• Title/Summary/Keyword: Pin-by-pin

Search Result 1,735, Processing Time 0.036 seconds

Long Bone Fractures in Raptors: 28 cases (2004-2007)

  • Yoon, Hun-Young;Fox, Derek B.;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.215-217
    • /
    • 2008
  • Medical records from the Veterinary Medical Teaching Hospital of the University of Missouri-Columbia from 2004 to 2007 were available for 28 raptors that underwent long bone fracture repair. There were 14 owls, 10 hawks, 2 vultures, 1 eagle, and 1 falcon. Mean body weight was 780 g (ranged from 150 to 1400 g) for 14 owls; 650 g (ranged from 150 to 1270 g) for 10 hawks; 1760 g (ranged from 1520 to 2000 g) for 2 vultures; 5000 g for 1 eagle; and 130 g for 1 falcon. Of all 28 fracture cases, 11 cases (39%) and 1 case (3%) were related to hit-by-car and shooting respectively. Physical examination revealed dehydration in 18 raptors (64%) and lethargy in 12 raptors (42%). Forty one long bone fractures were included in 28 cases. The radiographs revealed 13 ulnar fractures (32%), 12 humeral fractures (30%), 10 radial fractures (25%), 4 tibiotarsal fractures (9%), 1 femoral fracture (2%), and 1 fibular fracture (2%). External skeletal fixation using polymethylmethacrylate (PMMA) combined with intramedullary fixation was used in 19 long bone fractures (46%). Intramedullary fixation using intramedullary Kirschner pin was used in 16 long bone fractures (39%). No surgical treatment was performed in 6 long bone fractures (15%). This study reported that many of raptors presented dehydration and lethargy when admitted for treatment. Therefore, proper hydration and nutrition are critical pre-surgical requirements. In addition, combination of internal fixation and external skeletal fixation using PMMA might be better option to treat raptors with comminuted fracture that results from mostly trauma of hit-by-car.

Evaluation of The Moment Resistance of Reinforced Wooden Gusset to Glulam Joint (보강목질적층판이 사용된 집성재 접합부의 모멘트 저항성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-61
    • /
    • 2017
  • In this study, specimens were produced with a column member and a wooden gusset only by inserting an wooden gusset which is a substitute for steel plate into the center of a slit-processed column member. The moment resistance performance of the specimens was compared with that of control specimens that used a steel plate. The measured maximum moments of the specimens produced with GFRP-reinforced wooden laminated gussets and pins were lower by 24% on average compared to the steel plate-inserted specimens, but they showed good toughness. The fracture shape suggests that it was fractured along the annual rings between the pin and the end of the column member. The rigid specimen that integrated a laminated wood and a wooden laminated gusset with adhesive showed 2.8 times greater initial rigidity and 40% greater maximum moment on average compared to the control specimen. The rigid specimens mainly fractured on a glulam around glue line.

Design of High-Reliability Differential Paired eFuse OTP Memory for Power ICs (Power IC용 고신뢰성 Differential Paired eFuse OTP 메모리 설계)

  • Park, Young-Bae;Jin, Li-Yan;Choi, In-Hwa;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.405-413
    • /
    • 2013
  • In this paper, a high-reliability differential paired 24-bit eFuse OTP memory with program-verify-read mode for PMICs is designed. In the proposed program-verify-read mode, the eFuse OTP memory can do a sensing margin test with a variable pull-up load in consideration of programmed eFuse resistance variation and can output a comparison result through a PFb (pass fail bar) pin by comparing a programmed datum with its read one. It is verified by simulation results that the sensing resistance is lower with $4k{\Omega}$ in case of the designed differential paired eFuse OTP memory than $50k{\Omega}$ in case of its dual-port eFuse OTP memory.

A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle (하악 과두 골절의 개방 정복 시 근위 골편의 수복법)

  • Kim, Myung Good
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

Preparation and Quality Characterization of Garlic Gochujang with Alaska Pollock Therage chalcogramma Roe (명란 마늘 고추장의 제조 및 품질 특성)

  • Hwang, Ji-Young;Jeong, Hyo-Pin;Jang, Jong-Soo;Jang, Suck-Jun;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.235-242
    • /
    • 2017
  • This study was conducted to determine the optimum amount of dried Alaska Pollock Therage chalcogramma roe (D-AP-R) for preparing garlic gochujang with D-AP-R. We investigated the optimal preparation of garlic gochujang with D-AP-R by proximate composition, taste, color, and odor measurements and sensory evaluation. The moisture, ash contents and water activity of garlic gochujang with D-AP-R decreased as the amount of D-AP-R increased, whereas other components, such as crude protein and lipid contents, taste value, yellowness of Hunter color, and odor intensity, increased as D-AP-R increased. According to the sensory evaluation results, garlic gochujangs with 10 and 15% D-AP-R were superior to garlic gochujang without D-AP-R (control) in terms of taste and overall acceptance but inferior in terms of fish odor. However, there was no difference in the sensual color of garlic gochujang with versus without D-AP-R. These results suggest that high quality garlic gochujang can be prepared by adding 10% D-AP-R. The total amino acid content of garlic gochujang with 10% D-AP-R was 11.81 mg/100 g, which was higher than that of the control (9.05 mg/100 g). The cholesterol content of garlic gochujang with 10% D-AP-R was 16.1 mg/100 g, which is below the acceptable daily cholesterol intake (300 mg/day).

Development of LDV(Laser Doppler Velocimetry) for Measuring Three Dimensional Hull Wake of Ship Model in Large Cavitation Tunnel (대형 캐비테이션 터널 내 선박 모형의 3차원 선체 반류 계측을 위한 레이저 유속계 개발)

  • Paik, Bu-Geun;Ahn, Jong-Woo;Seol, Han-Shin;Park, Young-Ha;Kim, Ki-Sup;Cheon, Ho-Geun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.515-521
    • /
    • 2017
  • Large Cavitation Tunnel (LCT) of KRISO enables us to conduct cavitation tests of the propeller attached to a ship model. As the ship model tests are done at rather high Reynolds number of 107~108, flow measurement system such as pitot tube cannot be employed because of structural safety problems in its system and difficulties in installing it within the test section. Thus, KRISO has developed new 3-D LDV system used in large test section of LCT. There are several difficulties in using 3-D LDV, which did not allow efficient operation of it. The first trouble was the calibration using the conventional pin hole. To make the focus with same laser-beam waists at the wanted position, the high spatial resolution CCD is utilized in the calibration procedure for 3-D LDV. The off-axis configuration provides two velocity components in the horizontal plane and on-axis configuration gives third velocity component in the vertical plane. The horizontal velocity components are also obtained in the coincidence mode, which prevents any misleading results in the off-axis configuration. The nominal wake of Aframax tanker model is measured by the developed 3-D LDV system. The measured hull wake showed good agreement with that obtained by CFD calculation.

Preparation of Asymmetric Polyethersulfone Membrane and its Gas Separation Performance (폴리이서설폰 비대칭 기체분리막의 제조와 분리성능)

  • 함문기;손우익;이용택;김정훈;이수복
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.130-138
    • /
    • 2000
  • Polyethersulfone (PES) asymmetric membranes for gas separation were prepared by dry/wet phase inversion method and their separation properties for CO$_2$ and N$_2$ gases were investigated. The effects of important variables such as composition of casting solution and evaporation time in preparation of asymmetric gas membrane on membrane morphology and the separation properties were analyzed and the optimum condition of membrane preparation was established. To compensate the defects like pinholes existed on skin layer of the membrane prepared, the membranes were coated with silicone resin. By comparing separation properties after coating with those before coating, we found that the coating of silicone resin was effective to enhance the separation properties. The casting solution mainly used in this study consisted of PES, N-methyl-2-pyrrolidone, acetone, ethanol and distilled water was used as coagulation agent. It was shown that the selectivity for CO$_2$/N$_2$ was getting higher but the permeability decreases, as the contents of PES and volatile organic solvent and evaporation time increased. The selectivity for CO$_2$/N$_2$ and permeability of CO$_2$ of the membrane prepared under the optimum condition were found to be 61 and 21 GPU, respectively.

  • PDF

DIAGNOSTIC EFFICACY OF DITI (DIGITAL INFRARED THERMOGRAPHIC IMAGING) FOR THE DYSESTHESIA OF THE LOWER LIP & CHIN (하치조 신경손상에 따른 하순 및 이부의 지각이상시 적외선 체열검사(DITI)의 진단적 효용)

  • Kim, Yae-Won;Kim, Myung-Rae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.1
    • /
    • pp.53-60
    • /
    • 2002
  • Neurosensory dysfunction of the injured inferior alveolarnerve(IAN) is a common and distrssing consequence of traumatic or iatrogenic injury. Conventional neurosensory testing has been used to detect and monitor sensory impairments of the injured IAN. However, these tests had low reliability and are not qualitative at best because they are based on solely on the patient's subjective assesment of symptoms. Consequently, there is need for more reliable, sensitive, and objective test measures to document and to monitor sensory dysfunction of the trigeminal nerve. This study was to investigate DITI's (digital infrared thermographic imaging) potential as a diagnostic alternative for evaluating of the nerve injures and sensory disturbance. Subjects were 30 patients who had been referred to Ewha Medical Center due to sensory disturbance of the lower lip and chin followed after unobserved inferior alveolar nerve injuries. The patients were examined by clinical neurosensory tests as SLTD (static light touch discrimination), MDD (moving direction discrimination), PPN (pin prick nociception) and DITI (digital infrared thermographic imaging). The correlation between clinical sensory dysfunction scores(Sum of SLTD, MDD, PPN, NP, Tinel sign) and DITI were tested by Spearman nonparametric rank correlation anaylsis & Kruskal-Wallis test, Wilcoxon 2-sample test. This study resulted in as follows; (1) The difference of thermal difference between normal side and affected side was as ${\Delta}-3.2{\pm}0.13$. (2) The DITI differences of the subjects presenting dysesthesia of the lip and chin were correlated significantly with the neurosensory dysfunction scores(r=0.419, p=0.021)and SLTD (r=0.429, p<0.05). (3) The MDD, PPN, NP, Tinel sign, duration, gender were not correlated with DITI(p> 0.05). Therefore, the DITI(digital infrared thermographic imaging) can be an option of the useful objective diagnostic methods to evaluate the injured inferior alveolar nerve and sensory dysfunction of trigerminal nerve.

The Design of CMOS-based High Speed-Low Power BiCMOS LVDS Transmitter (CMOS공정 기반의 고속-저 전압 BiCMOS LVDS 구동기 설계)

  • Koo, Yong-Seo;Lee, Jae-Hyun
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.69-76
    • /
    • 2007
  • This paper presents the design of LVDS (Low-Voltage-Differential-Signaling) transmitter for Gb/s-per-pin operation. The proposed LVDS transmitter is designed using BiCMOS technology, which can be compatible with CMOS technology. To reduce chip area and enhance the robustness of LVDS transmitter, the MOS switches of transmitter are replaced with lateral bipolar transistor. The common emitter current gain($\beta$) of designed bipolar transistor is 20 and the cell size of LVDS transmitter is $0.01mm^2$. Also the proposed LVDS driver is operated at 1.8V and the maximum data rate is 2.8Gb/s approximately In addition, a novel ESD protection circuit is designed to protect the ESD phenomenon. This structure has low latch-up phenomenon by using turn on/off character of P-channel MOSFET and low triggering voltage by N-channel MOSFET in the SCR structure. The triggering voltage and holding voltage are simulated to 2.2V, 1.1V respectively.

  • PDF

Ankle Arthrodesis using Cannulated Screws & Hybrid Type Rigid External Fixation in Diabetic Charcot Neuroarthropathy (유관 나사 및 Hybrid형 외고정술을 이용한 당뇨병성 샤르코 족관절 신경관절병증의 관절 유합술)

  • Han, Kyeung-Jin;Roh, Hyong-Rae;Han, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.140-145
    • /
    • 2010
  • Purpose: The diabetic charcot neuroarthropathy of ankle is an infrequent site (around 5%), but is definitely the location that, because of the instability and progressive deformity it involves, cause ulceration in a high percentage of patients, and this can then become a reason for amputation. However, the treatment of this disastrous disease is still challenging. We analyzed the clinical and radiological results of ankle arthrodesis by our fixation method in Charcot neuroarthropathy. Materials and Methods: Seven cases that were diagnosed as charcot neuroarthropathy of ankle arthrodesis were followed for more than 16 months postoperatively. Mean age was 57 years, and the mean follow-up period was 27 months. Anterior approach was used in arthrodesis, and internal fixation by 3 or more cannulated screws and hybrid type external fixation were used. Auto iliac bone for grafting was combined in all cases. External fixator was kept for 3 months without weight-bearing. Then, boots brace was applied for more 3 months allowing partial weight-bearing. Four cases had minor complications such as pin site infection. Preoperative and postoperative AOFAS score, time to fusion and postoperative complications were checked. Results: Postoperative fusion was completed in all cases, and the mean time to fusion was 3.4 months. No postoperative complication was checked. At the last follow-up, the mean AOFAS score had increased from 54 points to 72 points. Patient's satisfaction was over 80%. Conclusion: Satisfactory results were obtained after ankle arthrodesis using internal and hybrid type external fixation combined with auto iliac bone graft in charcot neuroarthropathy with minor complications.