냉각펌프의 내부유동 분석을 실시하였다. 결과적으로 역설계를 통한 대상펌프의 형상 및 경계조건을 설정하여 설계 운전점인 $125m^3/h$에서의 펌프 효율은 85.3 %, 양정 32.0미터로 계산되었다. 대상 펌프의 최고 효율점은 $150m^3/h$에서 약 86.2 %로 예측되었으나 실제 운전점과는 차이가 있었다. 최저 유량점인 $112.5m^3/h$에서는 저 유량점 특성상 유동이 불안정하여 해석의 수렴이 좋지 않았다. 선박에서 운전 중인 해수펌프 및 파이프 시스템 전반에 걸쳐 진행 중인 공동현상의 원인 규명을 통해 개선방안을 도출하고자 하였으나, 입 출구 전체 파이프 시스템의 계산, 각 지관들에 대한 유량 및 유속 측정 등을 통해 보다 명확한 원인분석을 위한 후속연구가 필요하다.

선박용 U형 벨로우즈의 성능 향상을 위한 형상 최적화 (Shape Optimization for Performance Improvement of Ship's U-type Bellows)

  • 김형준;김현수;김종필;박준홍;윤명진
    • 한국해양공학회지
    • /
    • 제20권6호
    • /
    • pp.123-129
    • /
    • 2006
  • The mechanical properties of bellows, such as the extensibility and the strength can be changed depending on the shape. For the shipbuilding material, it is desirable that the fatigue life is long due to the elastic property and the reduction of thermal stress in piping system. Nowadays, the domestic production and design of bellows are based on the E.J.M.A. Code. Therefore, the design standard is in need because of much errors and lack of detailed analysis. In this study, it is attempted to find out the optimal shape of U-type bellows using the finite element analysis. The design factors, mountain height, length, thickness, and the number of convolutions are considered and the proper values are chosen for the simulation. The results shaw that as the number of convolutions reduces, the volume decreases while the stress increases. However, as the number of convolutions increases, the volume increases above the standard volume and the stress obviously increases. In addition, the effect of the thickness of bellows on the stress is very large. Both of the mass and stress are decreasing at a certain lower value region. Also, we investigated shape optimization with considering maximum stress distribution tendency.

수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구 (An experimental study on the operating performance of facade installed natural circulation type solar thermal system)

  • 백남춘;이왕제;이진국;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

일차 냉각계통 스트레이너에 대한 내진 건전성 평가 (Seismic Evaluation for Strainer in the Primary Cooling System)

  • 정철섭
    • 한국전산구조공학회논문집
    • /
    • 제13권3호
    • /
    • pp.295-304
    • /
    • 2000
  • 본 연구의 목적은 지진하중에 대한 응력 해석을 수행하여 ASME, Class 3 설계요건에 따라 스트레이너의 구조건진성을 평가하는 것이다. 스트레이너에 대한 설계요건이 ASME 코드 내에 명백하게 규정되어 있지 않기 때문에 본체는 밸브 설계요건인 ND-3500을 적용하고, 양쪽 플랜지 연결부는 배관 설계요건 중 ND-3658.3을 적용하였으며, 하단의 덮개 플랜지는 Appendix XI에 따라 설계 및 해석을 수행하였다. 본 연구에서는 T형 스트레이너를 쉘로 모델링하여 유한요소법을 사용하여 지진하중에 의해 스트레이너가 응답하는 모드 형상 및 고유진동수를 계산하여 충분히 강건한 구조물임을 입증한 후 정적 해석을 수행하여 주관과 분기 관이 접합하는 연결부위와 같은 위험단면에서의 막응력과 굽힘 응력을 구하였다. 각 하중조합에 대해 코드에서 규정하고있는 허용 값과 비교한 결과 스트레이너는 지진하중이 작용하는 경우 구조적 건전성을 유지하고 있음을 확인하였다. 아울러 인접 배관을 연결해주는 플랜지 연결부의 응력을 규정에 따라 구한 후 설계요건에 의한 허용 값과 비교하여 건전성을 만족함을 알 수 있었다.

  • PDF

분기관파단이 노심지지배럴의 쉘응답에 미치는 영향 (The Effect of Tributary Pipe Breaks on the Core Support Barrel Shell Responses)

  • Jhung, Myung-Jo;Hwan, Won-Gul
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.204-214
    • /
    • 1993
  • 본 논문은 원자력발전소의 배관설계에 파단전 누설(leak-before-break : LBB) 개념이 적용됨에 따라 새롭게 해석대상이 된 분기관파단에 의한 노심지지배럴의 쉘응답을 계산한 것이다. 앞으로 직경 10인치 이상의 고에너지 배관에 대해 LBB 개념이 적용될 것으로 예상되는 바, 이 경우 LBB 적용대상에서 제외되는 유일한 1차측 배관인 3인치 가압기 분무관의 파단을 가정하였고 이때 노심 지지배럴에 가해지는 쉘응답을 구하였다. 이들 응답을 직경 10인치 이상인 배관파단시의 응답과 비교한 결과 앞으로 직경 10인치 이상의 배관에 대해 LBB 개념이 적용될 경우 배관파단에 대한 노심지지배럴의 쉘응답은 무시할 수 있음을 보였다.

  • PDF

그루브 조인트가 설치된 수계소화설비 입상배관계통의 지진거동분석을 위한 실험적 연구 (Experimental Study for Seismic Behavior Analysis of a Fire Protection Riser Pipe System with Groove Joints)

  • 김성완;윤다운;김재봉;전법규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권2호
    • /
    • pp.35-42
    • /
    • 2021
  • 본 연구에서는 NFPA 13을 참조하여 구조물 2층을 구현한 강재지그를 제작하였으며, 그루브 조인트의 배관연결재가 적용된 배관계통을 구성하고 정적 반복가력에 의한 지진모사실험을 수행하였다. 지진모사실험은 엑츄에이터로 건축물 내진설계기준의 최대허용 층간변위에 대한 반복가력실험을 수행하였다. 지진하중 발생 시 입상배관의 구조물에 대한 변형 또는 구조부재간의 상대변위에 의한 변위지배적인 거동에 따른 배관계통과 주요 배관요소의 지진거동을 분석하였다. 배관계통의 변형각은 기존의 센서를 이용하여 측정하기가 어려우므로 이미지측정시스템을 적용하였다.

비 이상화된 원주방향 관통균열이 존재하는 두꺼운 배관의 균열 성장 매개변수 계산 (Evaluation of Crack Growth Estimation Parameters of Thick-Walled Cylinder with Non-Idealized Circumferential Through-Wall Cracks)

  • 한태송;허남수;박치용
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.138-146
    • /
    • 2013
  • 본 논문에서는 두꺼운 배관에 존재하는 비 이상화된 원주방향 관통균열의 탄성 응력확대계수 해를 제시하였다. 이를 위해 3차원 탄성 유한요소해석을 수행하였으며, 배관의 형상 및 비 이상화된 원주방향 관통균열의 영향을 고려하기 위해 배관의 두께, 기준균열길이 및 관통균열길이 비를 체계적으로 변화시켰다. 하중 조건으로는 인장하중, 굽힘모멘트 및 내압을 고려하였다. 또한 본 논문에서는 이상화된 원주방향 관통 균열로부터 비 이상화된 원주방향 관통균열의 응력확대계수를 쉽게 계산하기 위해 관통균열 보정계수를 제시하였다. 본 논문의 결과는 실제 균열성장거동을 고려하여 원자력 배관의 배관파단확률을 보다 정확하게 계산하기 위해 적용될 수 있다.