• Title/Summary/Keyword: Pin-by-pin

Search Result 1,735, Processing Time 0.03 seconds

The Design of High Speed Processor for a Sequence Logic Control using FPGA (FPGA를 이용한 시퀀스 로직 제어용 고속 프로세서 설계)

  • Yang, Oh
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1554-1563
    • /
    • 1999
  • This paper presents the design of high speed processor for a sequence logic control using field programmable gate array(FPGA). The sequence logic controller is widely used for automating a variety of industrial plants. The FPGA designed by VHDL consists of program and data memory interface block, input and output block, instruction fetch and decoder block, register and ALU block, program counter block, debug control block respectively. Dedicated clock inputs in the FPGA were used for high speed execution, and also the program memory was separated from the data memory for high speed execution of the sequence instructions at 40 MHz clock. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. In order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 16 bits or 32 bits respectively. And the real time debug operation was implemented for easy debugging the designed processor. This FPGA was synthesized by pASIC 2 SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to sequence control system with inputs and outputs of 256 points. The designed processor for the sequence logic was compared with the control system using the DSP(TM320C32-40MHz) and conventional PLC system. The designed processor for the sequence logic showed good performance.

  • PDF

Design of Vessel Assembly for Fuel Irradiation Test in Reactor (원자로 내 핵연료조사시험용 압력용기조립체 설계)

  • Park, Kook-Nam;Lee, Jong-Min;Chi, Dae-Young;Park, Su-Ki;Lee, Chung-Young;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.383-387
    • /
    • 2004
  • The Fuel Test Loop (FTL) consists of In-Pile Test Section (IPS) and Out-of-Pile System (OPS). The test condition in IPS such as pressure, temperature and quality of the main cooling water, can be controlled by the OPS. The FTL has been developed to be able to irradiate three pins to the core irradiation hole (IR1 hole) by considering for its utility and user's irradiation requirement. The IPS vessel assembly (IVA) consists of IPS head, outer pressure vessel, inner pressure vessel, inner assembly and test fuel carrier. The IVA is approximately 5.6 m long and fits within a 74 mm in diameter envelope over the full height of the chimney. Above the top of the chimney, the head of the IPS is enlarged to allow the closure flanges and pipe work connections. IVA was designed to test the CANDU and PWR nuclear fuel pin together. Specially, wished to minimize interference by nuclear fuel change in design and synthesize these items and shape design for IVA.

  • PDF

Wear Of Resin Composites Polymerized By Conventional Halogen Light Curing And Light Emitting Diodes Curing Units (HALOGEN LIGHT CURING UNIT 과 LIGHT EMITTING DIODES CURING UNIT 을 이용하여 중합되어진 복합레진의 마모 특성 비교)

  • 이권용;김환;박성호;정일영;전승범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1057-1060
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion with sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed the least wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as a curing unit for composite resin restorations.

  • PDF

Capacitance Swing and Capacitance Ratio of GaN-Based Metal-Semiconductor-Metal Two-Dimensional Electron Gas Varactor with Different Dielectric Films

  • Tien, Chu-Yeh;Kuei, Ping-Yu;Chang, Liann-Be;Hsu, Chien-Pin
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1720-1725
    • /
    • 2015
  • The performance of the AlGaN/GaN MSM-2DEG varactor with different dielectric films deposited by the E-beam deposition is investigated in detail. The capacitance swing and the capacitance ratio of the varactor without dielectric film as well as with, SiO2, Gd2O3, and Si3N4 films, respectively, are determined by electrodes of varying areas. The maximum capacitance, the minimum capacitance and the capacitance ratios are proportional to the increasing of the electrode areas. The capacitance ratio determined by the maximum and the minimum capacitance is found to be 18.35 (with Si3N4 dielectric film) and 149.51 (without dielectric film), respectively. The transition voltages of the fabricated varactors are almost the same for a bias voltage of about ±5 V and leakage current can be lower three orders of magnitude while the varactors with dielectric films. The tunability of the capacitance ratio makes the AlGaN/GaN MSM-2DEG varactor with a dielectric film highly useful in multirange applications of a surge free preamplier.

Dual Birdcage RF Coil for Leg MR Angiography (하지 MR Angiography를 위한 Dual Birdcage RF 코일)

  • 양윤정;김선경;최환준;김호철;오창현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 1997
  • A dual birdcage RF coil is proposed for MRI and MRA of the human leg. The proposed coil c can be used to cover the whole human leg by imaging upper and lower parts of the leg separately. In the conventional leg imaging scheme using a single RF coil, the leg has to be r relocated when changing the position of the RF coil thus causing problems in matching the i images from two sets of coils. When using the proposed dual RF coil, however, only the bed h has to be moved to select the imaging region while only one part of the dual coil is used each t time by using current switching and PIN diodes. The utility of proposed coil has been verified b by volunteer MRI and MRA and the imaging results show that the coil is useful for the clinical MRI and MRA of the leg.

  • PDF

Heat/Mass Transfer for Impingement/Effusion Cooling System with Circular Guide (원형가이드 설치에 따른 충돌제트/유출냉각에서 열/물질전달 특성)

  • Hong, Sung-Kook;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1147-1154
    • /
    • 2006
  • An experimental investigation was conducted to enhance the heat/mass transfer for impingement/effusion cooling system when the initial crossflow was formed. For the improvement of heat transfer, the circular guide is installed on the injection hole. At the fixed jet Reynolds number of 10,000, the measurements were carried out for blowing ratios ranging from 0.5 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result presents that the circular guide protects the injected jet from the initial crossflow, increasing the heat/mass transfer. The heat transfer of stagnation region is hardly changed regardless of the blowing ratio. The secondary peak is obviously formed by flow transition to turbulent flow. At high blowing ratio of 1.5, the circular guide produces $26{\sim}30%$ augmentation on the averaged heat/mass transfer while the case without circular guide leads to the low and non-uniform heat/mass transfer. With the increased heat/mass transfer, the installation of circular guide is accompanied by the increase of pressure loss in the channel. However, the pressure drop caused by the circular guide is lower than that for other cooling technique with the circular pin fin.

Characterization of Mucilage Produced from the Solid-state Fermentation of Soybean Grit by Bacillus firmus

  • Jang, Eun-Kyung;Seo, Ji-Hyun;Park, Seung-Chun;Yoo, Byoung-Seung;Lee, Sam-Pin
    • Food Science and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.722-727
    • /
    • 2007
  • Mucilage containing ${\gamma}-polyglutamic$ acid (PGA) was efficiently generated by the solid-state fermentation (SSF) of soybean grit by Bacillus firmus NA-1. B. firmus NA-1 was shown to be a glutamate-dependent strain for PGA production. The SSF of soybean grit was optimized in order to produce mucilage with a fortification of 5% glutamate, resulting in higher levels of mucilage production (6.14%) and a higher consistency index ($1.1\;Pa\;sec^n$). The sticky mucilage was comprised of 38% PGA, 7% levan, and some biopolymers. With regard to the viscoelastic properties of the mucilage solution, the viscous modulus (G") obtained from soybean grit fortified with 5% glutamate was approximately 64 times higher titan that of the mucilage solution obtained without glutamate. Although the addition of glutamate in the SSF of soybean grit influenced the rate of PGA production, the molecular weight of PGA remained unaltered, and was detected in a range between 1,400-1,440 kDa.

Fatigue Characteristics of PZT Thin Films Deposited by ECR-PECVD

  • Chung, Su-Ock;Lee, Won-Jong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.4
    • /
    • pp.177-185
    • /
    • 2005
  • Fatigue characteristics of lead zirconate titanate (PZT) films deposited by electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) were investigated. The fatigue characteristics were investigated with respect to PZT film thickness, domain structure, fatigue pulse height, temperature, electrode materials and electrode configurations. The used top and bottom electrode materials were Pt and $RuO_2$. In the fatigue characteristics with fatigue pulse height and PZT film thickness, the fatigue rates are independent of the applied fatigue pulse height at the electric field regions to saturate the P-E hysteresis and polarization $(P^*,\;P^A)$ characteristics. The unipolar and bipolar fatigue characteristics of PZT capacitors with four different electrode configurations $(Pt//Pt,\;Pt//RuO_2,\;RuO_2//Pt,\;and\;RuO_2//RuO_2)$ were also investigated. The polarization-shifts during the unipolar fatigue and the temperature dependence of fatigue rate suggest that the migration of charged defects should not be expected in our CVD-PZT films. It seems that the polarization degradations are attributed to the formation of charged defects only at the Pt/PZT interface during the domain switching. The charged defects pin the domain wall at the vicinity of Pt/PZT interface. When the top and bottom electrode configurations are of asymmetric $(Pt//RuO_2,\;RuO_2//Pt)$, the internal fields can be generated by the difference of charged defect densities between top and bottom interfaces.

Surface wettability and contact angle analysis by dissipative particle dynamics

  • Lin, Tzung-Han;Shih, Wen-Pin;Chen, Chuin-Shan
    • Interaction and multiscale mechanics
    • /
    • v.5 no.4
    • /
    • pp.399-405
    • /
    • 2012
  • A dissipative particle dynamics (DPD) simulation was presented to analyze surface wettability and contact angles of a droplet on a solid platform. The many-body DPD, capable of modeling vapor-liquid coexistence, was used to resolve the vapor-liquid interface of a droplet. We found a constant density inside a droplet with a transition along the droplet boundary where the density decreased rapidly. The contact angle of a droplet was extracted from the isosurfaces of the density generated by the marching cube and a spline interpolation of 2D cutting planes of the isosurfaces. A wide range of contact angles from $55^{\circ}$ to $165^{\circ}$ predicted by the normalized parameter ($|A_{SL}|/B_{SL}$) were reported. Droplet with the parameters $|A_{SL}|>5.84B{_{SL}}^{0.297}$ was found to be hydrophilic. If $|A_{SL}|$ was much smaller than $5.84B{_{SL}}^{0.297}$, the droplet was found to be superhydrophobic.

Dorsal Wedge Osteotomy Using Bioabsorbable Pins for the Treatment of Freiberg's Disease (중족골두 무혈성 괴사에서 생체흡수성 핀으로 고정한 배측 쐐기 절골술)

  • Gong, Hyun-Sik;Baek, Goo-Hyun;Kim, Ji-Hyeong;Chung, Moon-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • Purpose: To present the procedure and results of dorsal wedge osteotomy fixated by bioabsorbable polyglycolide pins for the treatment of symptomatic Freiberg's disease. Materials and Methods: From January 1997 to December 2002, six patients with Freiberg's disease underwent dorsal wedge osteotomy of the metatarsal neck to bring the healthy plantar part of the metatarsal head into articulation. Bioabsorbable polyglycolide pins were used for the fixation and short-leg walking cast was applied for 4 weeks. Results: All patients returned to full daily activities without pain in three months after the operation. Radiographically, solid healing of the osteotomy was observed at average ten weeks. The active range of motion of the metatarsophalangeal joint increased by a mean gain of 30 degrees, and no complication such as displacement, osteolysis or sinus formation was observed. Conclusion: Dorsal wedge osteotomy fixated by bioabsorbable pins for patients with symptomatic Freiberg's disease is effective procedure that provides relatively early range of motion exercise and avoids second procedure for implant removal.

  • PDF