• Title/Summary/Keyword: Pinch power

Search Result 67, Processing Time 0.029 seconds

Simulation of 4H-SiC MESFET for High Power and High Frequency Response

  • Chattopadhyay, S.N.;Pandey, P.;Overton, C.B.;Krishnamoorthy, S.;Leong, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.3
    • /
    • pp.251-263
    • /
    • 2008
  • In this paper, we report an analytical modeling and 2-D Synopsys Sentaurus TCAD simulation of ion implanted silicon carbide MESFETs. The model has been developed to obtain the threshold voltage, drain-source current, intrinsic parameters such as, gate capacitance, drain-source resistance and transconductance considering different fabrication parameters such as ion dose, ion energy, ion range and annealing effect parameters. The model is useful in determining the ion implantation fabrication parameters from the optimization of the active implanted channel thickness for different ion doses resulting in the desired pinch off voltage needed for high drain current and high breakdown voltage. The drain current of approximately 10 A obtained from the analytical model agrees well with that of the Synopsys Sentaurus TCAD simulation and the breakdown voltage approximately 85 V obtained from the TCAD simulation agrees well with published experimental results. The gate-to-source capacitance and gate-to-drain capacitance, drain-source resistance and trans-conductance were studied to understand the device frequency response. Cut off and maximum frequencies of approximately 10 GHz and 29 GHz respectively were obtained from Sentaurus TCAD and verified by the Smith's chart.

Performance analysis of an organic Rankine cycle for ocean thermal energy conversion system according to the working fluid and the cycle (작동유체 및 사이클에 따른 해양온도차발전용 유기랭킨사이클의 성능분석)

  • Kim, Jun-Seong;Kim, Do-Yeop;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.881-889
    • /
    • 2015
  • Ocean thermal energy conversion is an organic Rankine cycle that generates power using the temperature difference between surface water and deep water. This study analyzes the thermodynamic efficiency of the cycle, which strongly depends on the working fluid and the cycle configuration. Cycles studied included the classical simple Rankine cycle, Rankine cycles with an open feedwater heater and an integrated regenerator, as well as the Kalina cycle. Nine kinds of simple refrigerants and three kinds of mixed refrigerants were investigated as the working fluids in this study. Pinch-point analysis that set a constant pinch-point temperature difference was applied in the performance analysis of the cycle. Results showed that thermodynamic efficiency was best when RE245fa2 was used as the working fluid with the simple Rankine cycle, the Rankine cycles with an open feedwater heater and an integrated regenerator, and when the mixing ratio of $NH_3/H_2O$ was 0.9:0.1 in the Kalina cycle. If the Rankine cycles with an open feedwater heater, an integrated regenerator, and the Kalina cycle were used for ocean thermal energy conversion, efficiency increases could be expected to be approximately 2.0%, 1.0%, and 10.0%, respectively, compared to the simple Rankine cycle.

Staged Reconstruction of the Mangled Hand with the Combined Use of Pedicled Groin Flap and Free Wrap Around Flap (광범위 수부 손상에서 서혜부 유경피판과 유리 포장주위피판을 이용한 단계적 무지 재건술)

  • Roh, Young-Hak;Chung, Moon-Sang;Baek, Goo-Hyun;Lee, Young-Ho;Gong, Hyun-Sik;Rhee, Seung-Hwan;Lee, Ye-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • Purpose: Despite the free tissue transfer using microsurgical technique being the current trend of soft tissue reconstruction of the hand, the pedicled groin flap has the advantage to provide coverage for the mangled hand without necessitating the use of a damaged arterial system and also providing the benefit of saving the arterial system for later free tissue transfer. This report presents the author's experience using pedicled groin flap in four cases of mangled hands with massive bone and soft tissue defects requiring later thumb reconstruction with the free wrap around flap. Materials and methods: The patients' age ranged from 30 to 51 years; three patients were male and one was female. The causes of mangled hand included two machinery crush injuries, one laboratory explosion and one motor vehicle accident. While evaluating the post-operative results, factors like flap survival, complications, stability in opposition, pinch power and 2 point discrimination were taken into account. Results: All massive soft tissue defects of the hands were completely covered with pedicled groin flap successfully. The reconstructed thumb using free wrap around flap did not have any limitation in opposition. There was no occurrence of post-operative infection and all the flaps survived completely. The average pinch power was 70% of the contralateral intact thumb and average 2 point discrimination was 10 mm. Conclusion: The pedicled groin flap for the reconstruction of the massive soft tissue defects of the hand with subsequent reconstruction of the thumb with a wrap around flap is a very useful procedure. The combined use of pedicled groin flap and wrap around flap allows adequate coverage of sizable soft tissue defects and functional thumb opposition in cases of reconstruction of the mangled hands.

  • PDF

The Study of Verification Bi-Digital O-Ring Test by gauges (계측기(計測器)를 이용한 O-Ring Test법(法)의 검증(檢證)에 관(關)한 연구(硏究))

  • Kim, Jeong-Ryeol;Kim, Dal-Rae
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.225-247
    • /
    • 1995
  • Using Bi-Digital O-Ring Test which was developed by Ohmura Toshiaki, constiution classification by the vegetables' was Measured by various muscle power measurement meters and the results are as follow: 1. Pinch Gauge (Model:pc5030HPG, Japan) is the gauge to measure finger power between the thumb and the second finger, Grip Strength Dynamometer (Model: T.K.K. 5101, Japan) is to measure the hand power (hand dynamometer), Back Strength Dynamometer (Model: T.K.K. 5102, Japan) is to measure back muscle strength, Vertical jump Meter (Model: T.K.K. 5106, Japan) is to measure the height of jump. The above gauges were and its result found that the radish, potato, carrot and cucumber can influence to muscle strength was not true. 2. When the physical constitution is distinguished by the O-Ring Test method, Taeyangin's rate appeared as average 21% although it was insisted that there will be only 0.03-0.1%. This means that the physical constitution but it appears accidently according to the examinee's emotion about the material such as vegetable etc. as favor or unfavor. 3. It was found that the result of O-Ring Test is the same at any time and at any place was not true. there is no reemergence character. 4. The import of O-Ring Test mehtod to the physical discrimination disregarded that the mental factor influences absolutely to the physical heath in the ideological physi cal constitution medical science. 5. 'O-Ring Test method is a objective judgement method.' is wrong judgement. As you see on the above result, Bi-Digital O-Ring Test set the changeable voluntary muscle as the standard of the judgument, that was first mistake logically, second in spite of leass influence of mental influence by the examiner and examinee than the vegetable discrimination influence, the test disregarded the influence. Third, only grasp of some material on hand can influence to the voluntary muscle was a wrong theory disregarding the physiology. Finally the misunderstaning his subjective view as an objective view in spite of examiner and examinee's strong influence. Therefore such kind of physical descrimination method must be sublated.

  • PDF

Management of Failed Thumb Replantation (Early Soft Tissue Removal with Vascularized Flap Coverage of Amputated Phalangeal Bone) (무지 재접합 실패예에 대한 조기 치료로서 절단부의 수지골과 유리 피판술을 이용한 무지의 재건)

  • Chung, Duke-Whan;Kim, Ki-Bong
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.86-92
    • /
    • 2001
  • Failure of replantation is inevitable in finger replantation surgery, around 10% of failure rate are reported in many authors. Management of the failed finger replantation is one of big dilemma to microsurgeons. We report 5 cases of thumb reconstruction after failure of replantation. The reconstructive surgery composed with early debridement of soft tissue that are under gangrenous processing, extract the phalangeal bone without any soft tissues. Osteosynthesis of the extracted phalangeal bone with host phalangeal bone. The exposed bony portion covered with vascularized flaps such as revered radial forearm pedicled flap, free radial forearm flap and neurovascular island finger flap. This procedure underwent within a week after vascular insufficiency developed. All of the flaps are survived, bone union achieved within 3 months. The function and external appearance of the reconstructed thumb were encouraging; Pinch Power was average 1.2 Pounds. Early removal of necrotizing soft tissue followed by covering none vascular phalangeal bone which extracted from the dead phalanx with vascularized flap is one of the useful alterative solutions in failed replantation surgery in hand.

  • PDF

Salvage of Failed Digital Replantation Using Necrotizing Phalangeal Bone and Flap Coverage (수지 재접합 실패시 허혈 상태의 수지골과 피판술을 이용한 구제술)

  • Kwon, Boo-Kyung;Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.86-92
    • /
    • 2007
  • Failure of reattachment of finger is inevitable in replantation surgery and that failure rate is about 10 % are reported in many authors. Management of the failed finger replantation is challenge to microsurgeons. We report 7 cases of thumb reconstruction after failure of replantation. The reconstructive surgery composed with early debridement of soft tissue that are under gangrenous processing, extract the phalangeal bone without any soft tissues. Osteosynthesis of the extracted phalangeal bone with host phalangeal bone. The exposed bony portion covered with vascularized flaps such as reverse radial forearm pedicled flap, free radial forearm flap and neurovascular island finger flap. This procedure underwent within a week after vascular insufficiency developed. All of the flaps are survived, bone union achieved within 3 months. The function and external appearance of the reconstructed thumb were encouraging; pinch power was average 1.2 pounds. Early removal of necrotizing soft tissue followed by covering none vascular phalangeal bone which extracted from the dead phalanx with vascularized flap is one of the useful alterative solutions in failed replantation surgery in hand.

  • PDF

Design of Broadband 12 ㎓ Active Frequency Doubler using PHEMT (PHEMT를 이용한 광대역 12 ㎓ 능동 주파수 체배기 설계)

  • 전종환;강성민;최재홍;구경헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.6
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, active frequency doubler with broadband characteristics from 6 ㎓ to 12 ㎓ was designed and fabricated using PHEMT. The designed frequency multiplier has a bias point near pinch-off and a proposed series RC circuit between bias line and input matching network far the improvement of stability. With 0 ㏈m input power, second harmonic of 1.7 ㏈m at 12 ㎓ -27.5 ㏈c suppression of 6 ㎓ fundamental, -18 ㏈c suppression of 18 ㎓ 3rd harmonic, and the 3 ㏈ output bandwidth of 1,8 ㎓ have been measured.

High Voltage β-Ga2O3 Power Metal-Oxide-Semiconductor Field-Effect Transistors (고전압 β-산화갈륨(β-Ga2O3) 전력 MOSFETs)

  • Mun, Jae-Kyoung;Cho, Kyujun;Chang, Woojin;Lee, Hyungseok;Bae, Sungbum;Kim, Jeongjin;Sung, Hokun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • This report constitutes the first demonstration in Korea of single-crystal lateral gallium oxide ($Ga_2O_3$) as a metal-oxide-semiconductor field-effect-transistor (MOSFET), with a breakdown voltage in excess of 480 V. A Si-doped channel layer was grown on a Fe-doped semi-insulating ${\beta}-Ga_2O_3$ (010) substrate by molecular beam epitaxy. The single-crystal substrate was grown by the edge-defined film-fed growth method and wafered to a size of $10{\times}15mm^2$. Although we fabricated several types of power devices using the same process, we only report the characterization of a finger-type MOSFET with a gate length ($L_g$) of $2{\mu}m$ and a gate-drain spacing ($L_{gd}$) of $5{\mu}m$. The MOSFET showed a favorable drain current modulation according to the gate voltage swing. A complete drain current pinch-off feature was also obtained for $V_{gs}<-6V$, and the three-terminal off-state breakdown voltage was over 482 V in a $L_{gd}=5{\mu}m$ device measured in Fluorinert ambient at $V_{gs}=-10V$. A low drain leakage current of 4.7 nA at the off-state led to a high on/off drain current ratio of approximately $5.3{\times}10^5$. These device characteristics indicate the promising potential of $Ga_2O_3$-based electrical devices for next-generation high-power device applications, such as electrical autonomous vehicles, railroads, photovoltaics, renewable energy, and industry.

Characteristics of MHEMT Devices Having T-Shaped Gate Structure for W-Band MMIC (W-Band MMIC를 위한 T-형태 게이트 구조를 갖는 MHMET 소자 특성)

  • Lee, Jong-Min;Min, Byoung-Gue;Chang, Sung-Jae;Chang, Woo-Jin;Yoon, Hyung Sup;Jung, Hyun-Wook;Kim, Seong-Il;Kang, Dong Min;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, we fabricated a metamorphic high-electron-mobility transistor (mHEMT) device with a T-type gate structure for the implementation of W-band monolithic microwave integrated circuits (MMICs) and investigated its characteristics. To fabricate the mHEMT device, a recess process for etching of its Schottky layer was applied before gate metal deposition, and an e-beam lithography using a triple photoresist film for the T-gate structure was employed. We measured DC and RF characteristics of the fabricated device to verify the characteristics that can be used in W-band MMIC design. The mHEMT device exhibited DC characteristics such as a drain current density of 747 mA/mm, maximum transconductance of 1.354 S/mm, and pinch-off voltage of -0.42 V. Concerning the frequency characteristics, the device showed a cutoff frequency of 215 GHz and maximum oscillation frequency of 260 GHz, which provide sufficient performance for W-band MMIC design and fabrication. In addition, active and passive modeling was performed and its accuracy was evaluated by comparing the measured results. The developed mHEMT and device models could be used for the fabrication of W-band MMICs.

Groin flap and Neurovascular island flap for Reconstruction of the Thumb (서혜부 피판과 신경혈관 도서형 피판을 이용한 무지 재건술)

  • Jin, Jin-Woo;Kim, Chong-Kwan;Park, Chan-Wan;Lee, Young-Ho;Kwak, Wan-Sub;Jung, Sung-Weon
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.152-156
    • /
    • 2005
  • Purpose: We reconstructed the thumb with groin flap combined with secondary heterodigital neurovascular island flap and report our 6 cases. Materials and Methods: Between March 2003 and August 2004, 6 degloving thumbs or amputation of thumbs were reconstructed with groin flap combined with secondary heterodigital neurovascular island flap. There ware 4 men and 2 women, and mean age was 42.2 years. The following parameters were evaluated. Results: Recipient thumb was no limitation of apposition. but flexion contracture of interphalangeal joint was about 10 degree in two cases. Average grip power were 80% and average pinch power were 70% that of the normal thumb. The two point discrimination was average 10.5 mm and double sensibility in 2 cases. 2 patients have cold intolerance. Neuroma formation was not made. Cosmetic results as judged by patients were that 4 cases are good and 2 cases are fair. Conclusion: If massive skin defect after degloving thumb or amputation of thumb are present, we consider the numerous methods for reconstruction of thumb. This surgical procedure is good methods because of it's pliability, sensation, satisfactory functional results but major disadvantage are the staged operation and cosmetic effect of the absence of thumb nail.

  • PDF