• Title/Summary/Keyword: Pipelines

Search Result 828, Processing Time 0.026 seconds

A review of recent research advances on structural health monitoring in Western Australia

  • Li, Jun;Hao, Hong
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.1
    • /
    • pp.33-49
    • /
    • 2016
  • Structural Health Monitoring (SHM) has been attracting numerous research efforts around the world because it targets at monitoring structural conditions and performance to prevent catastrophic failure, and to provide quantitative data for engineers and infrastructure owners to design a reliable and economical asset management strategy. In the past decade, with supports from Australian Research Council (ARC), Cooperative Research Center for Infrastructure and Engineering Asset Management (CIEAM), CSIRO and industry partners, intensive research works have been conducted in the School of Civil, Environmental and Mining Engineering, University of Western Australia and Centre for Infrastructural Monitoring and Protection, Curtin University on various techniques of SHM. The researches include the development of hardware, software and various algorithms, such as various signal processing techniques for operational modal analysis, modal analysis toolbox, non-model based methods for assessing the shear connection in composite bridges and identifying the free spanning and supports conditions of pipelines, vibration based structural damage identification and model updating approaches considering uncertainty and noise effects, structural identification under moving loads, guided wave propagation technique for detecting debonding damage, and relative displacement sensors for SHM in composite and steel truss bridges. This paper aims at summarizing and reviewing the recent research advances on SHM of civil infrastructure in Western Australia.

A Galvanic Sensor for Monitoring the External and Internal Corrosion Damage of Buried Pipelines

  • Choi, Yoon-Seok;Kim, Jung-Gu;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.4 no.5
    • /
    • pp.178-190
    • /
    • 2005
  • In order to develop a new corrosion sensor for detecting and monitoring the external and internal corrosion damage of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm) and synthetic tap water environments. In this paper, two types of galvanic probes were manufactured: copper-pipeline steel (Cu-CS) and stainless steel-pipeline steel (SS-CS). The corrosion behavior in synthetic groundwater and synthetic tap water for the different electrodes was investigated by potentiodynamic test. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. In the soil resistivity of $5,000{\Omega}-cm$ and tap water environments, only the Cu-CS probe had a good linear quantitative relationship between the sensor output current and the corrosion rate of pipeline steel. In the case of $10,000{\Omega}-cm$, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe due to the high current output.

Failure Behavior of T-joint Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 T-joint 배관의 파손거동)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.80-87
    • /
    • 2014
  • The pipelines are apt to erosion or corrosion because of the high-speed flow of water and steam with high temperatures or high pressures. This study was carried out a finite element analysis (FEA) and an experimental for the fracture behavior of T-joint pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion and corrosion of the metal. The configurations of the eroded area included an eroded ratio of d/t=0.80~0.963 and an eroded length of l=25 mm, 50 mm, and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using FEA, which accurately simulates failure behaviors. In regards to the relationship between pressure and eroded, the criterion that indicates what can be used safely under operating pressure and design pressure were obtained from FEA. The FEA results were in relatively good agreement with that of the experiment.

Sludge Detection Inside Pipes Using Torsional Guided Waves (비틀림 유도파를 이용한 배관 내부 슬러지검출)

  • Park, Kyung-Jo;Kim, Chung-Yup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.282-290
    • /
    • 2013
  • A new method is presented that uses guided wave techniques for sludge and blockages detection in long-range pipelines. Existing techniques have the limitations that the sludge position needs to be known a priori and the area to be inspected needs to be accessible. Two guided wave techniques have been developed which allow the sludge or blockages to be detected remotely without the need to access the specific location where the pipe is blocked, nor to open the pipe. The first technique measures the reflection of guided waves by sludge which can be used to accurately locate the blocked region; the second technique detects sludge by revealing the changes to the transmitted guided waves propagating in the blocked region or after it. The two techniques complement each other and their combination leads to a reliable sludge or blockage detection. Various types of realistic sludge have been considered in the study and the practical capabilities of the two techniques have been demonstrated.

Numerical Prediction of the Outer Diameter for SAW Pipes Formed by Press-Brake Bending (프레스-브레이킹 굽힘 공정을 이용한 SAW 후육강관의 외경 예측을 위한 해석적 연구)

  • Park, G.B.;Kang, B.K.;Kang, B.S.;Ku, T.W.
    • Transactions of Materials Processing
    • /
    • v.25 no.2
    • /
    • pp.116-123
    • /
    • 2016
  • Press-brake bending is used to shape flat and thick plates into a targeted circular configuration without excessive localized thinning or thickening. A brake bending press called 'a knife press bending apparatus' has been widely adopted to manufacture thick, large and long pipe from initially thick plate. Submerged Arc Welded (SAW) pipes are also produced by employing press-brake bending. These pipes are mainly used for oil, natural gas and water pipelines. The principal process variables for press-brake bending can be summarized as stroke of the press-brake knife, the distance between both roll in the lower die, and the feeding length of the plate. Many combinations of these process variables are available, thus various pipe diameters can be realized. In the current study, a series of repetitive numerical simulations by feeding a thick plate with initial thickness of 25.4mm were conducted with the consideration of elastic recovery. Furthermore, an index for SAW pipe production is proposed which can be widely used in industry.

An Experimental Study on Root-pass Welding of Open Gap by GMA Welding Process in Pipeline (GMA 용접공정을 이용한 오픈갭 수평고정관 초층 용접의 실험적 연구)

  • Kim, Ji-Sun;Kim, Ill-Soo;Park, Chang-Eun;Na, Hyun-Ho;Lee, Ji-Hye;Jung, Seong-Myeong
    • Journal of Welding and Joining
    • /
    • v.29 no.3
    • /
    • pp.64-69
    • /
    • 2011
  • Since welding process for most pipelines with large diameter has been carried out by the manual process, automation of the welding process is necessary for the sake of consistent weld quality and improvement in productivity. Therefore the development of the optimized algorithm to decide the welding condition is an effective technique to prove the feasibility of interface standards and intelligent control technology to increase productivity and reduce the cost of system integration. In this study, the pipe welding experiment has been carried out using plused GMA welding process to select optimal welding condition. And necessary information in root-pass welding has been obtained by applying in the pipeline using the selected welding conditions through the welding experiment.

Whole genome sequencing of foot-and-mouth disease virus using benchtop next generation sequencing (NGS) system

  • Moon, Sung-Hyun;Oh, Yeonsu;Tark, Dongseob;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.4
    • /
    • pp.297-300
    • /
    • 2019
  • In countries with FMD vaccination, as in Korea, typical clinical signs do not appear, and even in FMD positive cases, it is difficult to isolate the FMDV or obtain whole genome sequence. To overcome this problem, more rapid and simple NGS system is required to control FMD in Korea. FMDV (O/Boeun/ SKR/2017) RNA was extracted and sequenced using Ion Torrent's bench-top sequencer with amplicon panel with optimized bioinformatics pipelines. The whole genome sequencing of raw data generated data of 1,839,864 (mean read length 283 bp) reads comprising a total of 521,641,058 (≥Q20 475,327,721). Compared with FMDV (GenBank accession No. MG983730), the FMDV sequences in this study showed 99.83% nucleotide identity. Further study is needed to identify these differences. In this study, fast and robust methods for benchtop next generation sequencing (NGS) system was developed for analysis of Foot-and-mouth disease virus (FMDV) whole genome sequences.

The Usability of Zinc Electrode using Wireless Measuring System of Electric Potential (무선전위측정시스템에 사용하는 아연전극 활용성 검토)

  • Lee, Jong-Rark;Leem, Sa-Hawn;Kim, Sang-O
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.177-180
    • /
    • 2006
  • This study is to make a basic study if solid zinc (Zn) can be used for buried reference electrode, so we examined the adequacy of zinc as reference electrode by using zinc which showed regular electrode for buried period. The deference of electric potential if zinc electrode for corrosion factor such as soil resistivity or pH didn't show fixed trend and there was no clear trend on the change of measurement period. From field test, it is known that the natural electric potential difference of CSE electrode and zinc electrode is 1,100mV, but the electric potential of zinc electrode for CSE electrode in the natural soil and copying soil was 1,094~1,158mV. There was no fixed trend on the change of measurement period and electric potential difference of zinc electrode for corrosion factors such as soil resistivity or pH. Consequently, there was 40~60mV of electric potential difference in every copying soil during the experiment measurement.

  • PDF

Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank (LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석)

  • 신은철;오영인;이상혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

Damage Estimation Based on Spatial Variability of Seismic Parameters Using GIS Kriging (GIS Kriging을 이용하여 공간적으로 분포하는 지진매개변수의 분석과 손상 평가)

  • Jeon Sang-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.33-44
    • /
    • 2004
  • This paper is focused on the spatial variability of measured strong motion data during earthquake and its relationship with the performance of water distribution pipelines and residential buildings. Analyses of strong motion and the correlations of peak ground velocity (PGV) and pipeline and building damage were conducted with a very large geographical information system (GIS) database including the relationship of time and earthquake intensity and the measured location, and Kriging spatial statistics. Kriging was used to develop regressions of pipeline repair rate (RR) and residential building damage ratio (DR) associated with $90\%$ confidence peak ground velocity (PGV). Such regressions using Kriging provide an explicit means of characterizing the uncertainty embodied in the strong motion data compared with other spacial statistics such as inverse distance method.