• Title/Summary/Keyword: Pilot Scale Test

Search Result 325, Processing Time 0.029 seconds

Practical Use of Self Compacting Concrete to be filled inside the Steel Tube Columns (무다짐 콘크리트를 이용한 높은 40m CFT 기둥의 시공)

  • 김규동;김한준;손유신;이승훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1023-1028
    • /
    • 2003
  • The structure of Tower Palace III Sports Center building was designed as concrete Filled Steel Tube(CFT) Column and the filled-in concrete was designed as high compressive strength of 500kgf/$m_2$. The self compacting concrete(SCC, non-vibrating concrete) with 65$\pm$5cm flow must be applied to this case for filling the CFT by injecting the concrete from the column bottom. Laboratory tests and pilot productions of batcher plant were performed for optimum mix design and the full scale Mock-Up test was performed to check the appicability of the construction method. As a result, we observed that good quality SCC and the pressure change of concrete pump normally used domestically. Based on these results, we have constructed 20-40m height CFT columns successfully.

  • PDF

Atmospheric and Pressurized Operation of a 25 kW MCFC Stack (25 kW급 용융 탄산염 연료 전지 스택의 상압 및 가압 운전)

  • Koh, Joob-Ho;Seo, Hai-Kung;Lim, Hee-Chun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.264-269
    • /
    • 2000
  • As a part of the ongoing effort towards commercial application of high-temperature fuel cell power generation systems, we have recently built a pilot-scale molten carbonate fuel cell power plant and tested it. The stack test system is composed of diverse peripheral units such as reformer, pre-heater, water purifier, electrical loader, gas supplier, and recycling systems. The stack itself was made of 40cells of $6000cm^2$ area each. The stack showed an output higher than 25kW power and a reliable performance at atmospheric operation. A pressurized performance was also tested, and it turned out the cell performance increased though a few cells have shown a symptom of gas crossover. The pressurized operation characteristics could be analyzed with numerical computation results of a stack model.

  • PDF

The Clinical pilot study of Hwangryunhaedok-tang Pharmacopunctue therapy on Post-stroke depression (뇌졸중 후 우울증에 대한 황련해독탕 약침의 안전성 및 유효성 평가를 위한 임상 시험)

  • Je, Jun-Tae;Lee, Sang-Kwan
    • Journal of Pharmacopuncture
    • /
    • v.13 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Objective : The purpose of this study is to determine the efficacy and safely of Hwangryunhaedok-tang Pharmacopuncture (HHT-PA) therapy on post-stroke depression (PSD) in stroke patients. Methods : Fifteen PSD patients has been recruited and evaluated with liver function test (LFT) and renal function lest (RFT) and depression scales, Beck Depress ion Inventory (BDI) and Hamilton Depression Rating Scale (HAM-D) before and after HHT-PA treatment. Results : HAM-D score significantly decreased after HHT-PA treatment regard less of improving of motor function. But BDI score did not decrease significantly. All results of LFT and RFT were in normal range before and after HHT-PA treatment Conclusion : These results showed that HHT-PA decrease PSD symptoms and has safety on stroke patients, although has no effect on improving of motor impairment.

Development of syngas supplying system for BTL (Biomass to Liquid) process (BTL(Biomass to Liquid) 공정을 위한 합성가스 공급 시스템 개발)

  • Kim, Y.D.;Kim, B.J.;Moon, J.H.;Lee, U.D.;Kim, K.S.;Yang, C.W.;Lee, J.W.;Lee, S.H.;Kim, J.H.;Lee, S.B.
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.223-226
    • /
    • 2012
  • Biomass to Liquid (BTL) is an attractive option for using biomass as an renewable energy. A syngas supplying system has been designed for BTL system, based on the Fischer-Tropsche (FT) process, and long-term operation test was conducted. The syngas supplying system is composed of a fluidized bed gasifier, gas cleaning and compression system, and methanol absorption system. Stable operation of more than hundred hours was achieved with several champaigns. In addition, a pilot scale biomass gasifier has been developed for 1 bbl/day BTL system and its performance was evaluated. Some preliminary results and current status of the development of BTL system will be presented.

  • PDF

Experimental study on combustion characteristics of high efficiency oxy-fuel burner (고효율 순산소 버너의 연소 특성에 관한 실험적 연구)

  • Kim, Se-Won;Ahn, Jae-Hyun;Kim, Min-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.57-64
    • /
    • 2002
  • This paper describes the results of a series of experiments executed by using two pilot-scale oxv-fuel burners are designed for maximum capacity of 50,000 kacl/hr, 300,000 kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, swirl vane angle and inlet oxygen temperature on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and inlet oxygen temperature. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, Optimum excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

Construction Technology of High Strength Concrete Designed 800kg/$cm^2$ for High-Rise Building (초고층 건물용 800kg/$cm^2$의 초고강도콘크리트 시공기술)

  • 김규동;이승훈;김규용;손유신;김한준
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.49.2-53
    • /
    • 2003
  • This paper reports the application of high strength concrete designed as 800kg/$cm^2$ on the columns and belt wall of Tower Palace III. The concrete should meet or exceed the requirements of slump of 23cm, ${\sigma}$18H of 100kg/$cm^2$, ${\sigma}$91th of 800kg/$cm^2$. The concrete mixings with 4 different domestic Silica fumes were investigated. Laboratory tests, the pilot productions of batcher plant and the full-scale mock up tests were performed As results of site application, all test results are satisfied with the requirements of columns and belt wall.

  • PDF

Experimental study on combustion characteristics of oxy-fuel glass melting furnace (순산소를 이용한 유리 용해로의 연소특성에 관한 실험적 연구)

  • Kim, Se-Won;Ahn, Jae-Hyun;Kim, Yong-Mo;Shin, Myung-Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The results of a series of experiments executed by using two pilot-scale oxy-fuel burners are presented. The oxy-fuel burners are designed for maximum capacity of 50,000kcal/hr, 200,000kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, and swirl vane angle on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple at various points of the flame. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and momentum. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, optimum burner type, excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

An Information Technology Usage Level Assessment Model for Service Industry (서비스산업의 IT활용수준 평가모델 개발)

  • Kim, Hyun-Soo
    • Journal of Information Technology Services
    • /
    • v.7 no.1
    • /
    • pp.255-274
    • /
    • 2008
  • The purpose of this research is to develop an information technology (IT) usage level assessment model for service industry. It is necessary to develop an assessment model for service industry's IT usage to improve service productivity. However, it is not easy to develop assessment models due to service industry's diversity. In this paper a generic IT usage assessment model for service industry has been developed and validated through a descriptive approach. Key factors affecting service productivity have been identified and analysed. A pilot test on IT usage level has been performed to investigate the relevance and importance of IT usage indicators (factors). As a result, a set of effective IT usage indicators for service industry have been found. A short-cut model and a full scale model have been proposed for efficient and effective usage. The results of this study can be used for enhancement of service industry productivity through the increase of IT usage level.

The Pilot-scale Treatability test of Co-Composting for The Remediation of Diesel Contaminated Soil in The Winter (동절기 유류 오염토양 복원을 위한 Co-Composting 기술의 현장 적용성 연구)

  • 마정재;고형석;황종식;정민정;최상일;김국진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.04a
    • /
    • pp.26-28
    • /
    • 1999
  • 동절기 급격한 온도 저하로 인한 적용한계를 극복하기 위하여 composting 기술을 현장에 적용하여 적용 가능성을 검토하고 온도 변화에 따른 분해 특성을 검토하였다. 기초 실험을 통해 영양원과 유류분해 미생물의 첨가에 따른 분해 효율을 점검한 결과 초기 유효 미생물 (유류분해 미생물)의 농도가 낮고 영양원(N, P source)의 불균형으로 인해 영양원의 첨가와 유류분해 미생물을 동시에 투입하는 것이 바람직한 것으로 나타났으며, 동절기 낮은 온도를 극복하기 위해 퇴비를 투입한 Co-composting 기술은 주입된 퇴비의 영향으로 pile 내부의 온도가 30-40일 동안 중온상태를 유지하였으며, 제거효율은 91%로 나타났다. 따라서 유류 오염토양을 복원함에 있어서 동절기에도 별도의 시설투자 없이 효율적으로 유류를 분해시킬 수 있는 CO-Composting 기술의 적응 가능성이 확인되었으며, 난분해성 물질의 생물학적 분해에 있어서도 다양하게 적용될 수 있을 것으로 판단된다.

  • PDF

A Proposal for Generation of Digital Elevation Models in Korea

  • Lee, Chang-Kyung;Park, Byung-Gil;Kim, Young-An;Min Heo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.02a
    • /
    • pp.73-81
    • /
    • 2004
  • National Geographic Information Institute (NGII) in Korea, through National Geographic Information System (NGIS) Program, has prepared to generate and disseminate digital elevation data for Korea. This is a pilot research to propose a policy for generation, maintenance, and supply of Korea Digital Elevation Data (KDED). Customer demands for accuracy and resolution of DEM was surveyed through questionnaire. In order to investigate the quality, the technical efficiency and the production cost, a tentative DEM in a small test site was generated based on digital topographic maps (original paper map scale 1 :5,000), analytical plotter, and LIDAR. Accuracy standard for KDED was derived based on source data and generation methods. As results of this research, we recommend uniformly spaced grid model for KDED. Its preferable grid space is 5m in urban and its vicinity; and 10m in field and mountainous area. LIDAR has been valuated as a proper KDED generation method fulfilling customers demand for the accuracy.

  • PDF