• 제목/요약/키워드: Pile capacity

검색결과 748건 처리시간 0.024초

Dynamic analyses and field observations on piles in Kolkata city

  • Chatterjee, Kaustav;Choudhury, Deepankar;Rao, Vansittee Dilli;Mukherjee, S.P.
    • Geomechanics and Engineering
    • /
    • 제8권3호
    • /
    • pp.415-440
    • /
    • 2015
  • In the present case study, High Strain Dynamic Testing of piles is conducted at 3 different locations of Kolkata city of India. The raw field data acquired is analyzed using Pile Driving Analyzer (PDA) and CAPWAP (Case Pile Wave Analysis Programme) computer software and load settlement curves along with variation of force and velocity with time is obtained. A finite difference based numerical software FLAC3D has been used for simulating the field conditions by simulating similar soil-pile models for each case. The net pile displacement and ultimate pile capacity determined from the field tests and estimated by using numerical analyses are compared. It is seen that the ultimate capacity of the pile computed using FLAC3D differs from the field test results by around 9%, thereby indicating the efficiency of FLAC3D as reliable numerical software for analyzing pile foundations subjected to impact loading. Moreover, various parameters like top layers of cohesive soil varying from soft to stiff consistency, pile length, pile diameter, pile impedance and critical height of fall of the hammer have been found to influence both pile displacement and net pile capacity substantially. It may, therefore, be suggested to include the test in relevant IS code of practice.

Polymer Base Bored Pile in Bangkok Subsoils

  • Teparaksa, Wanchai
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.407-426
    • /
    • 2008
  • The bentonite slurry has been used as the stabilize suspension for wet process bored pile construction in Thailand. The bentonite suspension has benefit on filtration in the sand layer, but it creates thick cake film along pile shaft and loose sedimentation at pile toe. The base grouting technique was widely used to rectify the soft base or loose sedimentation problem of bored pile. The base grouting technique was not increased only end bearing capacity, but was also more increase in skin friction capacity of the bored piles. The comprehensive researches on base grouting was carried out by installing PVC casing inside the shaft to allow the drilling through the pile base in order to collect the soil sample below the pile tip. The polymer based slurry recently was used to replace the bentonite slurry to overcome the thick cake film along pile shaft as well as loose sedimentation at pile toe. The extent research on polymer slurry by physical model was performed to verify the real behavior of polymer. The appropriate mixing ratio of polymer was proposed. The design skin friction coefficient, $\beta$ and end bearing coefficient, Nq, for sand layer base on fully instrumented tested pile were proposed. The application on remedial of the lose capacity bored pile with large displacement in Bangladesh was proposed and discussed.

  • PDF

말뚝직경이 재단말뚝의 폐색정도와 지지력에 미치는 영향 (Effects of Pile Diameter on the Plugging Rate and Bearing Capacity of Open -Ended Piles)

  • 백규호;김영상;이승래
    • 한국지반공학회지:지반
    • /
    • 제12권2호
    • /
    • pp.85-94
    • /
    • 1996
  • 말뚝직경이 개단말뚝의 폐색정도와 지지력에 미치는 영향을 규명하기 위하여 응력상태와 상대밀도의 조절이 가능한 토조와 직경이 다른 세개의 모형말뚝을 이용하여 모형말뚝실험을 수행하였다. 모형말뚝은 말뚝의 지지력 성분을 분리측정하기 위하여 직경이 다른 두개의 파이프로 만들어졌다. 실험결과에 의하면 말뚝이 완전폐색 상태로 되는 관입깊이는 말뚝직경과 지반의 상대밀도가 증가할수록 커지는 것을 알 수 있었으며, 관입비와 관내토 증분비가 동일하더라도 단위 관내토 지지력은 말뚝의 직경이 커질수록 감소하는 경향을 보였다. 그러나 기존의 지지력 산정식은 말뚝의 관입비나 폐색정도가 동일한 상태에 대하여 관내토 지지력은 말뚝의 직영에 관계없이 일정하거나 직경이 증가할수록 커지는 결과를 주고 있다. 이는 본 연구의 실험결과와 상반되는 것으로서 관내토 지지력의 산정시 말뚝의 폐색정도 뿐만 아니라 크기효과도 고려하는 것이 필요한 것으로 밝혀졌다.

  • PDF

동재하시험을 이용한 모래지반의 말뚝지지력 산정 (Evaluation of Bearing Capacity of Piles in Sand Using Pile Driving Analyzer)

  • 이우진;석종수
    • 한국지반공학회지:지반
    • /
    • 제13권5호
    • /
    • pp.145-154
    • /
    • 1997
  • 말뚝재하시험방법 중 정적재하시험은 시험에 소요되는 시간과 비용측면에서 불리하여 이를 개선하기 위한 여러 가지의 시험방법이 개발되어 소개되고 있다. 국내에 소개된 시험방법으로는 동재하시험으로 불리는 항타분석기 (PDA : Pile Driving Analyzer)를 이용한 방법을 비롯하여 STATNAMIC. Osterberg cell등이 있다. 이들 중 동재하시험의 사용은 상당히 활성화되어 있는 실정이나 지반조건과 말뚝시공방법에 따라서는 지지력산정시 추가적인 해석모델을 사용하여야 보다 정확한 지지력을 평가 할 수 있는 것으로 알려져 있다. 본 논문에서는 현장에서 수행한 정적 및 동적 재하시험결과의 비교1분석으로 부터 주로 SIP말뚝에 대한 동재하시험시 발생할수 있는 기하감쇠(geometrical damping)의 영향을 고찰하였다. 해석결과로 부터 기하감쇠가 발생한 지반의 경우 CAPWAP에 의해 산정된 지지력이 정재하시험에 의한 지지력에 비해 30~60% 정도 과소평가 되었으며 이때 말뚝주면에 대한 Smith의 감쇠계수 (SSkn)가 1.0 sec/m를 초과 하였다. CAPWAP해석시 기하감쇠를 고려한 해석모델을 사용함으로써 정재하 시험결과와 근사한 지지력을 얻을 수 있었으며 SSkn값도 0.7sec/m이하의 일반적인 범위로 해석되었다.

  • PDF

Piled Raft 거동특성에 관한 실험적 연구 (An Experimental Study on Behavior for the Piled Raft)

  • 권오균;이승현;오세붕;임종석;이활
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 기초기술학술발표회
    • /
    • pp.77-89
    • /
    • 2002
  • To analyze a bearing capacity for pile groups, a number of model tests have been done and theoretical methods studied. In the case of design of group pile bearing capacity is calculated with only pile capacity. But uncertainty of bearing capacity and behavior of foundation cap(raft) leads to conservative design ignoring bearing effects of foundation cap. In the case of considering bearing capacity of foundation cap, the simple sum of bearing capacity of foundation cap and pile groups cannot be the bearing capacity of total foundation system. Since cap-pile-soil interaction affects the behavior of pile groups. Thus, understanding cap-pile-soil interaction is very important in optimal design. In this paper, the piled raft behavior is studied through model tests of 2$\times$2, 2$\times$3, 3$\times$3 pile group. Changes of behavior of pile group foundation by touching effects of foundation cap with soil are studied. Also changes of spacing between piles. Foundation cap is made of rigid steel plate and piles are made steel pipes. From this model tests, the changes of behavior changes of pile groups by touching effects of foundation cap with soil are studied.

  • PDF

해진시 심해에 설치된 개단말뚝의 안정성에 관한 모형실험 연구 (An Experimental Study on the Stability of Open-ended Pipe Piles Installed in Deep Sea during the Simulated Seaquake)

  • 남문석;최용규
    • 한국지진공학회논문집
    • /
    • 제3권3호
    • /
    • pp.45-54
    • /
    • 1999
  • 지진의 연직성분에 의해 유발된 해진시 단일개단말뚝의 거동에 관한 이전의 연구들에서 단일개단말뚝의 지지력은 완전히 감소되었으며 관내토의 폐색도 완전히 파괴된 것으로 밝혀졌다 그러나 개단말뚝이더라도 말뚝의 관입길이가 길 경우 해진에 대하여 말뚝이 안정성을 유지할수 있고 개단강관말뚝일 경우에는 비교적 관입깊이가 짧을 경우에도 해진에 대하여 안정성을 유지할 수있을 것으로 예상된었다 본 연구에서는 초세립질 포화모래지반을 담고 잇는 소형압력토조에 단일개단말뚝 2개 또는 4개의 개단무리말뚝을 관입길이 7-40m로 모델링하여 관입시켰으며 각각의 말뚝에 대하여 압축정재하시험을 실시한후 극한지지력의 약 95%의 압축하중을 재하시킨 상태에서 해진의 진동을 작용시키면서 지지력의 감소를 확인하였고 해진 작용후의 각각의 말뚝에 대하여 압축정재하시험을 실시하였다. 해진시 천해에 설치된 단일개단말뚝과 군말뚝의 지지력은 감소되지 않았다 그러나 심해에 설치된 말뚝의 안정성은 말뚝의 지중관입 깊이에 좌우되었다 즉 27m이상 관입된 단일개단말뚝의 지지력은 안정하였으며 13m이상 관입된 2개 및 4개 군말뚝은 안정하였다 그런 7m 관입된 2개 군말뚝은 파괴되었으며 7m 관입된 4개 군말뚝의 지지력은 15%만큰 저감되었다.

  • PDF

수치해석을 이용한 이중 강-콘크리트 합성말뚝 연직지지력 평가 (Estimation on End Vertical Bearing Capacity of Double Steel-Concrete Composite Pile Using Numerical Analysis)

  • 김정수;구정민;김문옥;정충열;추연욱
    • 한국지반환경공학회 논문집
    • /
    • 제23권12호
    • /
    • pp.5-15
    • /
    • 2022
  • 이중 강-콘크리트 합성말뚝의 설계를 위한 지지력 평가 방법이 정립되지 않아 기존 강관말뚝 설계 지지력식이 활용되고 있다. 그러나 이들 설계식 간 지지력 예측 결과가 상이할 뿐만 아니라 일반적으로 가장 보수적인 결과를 채택하게 된다. 이러한 말뚝 지지력 평가방법은 설계의 신뢰성 및 경제성을 낮추게 된다. 본 논문은 수직하중을 받는 이중 강관 내 콘크리트 채움된 신형식 합성단면(DSCT) 말뚝의 역학적 거동을 수치해석적으로 조사하고, 여러 DSCT 말뚝 조건변화에 따른 연직지지력을 분석하였다. DSCT 말뚝 및 인접지반에 대한 축대칭 유한요소모델을 생성하였고, 이를 활용해 근입깊이, 말뚝 선단 채움재 강성, 말뚝 선단 채움재 높이, 기반암층 종류 변화에 따른 영향을 분석하였다. 또한 해석결과를 말뚝 설계 실무에서 주로 사용하는 선단 지지력 평가식과 비교하여 합성말뚝에 대한 기존 강관말뚝 지지력 산정식의 활용 가능성을 검토하였다.

Large-scale pilot test study on bearing capacity of sea-crossing bridge main pier pile foundations

  • Zhang, Xuefeng;Li, Qingning;Ma, Ye;Zhang, Xiaojiang;Yang, Shizhao
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.201-212
    • /
    • 2014
  • Due to the sea-crossing bridge span is generally large and main pier pile foundations are located in deep water and carry large vertical load, sea-crossing bridge main pier pile foundations bearing mechanism and load deformation characteristics are still vague. Authors studied the vertical bearing properties of sea-crossing bridge main pier pile foundations through pilot load tests. Large tonnage load test of Qingdao Bay Bridge main pier pile program is designed by using per-stressed technique to optimize the design of anchor pile reaction beam system. Test results show that the design is feasible and effective. This method can directly test bearing capacity of main pier pile foundations, and analysis bearing behaviors from test results of sensors which embedded in the pile. Through test study the vertical bearing properties of main pier pile foundation and compared with the generally short pile, author summarized the main pier pile foundations vertical bearing capacity and the main problem of design and construction which need to pay attention, and provide a reliable basis and experience for sea-crossing bridge main pier pile foundations design and construction.

PAR에 의한 강관 말뚝의 극한 수직 및 수평 지지력 예측 (Prediction on Ultimate Vertical and Horizontal Bearing Capacity of Steel Pipe Piles by Means of PAR)

  • 최용규
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.13-24
    • /
    • 1997
  • 말뚝 해석 프로그램인 PAR에 의하여 말뚝의 극한 수직 및 수평 지지력을 예측할 수 있는 방법을 제안하였으며,현장에서 수행된 말뚝재하시험 결과들을 이용하여 PAR에 의한 사례연구를 수행하였다. PAR에 의해 해석된 말뚝의 극한지지력은 정재하시험에서 구한 지지력에 대하여 약 15%이내의 오차범위에 들었다. 또한, 강관말뚝들에 수행된 정재하시헙, 정.동재하시험 그리고 PDA 결과들을 비교하였으며, PAR에 의해 극한지지력을 예측하였다. PAR을 이용하면 말뚝의 축방향 하중의 분포를 예측할 수 있었으며, 여기서, 하중전이해석도 근사적으로 수행할 수 있었다.

  • PDF

점토지반에 타입된 콘크리트 말뚝의 인발저항 및 크리프 거동 (Uplift Capacity and Creep Behavior of Concrete Pile Driven in Clay)

  • 신은철;김종인;박정준;이학주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.371-378
    • /
    • 2001
  • The working load at pile is sometimes subjected to not only compression load but also lateral load and uplift forces. Pile foundation is essential and uplift load can be applied because of buoyancy, a typhoon, wind or seismic forces. This study was carried out to determine the uplift capacity of concrete pile foundation driven in clay. Pile was driven in clay, between pile and clay adhesion factor was estimated, and it is the mean value between the cast-in-situ-pile and steel pipe pile. When pile foundation is loaded for long time, creep behavior occurs. The behavior of creep is originated from the clay creep contacted with pile. The creep behavior of pile foundation embedded in clay is heavily depended on the thickness of clay around the pile shaft, pore water pressure in clay, and creep behavior of clay.

  • PDF