• 제목/요약/키워드: Pin Joint

검색결과 172건 처리시간 0.027초

An experimental study of the behaviour of double sided bolted billet connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.603-622
    • /
    • 2018
  • Precast concrete structures are erected from individual prefabricated components, which are assembled on-site using different types of connections. In the present design of these structures, beam-to-column connections are assumed pin jointed. Bolted billet beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is currently limited information concerning their detailed structural behaviour under vertical loadings. The experimental work has involved the determination of moment-relative rotation relationships for semi-rigid precast concrete connections in full-scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and bolt arrangements conformed to successful commercial practice. Proprietary hollow core floor slabs were tied to the beams by 2T25 tensile reinforcing bars, which also provide the in-plane continuity across the connections. The contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. The flexural strength of the connections in the double-sided tests was at least 0.93 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.94 to 1.94 times the flexural stiffness of the attached beam. In general, the double-sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided bolted billet connection test results are presented in this paper. The behaviour of single sided bolted billet connection test results is the subject of another paper.

CFT기둥과 합성보로 구성된 CJS합성구조시스템의 유한요소해석 연구 (Finite Element Analysis Study of CJS Composite Structural System with CFT Columns and Composite Beams)

  • 문아해;신지욱;임창규;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.71-82
    • /
    • 2022
  • This paper presents the effect on the inelastic behavior and structural performance of concrete and filled steel pipe through a numerical method for reliable judgment under various load conditions of the CJS composite structural system. Variable values optimized for the CJS synthetic structural system and the effects of multiple variables used for finite element analysis to present analytical modeling were compared and analyzed with experimental results. The Winfrith concrete model was used as a concrete material model that describes the confinement effect well, and the concrete structure was modeled with solid elements. Through geometric analysis of shell and solid elements, rectangular steel pipe columns and steel elements were modeled as shell elements. In addition, the slip behavior of the joint between the concrete column and the rectangular steel pipe was described using the Surface-to-Surface function. After finite element analysis modeling, simulation was performed for cyclic loading after assuming that the lower part of the foundation was a pin in the same way as in the experiment. The analysis model was verified by comparing the calculated analysis results with the experimental results, focusing on initial stiffness, maximum strength, and energy dissipation capability.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 문형라멘 구조의 수평가력 성능평가 (Lateral Load Performance Evaluation of Larch Glulam Portal Frames Using GFRP-Reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.30-39
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 Glass Fiber Reinforced Plastic (GFRP)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하여 낙엽송 집성재 문형라멘 구조의 수평가력 성능평가를 실시하였다. 실험결과 GFRP rod와 에폭시 접착제를 이용한 삽입 접착형 접합부는 기존의 접합철물을 이용한 실험체와 비교하여 항복내력, 종국내력, 초기강성이 각각 49%, 52%, 61% 낮게 측정되었다. 이러한 접합부는 GFRP rod와 집성재 간의 접착력이 중요한 내력 기구로 현장적용 시 문제가 발생할 수 있는 가능성이 크다고 판단된다. 반면, GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 이용한 실험체는 집성재 슬릿 접합부의 단면적 손실이 큼에도 불구하고 항복내력, 종국내력, 초기강성, 소성률이 전부 3% 이내로 측정되었다. 게다가 사이클에 대한 강성변화율도 35%로 가장 낮게 측정되며 접합철물을 이용한 실험체와 거의 동등한 성능을 발휘한 것을 확인하였다.

동측 원위 비골 지주를 이용한 경-거-종골 관절 유합술 (Tibiotalocalcaneal Arthrodesis Using Ipsilateral Distal Fibula Buttress)

  • 조세현;이정수;정순택;박형빈;황선철;정재헌;차민석
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.213-217
    • /
    • 2006
  • Purpose: To evaluate the clinical and radiological results of tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress which had advantages of extended operative field and release of contracted soft tissue. Materials and Methods: We retrospectively reviewed 4 postraumatic compartment syndrome, 2 residual poliomyelitis, 1 posttraumatic osteoarthritis with subtalar joint infection and 1 posttarumatic sciatic nerve palsy patients who underwent a tibio-talo-calcaneal arthrodesis from April, 1996 to March, 2002. Each of the cases was notable for a severe rigid equinovarus, persistent pus drainage of calcaneal area and paralytic foot. The mean duration of follow up was 18 months (range, $13{\sim}42$ months). The pain, function and alignment were evaluated by the modified ankle hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS) and patients satisfaction clinically. The radiological union were evaluated by plain AP and lateral radiographs. Results: The AOFAS score improved from 58 points (range, $47{\sim}78$) preoperatively to 82 (range, $60{\sim}89$) postoperatively. Patents satisfaction checked at 12 months after operation had favorable results (excellent and good 80%). Union rate was 100% radiographically and the mean duration of union was 12.5 weeks (range $8{\sim}22$ weeks). There was 2 cases of superficial pin tract infection and one protrusion of screw. Conclusion: Tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress was good modality of arthrodesis which provides wide operative field and release of contracted soft tissue in some cases of contracted foot.

  • PDF

봉형 GFRP를 삽입접착한 낙엽송 집성재 접합부의 모멘트저항 성능 평가 (Moment Resistance Performance Evaluation of Larch Glulam Joint Bonded in Glass Fiber Reinforced Plastic Rods)

  • 이인환;송요진;정홍주;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권1호
    • /
    • pp.60-67
    • /
    • 2015
  • 국내산 낙엽송 집성재와 봉형 GFRP의 접착성능을 평가하기 위해 집성재에 선공을 한 후 봉형 GFRP를 삽입하고 접착제로 목재와의 간극을 충진시켜 인발시험편을 제작하였다. 인발시험편은 접착 깊이, 접착층 두께, 접착제 종류를 다르게 적용하여 실험하였다. 봉형 GFRP를 삽입접착한 캔틸레버형 라멘구조 시험체는 인발시험 결과를 토대로 제작, 강판삽입형 시험체와 모멘트 저항 성능을 비교검토 하였다. 인발시험결과 봉형 GFRP의 삽입깊이가 봉형 GFRP 직경의 5배일 때 가장 우수한 접착력이 측정되었으며, 접착층 두께는 1 mm일 경우 2 mm일 때보다 17%~29% 향상된 접착력이 측정되었다. 또한 폴리우레탄(poly-urethane) 접착제를 사용한 시험편이 레조시놀(resorcinol) 접착제를 사용한 시험편보다 2.9~4.0배 높은 성능을 발휘하였다. 봉형 GRFP로 접합한 캔틸레버형 라멘구조 시험체는 드리프트 핀을 사용한 강판삽입형 시험체와 비교하여 평균 0.82배 낮은 모멘트 저항 성능이 측정되었지만 초기강성은 0.93배로 대등한 성능을 보였다.

구치부 지지 소실에 의한 전치부 마모 가속화 환자의 수복: 증례보고 (Restoration of patient accelerating anterior teeth wear by loss of posterior support: Case report)

  • 최혜진;이재훈
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.382-388
    • /
    • 2019
  • 구치부가 상실되면 전치부 저작이 증가하게 되어 상대적으로 전방부에 교합력이 집중된다. 이로 인해 전방부 치아의 마모와 교합성 외상이 발생하고 상실된 치아로 인해 대합치의 정출과 교합부조화가 발생할 수 있다. 본 증례의 67세 여환에서 양측 상악 구치부, 좌측 하악 구치부의 소실, 상하악 전치부의 과도한 마모 및 다수치아의 정출이 관찰되었다. 진단모델은 수직고경 및 악간공간을 평가하기 위해 교합기에 중심위로 마운팅하였다. 보철물 제작을 위한 공간을 확보하기 위해 전치부 핀 기준 3 mm의 수직고경 증가를 동반하여 진단왁스업을 시행하였다. 진단왁스업을 참고하여 임시수복물을 제작하였으며, 환자의 구내에서 확인하였고 이를 참고하여 최종보철 수복을 진행하였다. 수직고경의 변화에 대한 적응을 평가하기 위해 3달 이상의 경과 관찰기간을 가졌으며 저작기능의 회복여부와 턱관절 및 근육 저작에 불편감이 없는 것을 확인하였다. 일련의 치료 과정을 통해 심미적, 기능적으로 만족스러운 결과를 얻었기에 보고하고자 한다.

$Al_2O_{3f}/SiC_p$ 금속복합재료의 섬유방향과 혼합비가 윤활마모특성에 미치는 영향 (Effects of Fiber Orientations and Hybrid Ratios on Lubricant Tribological Characteristics of $Al_2O_{3f}/SiC_p$ Reinforced MMCs)

  • 왕일기;송정일
    • Composites Research
    • /
    • 제22권5호
    • /
    • pp.15-23
    • /
    • 2009
  • 가압주조법으로 제조한 $Al_2O_3$ 섬유와 SiC 입자 혼합 보강 금속복합재료(MMCs)의 상온과 고온에서 윤활마모특성을 조사하였다. 마모시험은 거리와 온도의 변화에 따라 속도를 고정시켜 25Kgf의 하중하에서 수행하였으며 MMCs의 시험편은 가압의 수평(PR)방향과 수직(N)방향에서 채취하였다. 혼합비의 영향을 관찰한 결과 상온에서는 20%섬유만 보강한 PR방향 MMCs의 마모거동은 N방향 보다 우수한 결과를 보였으나, 혼합보강 MMCs는 반대로 나타내었다. 고온($100^{\circ}C$)에는 모든 MMCs에서 PR방향의 마모거동이 N 방향보다 우수한 결과를 보인 것은 보강재와 마찰면간 윤활필름이 강호작용에 기인한 것으로 밝혀졌다. $150^{\circ}C$에서는 혼합 MMCs의 마모거동은 온도영향으로 PR이 N 보다 우수한 결과를 보였다.

제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료 (Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures)

  • 강충남;김종오;김동욱;고영도;고상훈;유재두;황준호
    • 대한족부족관절학회지
    • /
    • 제1권2호
    • /
    • pp.102-111
    • /
    • 1997
  • 저자들은 1993년 9월부터 1996년 5월까지 본원 정형외과에 입원하여 Pilon 골절로 치료받고 1년 이상 추시 가능하였던 19례(18명)를 대상으로 다음과 같은 결론을 얻었다. 1. Ovadia와 Beals의 분류상 제1형이 2례, 제2형이 3례, 제3형이 10례, 제4형이 1례, 제5형이 3례였고, 제3형이 53%로 가장 많았으며, 교통사고와 추락손상 등 고에너지 손상에 의한 골절이 16례로 전체의 약 84%를 차지하였다. 2. 손상의 정도가 비교적 적은 제1형과 제2형에서는 모두 양호 이상의 임상결과를 나타내었으며, 제4형과 5형에서는 손상의 정도가 심하고 이로인한 정확한 정복의 어려움으로 인해 보통 이하의 성적을 나타내었다. 3. 합병증은 외상후 관절염이 6례로 가장 많았으며 손상정도가 심한 3형 이상에서 정확한 정복이 이루어지지 않은 경우에 발생하였으며, 방사선학적 평가가 보통이하였던 제3형 3례에서 부정 유합이 발생하였으나 임상결과와의 연관성은 없었다. 4. 저자들은 제한된 관혈적 정복 및 내고정술로 연부조직의 합병증을 현격히 줄일 수 있었으며, 손상의 정도가 적고 정확한 정복이 가능한 경우, Pilon 골절의 좋은 치료 술식의 하나라고 사료된다.

  • PDF

사지 구제술 합병증 치료에서 연부조직 연장을 위한 한시적 외고정 기기의 유용성 (Temporary Use of External Fixators for Soft Tissue Lengthening in the Treatment of Complications after Limb Salvage Surgery)

  • 윤필환;강현귀;김갑중;오주한;이상훈;이상기;김한수
    • 대한골관절종양학회지
    • /
    • 제11권2호
    • /
    • pp.134-140
    • /
    • 2005
  • 목적: 종양 대치물을 이용한 사지 구제 술 후 발생한 심부감염, 해리, 또는 하지 단축 등의 합병증으로 종양 대치물을 제거한 후 단계별 치료를 하는 과정에서 연부 조직 구축으로 인해 초래되었거나 또는 합병증 치료 시작 당시부터 있었던 하지 단축에 대하여 연부조직 연장 만을 위하여 외고정 기기를 한시적으로 사용한 결과를 평가하고 그 유용성을 알아 보고자 하였다. 대상 및 방법: 악성 골 종양으로 종양대치물을 이용하여 사지구제술을 받은 후 발생한 합병증으로 연부 조직 구축 및 하지 단축이 발생되어, 연부 조직 연장을 위해 외고정 기기(Dyna-extor$^{(R)}$)를 사용하였던 5명의 환자 6예를 대상으로 하였다. 외고정 기기는 골격 결손부위의 근위와 원위 정상 뼈 부분에 금속핀을 삽입 후 설치 하였다. 외부 고정기 연장은 술 후 약 3일부터 하였으며, 신경학적 증상이 나타나지 않는 범위에서 하루에 2~3 mm 이상씩 시행하였다. 결과: 치료 부위는 원위 대퇴골이 3예, 근위 경골이 2예였다. 최초 사지 구제술시의 평균연령은 13.4세(9~19세)였으며, 외부 고정기를 설치할 때의 평균연령은 22.2세(15~29세)로 최초 사지구제술 후 합병증으로 하지 단축이 발생되어 외부 고정기를 설치할 때까지의 기간은 평균 8.8년(3~14년)이었다. 4명의 환자 5예에서 평균 착용 기간은 37일(25~50일)에 평균 5.8 cm을 연장 하였으며, 1명의 환자는 150일 동안 착용하여 7.2 cm을 연장하였다. 외부 고정기 제거 3명의 환자에서 종양 대치물을 재삽입 하였고, 2예의 환자는 슬관절 유합술을 시행하였다. 이후 평균 추시 기간은 22개월이었으며 감염은 재발하지 않았다. 결론: 종양 대치물을 이용한 사지 구제술 후의 합병증으로 또는 합병증의 치료 과정에서 초래되는 연부 조직 구축과 하지 단축에 대하여 외고정 기기를 한시적으로 사용하여 효과적으로 하지 길이를 연장할 수 있었으며, 추후 종양 대치물 재 삽입이나 관절 고정술의 수술을 용이하게 해줄 수 있는 유용한 방법이라고 사료된다.

  • PDF

중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동 (Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio)

  • 이승준;서수연;배문용;김강수
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.441-448
    • /
    • 2014
  • 최근 일련의 연구로부터, 중공이 있는 프리캐스트 콘크리트(hollewed precast concrete, HPC) 기둥를 사용할 경우, 일반적인 PC기둥에 비하여 접합부 콘크리트를 충실하게 채울수 있으며 이에 따라, 접합부의 고정도는 일체식 철근콘크리트(RC)와 같이 향상될 수 있음이 확인되었다. 그러나 충전콘크리트로 중공부가 채워진 후, HPC부재와 충전콘크리트의 강도가 서로 다르고 이 두 부재 사이에는 접촉면이 있음에 따라 합성구조와 같은 거동을 보이게 되며 이는 합성된 기둥의 구조적 거동과 강도에 영향을 미치게 된다. 이 논문에서는 HPC 기둥에서 중공의 크기와 중공부분 콘크리트의 채움 유무에 따른 기둥의 압축강도 시험을 실시하였다. 중공의 비율은 35, 50 그리고 59%이며 실험체의 양단을 단순지지 형태로서 지지한 뒤 중심압축력을 기둥의 상단에 작용시켰다. 또한 압축에 대한 HPC 기둥의 파괴거동을 묘사하기 위하여 유한요소 해석을 실시하였다. 실험 결과, 중공내부가 충전콘크리트로 채워진 기둥에서, PC와 충전콘크리트의 강도차이와 상관없이 중공률은 기둥의 초기강성에 영향을 미치지 않는 것으로 나타났다. 그러나 기둥의 압축강도는 중공률에 반비례하는 것으로 나타났다. 충전콘크리트가 채워지지 않은 HPC기둥의 구조성능은 중공의 직경에 밀접하게 관련이 있는 것으로 나타났으며, 특히, HPC의 두께가 지나치게 얇은 경우에는 국부적인 파괴가 전체 파괴를 지배하는 것으로 나타났다. 이러한 영향을 고려하여 HPC기둥의 압축내력을 산정할 수 있는 식을 제시하였다. 유한요소해석에서는, HPC와 충전콘크리트 사이의 접촉면을 고려할 경우, 해석 결과가 실험 결과와 좋은 대응을 보이는 것으로 나타났다.