• 제목/요약/키워드: Pinch power

검색결과 67건 처리시간 0.023초

흉곽출구증후군: 사각근 신장운동의 효과 (Thoracic Outlet Syndrome: The Effects of Scalenus Stretching Exercise)

  • 이문환
    • 한국전문물리치료학회지
    • /
    • 제13권2호
    • /
    • pp.43-51
    • /
    • 2006
  • The term thoracic outlet syndrome (TOS) is used to describe patients with compressed subclavian arteries, veins, and brachial plexuses in the region of the thoracic outlet. The objective of this study was to evaluate a scalenus stretching exercise that aims to restore normal function to patients with TOS. This study consisted of 60 patients with symptoms of TOS, and divided the patients into 3 groups: one that received manual therapy, one that practiced self stretching, and a control group. Each group consisted of 20 patients. This study assessed the efficacy of scalenus stretching exercise by examining the resting pain, tenderness, spherical grip power, and pinch grip power of patients. The data were analyzed using one-way ANOVA, Scheffe post hoc test, and independent t-test. The results showed that resting pain was statistically significant within the manual therapy and self stretching groups (p<.05), and that the resting pain of the manual therapy group was more statistically significant than that of the self stretching group (p<.05). Tenderness, spherical grip power, and pinch grip were statistically significant within the manual therapy and self stretching groups (p<.05), but there was no statistically significant difference between the two groups (p>.05). Finally I could see that there were no statistical differences between manual therapy and self stretching to improve the symptoms of the patients with TOS. These results imply that self stretching by patients is as important as manual therapy by a physical therapist.

  • PDF

핀치포인트온도차에 따른 해양온도차발전용 유기랭킨사이클의 성능분석 (Performance analysis of an organic Rankine cycle for ocean thermal energy conversion system according to pinch point temperature difference)

  • 김준성;김도엽;강호근;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.476-483
    • /
    • 2016
  • 해양온도차발전용 유기랭킨사이클은 해양의 표층수와 심층수사이의 온도차를 이용하여 발전하는 사이클이다. 작동유체는 유기랭킨사이클의 열역학적 성능에 있어 중요한 요소이다. 유기랭킨사이클의 열역학적 분석방법으로 핀치포인트분석이 있다. 본 연구는 열교환기내 핀치포인트온도차의 변화와 열원 및 열침의 출구온도의 변화에 따른 열역학적 성능분석을 수행하였다. 핀치포인트분석법에 따라 설계한 해양온도차발전용 단순랭킨사이클에 7종의 단일 작동유체를 적용하여 열역학적 성능을 분석하였다. 성능분석결과 열교환기에서 핀치포인트온도차와 열원 및 열침의 온도변화가 작을수록 사이클 총 비가역성 및 총 엑서지 파괴인자가 감소하였으며, 제2법칙 효율은 상승하였다. 또한 비가역성은 열역학적 변화가 발생한 곳에서 크게 변화하였다. RE245fa2는 선정한 작동유체 중에서 가장 우수한 열역학적 성능을 보여주었으며, 모든 작동유체의 성능은 유사하였다. 열교환기 및 작동유체 선정에 있어 열역학적 성능과 함께 다양한 요소들에 대해서도 엄밀한 이론적 근거가 필요하다.

자동차 전장에서 윈도우 모터 조립 부품의 생산 (Production of Window Motor Assembly Parts in Automotive Body)

  • 이정익
    • 한국융합학회논문지
    • /
    • 제3권4호
    • /
    • pp.29-34
    • /
    • 2012
  • 자동차는 2만 여개가 넘는 부품들로 구성되어 있다. 또한, 새시와 함께 자동차 내부에는 조향장치, 파워장치, 도어 록 장치 등 많은 전기 전자 및 센서들이 부가되어 수송 외 운전자가 주행 중 운전을 용이하게 수행할 수 있는 여러 가지 장치들이 별도로 차체내부 혹은 외부에 부착되어 있다. 그 가운데 자동차의 도어 유리 부위는 제작 초기에는 운전자가 직접 휠을 회전시켜 유리문을 상하로 개폐하였으나 최근 들어 모터, 센서, 스위치 류 등의 발달로 버튼하나로 문을 상하로 개폐시키는 방법을 사용하게 되었다. 유리문을 상하로 개폐시키는 조립부위를 자동차에서는 power window motor assembly라고 이를 개발하는 것이 본 연구의 목적이다. 현재는 anti-pinch type power window motor에 ECU(Electronic Control Unit) system이 국내에서 개발되지 못하고 있다. 뿐만 아니라, 이 연구에서는 CAE 해석과 개발을 통해 anti-pinch power motor gear housing 및 cylindrical gear를 국산화 개발하고 ECU 일체형 적용을 함으로 인해 조립공정의 단순화 및 원가절감에 기여하고자 한다.

Modified Materka Model를 이용한 4H-SiC MESFET 대신호 모델링 (4H-SiC MESFET Large Signal Modeling using Modified Materka Model)

  • 이수웅;송남진;범진욱
    • 한국전자파학회논문지
    • /
    • 제12권6호
    • /
    • pp.890-898
    • /
    • 2001
  • Modified Materka-Kacprzak 대신호 MESFET(Metal Semiconductor Field Effect Transistor) model을 사용하여 4H-SiC MESFET의 대신호 모델링을 수행하였다. Silvaco사의 소자 시뮬레이터인 ATLAS를 사용하여 4H-SiC MESFET 소자 시뮬레이션을 수행하고, 이 결과를 modified Materka 대신호 모델을 사용하여 모델링 하였다. 시뮬레이션 및 모델링 결과는 -8 V의 pinch off 전압과 $V_{GS}$ =0 V, $V_{DS}$ =25 V에서 $I_{DSS}$270 mA/mm, $G_{m}$ =52.8 ms/mm를 얻을 수 있었고, 전력 특성 시뮬레이션을 통해 2GHz, $V_{GS}$ =-4V, $V_{DS}$ =25 V에서 10dB의 Gain과 34dBm(1 dB compression point)의 출력전력, 7.6W/mm의 전력밀도, 37%의 PAE(power added efficiency)를 얻을 수 있었다.다.

  • PDF

전력소자 응용을 위한 4H-SiC MESFET 대신호 모텔링 (4H-SiC MESFET Large Signal modeling for Power device application)

  • 이수웅;송남진;범진욱;안철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.229-232
    • /
    • 2001
  • Modified Materka-Kacprzak 대신호 MESFET(Metal Semiconductor Field Effect Transistor) model을 사용하여 4H-SiC MESFET의 대신호 모델링을 수행하였다. Silvaco사의 소자 시뮬레이터인 ATLAS를 사용하여 4H-SiC MESFET 소자 시뮬레이션을 수행하고, 이 절과를 modified Materka 대신호 모델을 사용하여 모델링 하였다. 시뮬레이션 및 모델링 결과는 -8V의 pinch off 전압과 V/sub GS=0V, V/sub DS=25V에서 I/sub DSS=270㎃/㎜, G/sub m=45㎳/㎜를 얻을 수 있었고, 진력 특성 시뮬레이션을 통해 2㎓, V/sub GS=-4V, V/sub DS=25V에서 1()dB의 Gain과 34dBm(1dB compression point)의 출력전력, 7.6W/㎜의 전력밀도, 37%의 PAE(power added efficiency)를 얻을 수 있었다.

  • PDF

낮은 입력 정재파비와 잡음을 갖는 수동 및 능동 바이어스를 사용한 저잡음증폭기에 관한 연구 (LNA Design Uses Active and Passive Biasing Circuit to Achieve Simultaneous Low Input VSWR and Low Noise)

  • 전중성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1263-1268
    • /
    • 2008
  • In this paper, the low noise power amplifier for GaAs FET ATF-10136 is designed and fabricated with active bias circuit and self bias circuit. To supply most suitable voltage and current, active bias circuit is designed. Active biasing offers the advantage that variations in the pinch-off voltage($V_p$) and saturated drain current($I_{DSS}$) will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets a gate-source voltage($V_{gs}$) for the desired drain voltage and drain current. Using resistive decoupling circuits, a signal at low frequency is dissipated by a resistor. This design method increases the stability of the LNA, suitable for input stage matching and gate source bias. The LNA is fabricated on FR-4 substrate with active and self bias circuit, and integrated in aluminum housing. As a results, the characteristics of the active and self bias circuit LNA implemented more than 13 dB and 14 dB in gain, lower than 1 dB and 1.1 dB in noise figure, 1.7 and 1.8 input VSWR at normalized frequency $1.4{\sim}1.6$, respectively.

상완 신경총 손상시 건측 제 7번 경추신경 전이술 후 건측 상지의 신경 변화 (Neurologic Changes in the Donor Limb after Contralateral-C7 Transfer in Brachial Plexus Injury)

  • 한정수;차재룡;신동준;임양진
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권1호
    • /
    • pp.7-11
    • /
    • 2001
  • Purpose : To evaluate the neurologic abnormalities in the donor limb after contralateral C7 transfer in brachial plexus injury. Materials and Methods : From August 1996 to December 1999, five patients with brachial plexus injury were treated with contralateral C7 nerve root transfer. The average follow up was 16 months(range, 5 to 36 months). The clinical findings were assessed using the British Medical Research Council Grading System, and also measured grip power, pinch power of hand and two point discrimination of the fingers. Results : We had no difference in shoulder abduction and elbow flexion after contralateral C7 transfer. The grip and pinch strength were recovered within 4weeks. Sensory loss occurred in all patients and was noted to be more severe on index and middle finger. Four patients recovered within 2 weeks, one continued till one year. Subjective numbness and pain on percussion minimally persisted until last follow-up. Conclusion : The division of the C7 nerve root resulted in minimal and temporary functional deficit in the donor upper limb.

  • PDF

노인의 악력과 보행 가변성 간의 연관성: 예비연구 (Association between Hand Grip Strength and Gait Variability in Elderly: Pilot Study)

  • 이도연;이윤곤;신성훈
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.125-134
    • /
    • 2022
  • Purpose: The aim of this study was to establish an association between grip strength and gait variability in the elderly. Methods: The participants in this experiment (n = 20) were aged 65 or older. Power grip and lateral pinch forces were obtained in grip strength tests, and spatiotemporal gait parameters were collected from IMU sensors during 6 min actual walking to test the gait of participants. The collected gait parameters were converted to coefficient of variation (CV) values. To confirm the association between grip strength and gait variability, a partial correlation analysis was conducted in which height, weight, and gait speed were input as controlling variables. Results: Grip power showed a significant negative correlation with the stride length CV (r = -0.52), and the lateral pinch force showed a significant negative correlation with the stance CV (r = -0.65) and swing CV (r = -0.63). Conclusion: This study reveals that gait variability decreases as grip strength increases, although height, weight, and gait speed were controlled. Thus, grip strength testing, a simple aging evaluation method, can help identify unstable gait in older adults at risk of falling, and grip strength can be utilized as a non-invasive measurement method for frailty management and prevention.

Development of Pulsed Power System for 500kA Current Generation

  • Lee, Hyeong-Ho;Seo, Kil-Soo;Kim, Yeong-Bae;Cho, Kook-Hee
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.23-28
    • /
    • 1999
  • The manufactured pulsed power system with 500kA current is described in this paper. The capacitor bank, control cabinent, dec charging unit, closing switch and dumping box, cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch controlled by gas puffing enabled the generation of the very high voltage and current.

  • PDF

대전류 고속펄스파워시스템의 구성기술 (Composition Technology of Pulsed Power System with High Current)

  • 이형호;서길수;김영배;조국희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2179-2181
    • /
    • 1999
  • This paper describes the composition technology of pulsed power system with high current. The capacitor bank, control cabinet, dc charging unit, closing switch and cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch enabled the generation of the very high current.

  • PDF