• 제목/요약/키워드: Pin Joint

검색결과 172건 처리시간 0.021초

실험계획법에 의한 Al5052 알루미늄 합금의 마찰교반용접특성 (Friction Stir Welding Characteristics of Al5052 Aluminium Alloy by Design of Experiment)

  • 강대민;장진숙
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.11-16
    • /
    • 2015
  • Welding is very popular method for joining two or more metals. In this paper, the three-way factorial design was adopted for obtaining the optimum friction stir welding conditions of Al 5052 alloy. Tools of shoulder diameter of 9, 12, 15 mm and pin length of 1.5 mm were used. Also the material's dimension for welding was $100{\times}100{\times}2mm$, and the tensile specimens were worked by water-jet technique. Welding variables were shoulder diameter, rotating speed of tool and welding speed. As far as this work is concerned, optimum condition for friction stir joint of Al 5052 alloy was predicted as the shoulder diameter of 15 mm, welding speed of 500mm/min and rotating speed of 1000 rpm. In addition, the presumed range of tensile strength under the optimal conditions is estimated to be $208.3{\pm}5.7$ MPa with 99% reliability.

후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동 (Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction)

  • 김철웅;배지훈;이호상;왕준호;박종웅;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

피라미드 트러스 코어 단위셀의 기계적 특성에 관한 해석적 및 수치적 연구 (Analytical and Numerical Study on Mechanical Behavior of Unit Cell of Pyramidal Truss Core Structures)

  • 김상우;이영선;강범수
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.623-631
    • /
    • 2011
  • Metallic sandwich panels based on a truss core structure have been developed for a wide range of potential applications with their lightweight and multi-functionality. Structural performance of sandwich panels can be predicted from the studies on mechanical behavior of a unit cell of truss core structures. Analytical investigations on the unit cell provide approximated guidelines for the design of overall core structures for a specific application in short time. In this study, the effects of geometrical parameters on mechanical behavior of a pyramidal shape of unit cell were investigated with analytical models. The unit cell with truss member angle of 45 degree was considered as reference model and other models were designed to have the same weight and projected area but different truss member angle. All truss members were assumed to be connected with pin joint in analytical models. Under the assumptions, the equivalent strength and stiffness of the unit cell under compressive and shear loads were predicted and compared. And finally, the optimum core member angle to have maximum mechanical property could be calculated and verified with FE analysis results.

원위 쇄골 골절 2a 형에서의 경피적 환상 강선 고정술 -1례 보고- (Percutaneus Cerclage Wiring in Distal Clavicle Fracture Type 2a - One Case Report -)

  • 김재화;이순철;조덕연;윤형구;이윤석
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.124-129
    • /
    • 2006
  • Distal clavicular fracture frequently requires operative treatment due to high rate of non-union. The operative technique includes the tension band wiring, K- wire fixation, and cerclage wiring etc. Each method has disadvantages somewhat like pin migration or acromioclavicular joint injury and so on. For the distal clavicular fracture type 2a, because of its oblique fracture line, the cerclage wiring is suitable. We performed the cerclage wiring percutaneously under minimal incision without injury to periosteum for the patient who had the distal clavicular fracture type 2a, and the result was favorable.

견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술 (Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture)

  • 김진섭;전진호;정영기
    • Clinics in Shoulder and Elbow
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

버팀보 해체시 안전성 확보를 위한 응력 해제용 굴절지지대 개발 및 성능 평가 (Development and Performance Evaluation of Rotational Strut Segment for Releasing Stress when uninstalled)

  • 박철용;구일근;김현숙;양지연;김형오
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2018
  • Preloading Strut applied during installation of the wall jack, but additionally serves to minimize the displacement of soil pressure acting upon dissolution due to the difficulty. In this study, we developed an index of support for the release of stress to facilitate the dismantling of the strut uninstall. The refractive support the axial force acting on the strut are supportable, is refracted at minimum load, disassembly should be easy. In order to find the optimal shape and structural stability of the refractive support We have performed the numerical analysis and performance test to determine the final model. We carried out model tests and UTM test in order to understand the refractive performance and durability of the refractive support for optimal model. Results of the test UTM is refracted all shot 5 times within a target hit number, it was found that there is no problem of the refractive performance. Further, the results of model experiments, it was found that to ensure sufficient durability more than the performance target value of the pin joint support structure.

  • PDF

브라켓 및 H-빔 부재가 성수대교 붕괴에 미친 영향 (Effect of Bracket and H-beam Members on the Sungsoo Grand Bridge)

  • 조효남;임종권;안중산
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.422-430
    • /
    • 1998
  • This paper presents the results of a major parametric study on the collapse cause of the Sungsoo Grand Bridge, a Gerber-type continuous truss bridge, which had collapsed just at the 15th year since opening to traffic. Among the various collapse causes such as poor design, poor welding, poor maintenance, and heavy traffic loads, this study focuses on the collapse cause assessment incorporating the effects of braket and H-beam members right below the expansion joint of the suspended truss. A local FEM analysis using fine shell elements is carrided out for the more precise estimation of stress range of the vertical pin-connected hanger whose fatigue fracture triggered the collapse of the bridge. Both the conventional S-N approach and the Ang-Munse's fatigue reliability method are used for the evaluation of the fatigue life and fatigue failure probability for the assessment based on all the available results of various field and labolatory tests. From these observations, It may be affirmatively stated that the effects of bracket and H-beam members accelerated the fatigue failure, and thus should be regarded as one of major causes that triggered the bridge collapse

  • PDF

표면실장용 IC 패키지 솔더접합부의 열피로 수명 예측 (A prediction of the thermal fatigue life of solder joint in IC package for surface mount)

  • 윤준호;신영의
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.92-97
    • /
    • 1998
  • Because of the low melting temperature of solder, each temperature cycle initiates an irrecoverable creep deformation at the solder interconnection which connects the package body with the PCB. The crack starts and propagates from the position where the creep deformation is maximized. This work has tried to compare and analyze the thermal fatigue life of solder interconnection which is affected by the lead material, the size of die pad, chip thickness, and interface delamination of 48-Pin TSOP under the temperature cycle ($0^{\circ}C$~1$25^{\circ}C$). The crack initiation position and thermal fatigue life which are calculated by using FEA method are well matched with the results of experiments. The thermal Fatigue life of copper lead frame is extended around 3.6 times longer than that of alloy 42 lead frame. It is maximized when the chip size is matched with the length of the lead. It tends to be extended as the thickness of chip got thinner. As the interfacial delamination between die pad and EMC is increased, the thermal fatigue life tends to decrease in the beginning of delamination, and increase after the delamination grew after 45% of the length of die pad.

  • PDF

A class of actuated deployable and reconfigurable multilink structures

  • Phocas, Marios C.;Georgiou, Niki;Christoforou, Eftychios G.
    • Advances in Computational Design
    • /
    • 제7권3호
    • /
    • pp.189-210
    • /
    • 2022
  • Deployable structures have the ability to shift from a compact state to an expanded functional configuration. By extension, reconfigurability is another function that relies on embedded computation and actuators. Linkage-based mechanisms constitute promising systems in the development of deployable and reconfigurable structures with high flexibility and controllability. The present paper investigates the deployment and reconfigurability of modular linkage structures with a pin and a sliding support, the latter connected to a linear motion actuator. An appropriate control sequence consists of stepwise reconfigurations that involve the selective releasing of one intermediate joint in each closed-loop linkage, effectively reducing it to a 1-DOF "effective crank-slider" mechanism. This approach enables low self-weight and reduced energy consumption. A kinematics and finite-element analysis of different linkage systems, in all intermediate reconfiguration steps of a sequence, have been conducted for different lengths and geometrical characteristics of the members, as well as different actuation methods, i.e., direct and cable-driven actuation. The study provides insight into the impact of various structural typological and geometrical factors on the systems' behavior.

시스템 구성 인자를 고려한 외고정장치 시스템의 강성 해석 (Stiffness Analysis of External Fixation System with System Configuration Parameters)

  • 김윤혁;이현근
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.531-536
    • /
    • 2004
  • 외고정장치를 이용한 골절 치료에서, 골절 부위에서의 절골편간 운동은 골절의 치유과정에 다양한 영향을 미친다고 알려져 있고, 이 미세 운동은 외고정장치-절골편 시스템의 강성과 밀접한 관련이 있다. 그렇기 때문에 최적의 골절 치유 과정을 부여하기 위하여 외고정장치 시스템의 구성 인자와 강성과의 연관성에 대한 이해가 필요하다. 본 연구에서는 장골 골절의 외고정술에 대한 유한요소 해석에서 외고정장치 시스템의 구성인자가 시스템 강성에 미치는 영향을 조사하였다. 이를 위하여, 시스템 정렬, 재료 비선형성, 조인트 유연성 및 가골형성 등을 해석 인자로 선정하였다. 개발된 유한요소 모델은 실험 결과와 유사한 시스템 강성을 나타내었고, 조인트 유연성 및 재료 비선형성의 고려는 시스템 강성 결과를 더욱 정확하게 반영하였다. 시스템 비정렬상태, 조인트 유연성 및 재료 비선형성은 시스템 강성의 감소를, 그리고 골절 부위의 가골형성은 시스템 강성의 증가를 나타내었다. 본 연구 결과는 외고정술시 시스템 강성을 증가시키기 위한 프레임 구성이나 기구 설계 등의 도구로 사용될 수 있을 것으로 기대된다.