• Title/Summary/Keyword: Pipeline Network

Search Result 198, Processing Time 0.032 seconds

A Study on Improving HTTP latency for the Latency Web Document Processing (효율적인 웹문서 처리를 위한 HTTP 지연 개선에 관한 연구)

  • 고일석;최우진;나윤지;류승렬
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.2
    • /
    • pp.47-52
    • /
    • 2002
  • Recently, network overload is greatly increased with explosive use of internet. So the Hyper-Text Transfer Protocol(HTTP) is required improve of performance for decreasing of latency on the web document processing. The P-HTTP is one of the improved mood of He HTTP and has pipeline structure, but performance of the P-HTTP is decreased on interaction between the TCP and P-HTTP. Modification of structural design of the HTTP is not enough to improvement this problem. In this paper, we analyse performance of the HTTP and P-HTTP, and propose a new method on improving HTTP latency for the efficient web document processing.

  • PDF

ICS Security Risk Analysis Using Attack Tree (공격 트리를 이용한 산업 제어 시스템 보안 위험 분석)

  • Kim, Kyung-Ah;Lee, Dae-Sung;Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.11 no.6
    • /
    • pp.53-58
    • /
    • 2011
  • There is increasing use of common commercial operation system and standard PCs to control industrial production systems, and cyber security threat for industrial facilities have emerged as a serious problem. Now these network connected ICS(Industrial Control Systems) stand vulnerable to the same threats that the enterprise information systems have faced and they are exposed to malicious attacks. In particular Stuxnet is a computer worm targeting a specific industrial control system, such as a gas pipeline or power plant and in theory, being able to cause physical damage. In this paper we present an overview of the general configuration and cyber security threats of a SCADA and investigate the attack tree analysis to identify and assess security vulnerabilities in SCADA for the purpose of response to cyber attacks in advance.

Diagnosis of Cryogenic Pump-Motor Systems Using Vibration and Current Signature Analysis

  • Choi Byeong-Keun;Kim Hak-Eun;Gu Dong-Sik;Kim Hyo-Jung;Jeong Han-Eul
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.972-980
    • /
    • 2006
  • In general, to send out natural gas via a pipeline network across the nation in LNG terminal, high-pressure cryogenic pump supply highly compressed LNG to high-pressure vaporization facilities. The Number of cryogenic pumps determined the send-out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high vibration at cryogenic pumps-motor system in LNG terminal, vibration spectrum analysis and motor current signature analysis have been performed together. Through the analysis, motor rotor bar problems are estimated by the vibration analysis and confirmed by the current analysis. So, it is demonstrated through the case study in this paper, how performing vibration analysis and current signature analysis together can reliable diagnosis rotor bar problems in pump-motor system.

Cavitation Condition Monitoring of Butterfly Valve Using Support Vector Machine (SVM을 이용한 버터플라이 밸브의 캐비테이션 상태감시)

  • 황원우;고명환;양보석
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.119-127
    • /
    • 2004
  • Butterfly valves are popularly used in service in the industrial and water works pipeline systems with large diameter because of its lightweight, simple structure and the rapidity of its manipulation. Sometimes cavitation can occur. resulting in noise, vibration and rapid deterioration of the valve trim, and do not allow further operation. Thus, the monitoring of cavitation is of economic interest and is very importance in industry. This paper proposes a condition monitoring scheme using statistical feature evaluation and support vector machine (SVM) to detect the cavitation conditions of butterfly valve which used as a flow control valve at the pumping stations. The stationary features of vibration signals are extracted from statistical moments. The SVMs are trained, and then classify normal and cavitation conditions of control valves. The SVMs with the reorganized feature vectors can distinguish the class of the untrained and untested data. The classification validity of this method is examined by various signals that are acquired from butterfly valves in the pumping stations and compared the classification success rate with those of self-organizing feature map neural network.

A 10-bit 100Msample/s Pipeline ADC with 70dBc SFDR (SFDR 70dBc의 성능을 제공하는 10비트 100MS/s 파이프라인 ADC 설계)

  • Yeo, Seon-Mi;Moon, Young-Joo;Park, Kyong-Tae;Roh, Hyoung-Hwan;Park, Jun-Seok;Oh, Ha-Ryoung;Seong, Yeong-Rak;Jung, Myeong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1444-1445
    • /
    • 2008
  • 최근 Wireless Local Area Network(WLAN), Wide-band Code Division Multiple Access(WCDMA), CDMA2000, Bluetooth 등 다양한 모바일 통신 시스템에 대한 수요가 증가하고 있다. 이와 같은 모바일 통신 시스템에는 70dB이상의 SFDR(Spurious Free Dynamic Range)을 가진 ADC(Analog-to-Digital Converter)가 사용된다. 본 논문에서는 모바일 통신 시스템을 위한 SFDR 70dBc의 성능을 제공하는 10비트, 100Msps 파이프라인 ADC를 제안한다. 제안한 ADC는 요구되는 해상도 및 속도 사양을 만족시키기 위해 3단 파이프라인 구조를 채택하였으며, 입력단 SHA(Sample and Hold)회로에는 Nyquist 입력에서도 10비트 이상의 정확도로 신호를 샘플링하기 위해 부트스트래핑 기법 기반의 샘플링 스위치를 적용하였다. residue amplifier 회로에는 전력을 줄이기 위해 8배 residue amplifier 대신 3개의 2배 ressidue amplifier를 사용하였다. ADC의 높은 사양을 만족시키기 위해서는 높은 이득을 가지는 op-amp가 필수적이다. 제안한 ADC 는 0.18um CMOS 공정으로 설계되었으며, 100Msps의 동작 속도에서 70dBc 수준의 SFDR과 60dB 수준의 SNDR(Signal to Noise and Distortion Ratio)을 보여준다.

  • PDF

Evaluation of Risk Factors in Water Supply Networks using PROMETHEE and ANP (PROMETHEE와 ANP 기법을 활용한 상수도관망의 위험요소 평가)

  • Hong, Sung-Jun;Lee, Yong-Dae;Kim, Sheung-Kown;Kim, Joong-Hoon
    • IE interfaces
    • /
    • v.19 no.2
    • /
    • pp.106-116
    • /
    • 2006
  • In this study, the priority of risk factors in supplying water through water supply pipeline network was evaluated by PROMETHEE and ANP multi-criteria decision analysis. We chose 'corrosion', 'burst' and 'water pollution' in pipe as major reference criteria and selected eight risk factors to evaluate the priority, and then we compared the results of PROMETHEE with those of ANP. We also analyzed the results of the sensitivity analysis by changing the weights and parameters of preference functions in PROMETHEE. We investigated the possibility of integrating two methods by using the results of ANP as the weights of preference function in PROMETHEE. The priority of risk factors for supplying municipal water which is evaluated by this study may provide basic data to establish a contingency plan for accidents, or to establish the specific emergency response procedures.

A Proposal of Distribution Method for Inter-Regional Sewage Treatement Zone Using GIS and Gravity Model (GIS와 중력모형을 이용한 광역 하수처리권역 설정)

  • 하성룡;박대희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 1998.11a
    • /
    • pp.20-25
    • /
    • 1998
  • In order to support effective decision-making related to inter-sewage planning, this study proposes the spatial distribution method of inter-sewage treatement area using spatial analysis of GIS, Communication system of database, spatial interaction of Gravity model. Evalution Indexs are consist of economic, social/political and environmental condition value which are explained by the analysis of AHP algorithm ,based on opinion of related experts. Network module in Arc/Info is applied in order to find out minimum pipeline root in Miho river watershed, one of the sub-basin of Geum river basin. This value also is utilized for the construction of cost decay function in gravity model.

  • PDF

Benefits of procyanidins on gut microbiota in Bama minipigs and implications in replacing antibiotics

  • Zhao, Tingting;Shen, Xiaojuan;Dai, Chang;Cui, Li
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.798-807
    • /
    • 2018
  • Several studies have reported the effect of absorption of procyanidins and their contribution to the small intestine. However, differences between dietary interventions of procyanidins and interventions via antibiotic feeding in pigs are rarely reported. Following 16S rRNA gene Illumina MiSeq sequencing, we observed that both procyanidin administration for 2 months (procyanidin-1 group) and continuous antibiotic feeding for 1 month followed by procyanidin for 1 month (procyanidin-2 group) increased the number of operational taxonomic units, as well as the Chao 1 and ACE indices, compared to those in pigs undergoing antibiotic administration for 2 months (antibiotic group). The genera Fibrobacter and Spirochaete were more abundant in the antibiotic group than in the procyanidin-1 and procyanidin-2 groups. Principal component analysis revealed clear separations among the three groups. Additionally, using the online Molecular Ecological Network Analyses pipeline, three co-occurrence networks were constructed; Lactobacillus was in a co-occurrence relationship with Trichococcus and Desulfovibrio and a co-exclusion relationship with Bacillus and Spharerochaeta. Furthermore, metabolic function analysis by phylogenetic investigation of communities by reconstruction of unobserved states demonstrated modulation of pathways involved in the metabolism of carbohydrates, amino acids, energy, and nucleotides. These data suggest that procyanidin influences the gut microbiota and the intestinal metabolic function to produce beneficial effects on metabolic homeostasis.

Development of monitoring and control facilities with data logging and automatic recovery capabilities (데이터 로깅 및 자동 복구 기능을 갖춘 감시제어설비 모듈 개발)

  • Bae, Jae-hwan;Park, Sang-chul;Baek, Dong-geun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.310-313
    • /
    • 2022
  • In the pipeline for supplying purified water to each household, measurements such as flow meters and pressure meters are installed at important points to monitor in real time. The measured data acquired to the central control room through wireless or wired communication, but data may not be acquired due to intermittent communication failures. Since then, even if the communication network is restored, data during the failure period is not stored on the site, or even if it is stored, data cannot be automatically stored in the database. Low cost with universally installed in the field in order to address these data logging by developing a module is compatible with PLC, automatically would like to make sure that we can recover in the database.

  • PDF

Implementation of RTD-2000 Based Waterworks Pipe Network Monitoring System using Internet Map Service (범용지도를 이용한 RTD-2000 기반의 상수도 관망 모니터링 시스템의 구현)

  • Park, Jun-Tae;Hong, In-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.11
    • /
    • pp.1450-1457
    • /
    • 2011
  • Currently most of leak detection monitoring systems use digital maps with paying royalties, and this increases the cost of system construction and financial burdens on local self-governing bodies that manage such systems. Moreover, they have inefficiencies in repair and maintenance, functional expansion, and compatibility with other systems. Thus, this study developed a waterworks pipe network monitoring system that pursues low cost and high efficiency using general-purpose maps on the Internet such as google maps. As this system uses highly compatible free maps, it costs less in construction and its hardware requirements are lower than existing systems, and consequently, overall monitoring performance is enhanced and the cost of construction goes down sharply. This study also proposed a method for pipeline DB construction, which can be started together with the construction of the monitoring system, in order to improve the field applicability of the system.