• Title/Summary/Keyword: Physiological study

Search Result 7,208, Processing Time 0.043 seconds

The ecological response of the climate change indicator species, Korean fir (Abies koreana E. H. Wilson) (기후변화 지표종 구상나무(Abies koreana E. H. Wilson)의 생태학적 반응)

  • Yoon Seo Kim;Se Hee Kim;Jung Min Lee;Ji Won Park;Yeo Bin Park;Jae Hoon Park;Eui Joo Kim;Kyeong Mi Cho;Yoon Kyung Choi;Ji Hyun Seo;Joo Hyun Seo;Gyu Ri Kim;Ju Seon Lee;Do Hun Ryu;Min Sun Kim;Young Han You
    • Journal of Wetlands Research
    • /
    • v.26 no.1
    • /
    • pp.62-71
    • /
    • 2024
  • To assess the ecological changes of Korean fir (Abies koreana E. H. Wilson) under climate change conditions, growth and physiological responses were analyzed over a 5-year period in a control group (outdoors) and in a treatment group where the temperature and CO2 levels were elevated to closely resemble RCP 4.5 conditions. The results showed an increasing trend in annual branch length of A.koreana in the climate change treatment group over time. While climate change conditions did not significantly impact the morphological differences of A.koreana leaves, they did influence the biomass of the leaves, suggesting that as climate change progresses, the productivity of A.koreana leaves may decline. On the other hand, the chlorophyll content in A.koreana under climate change conditions was higher in the climate change treatment group, whereas the photosynthesis rate, transpiration rate, water use efficiency and stomatal conductance was higher in the control group. This suggests that an environment with elevated temperature and CO2 could influence an increase in stomatal density, but having a negative impact on photosynthetic reactions. Further research on stomatal density under each environmental treatment will be required to confirm this hypothesis. Additionally, as this study only observed changes in leaf biomass, further empirical research should be considered to understand the changes in biomass of A.koreana under climate change conditions. In conclusion, the environmental adaptability of A.koreana is expected to weaken in the long term under elevated temperatures and CO2.

Selection and appropriate culture conditions of antagonistic bacterium Bacillus altitudinis HC7 against button mushroom cobweb disease caused by Cladobotryum mycophilum (양송이버섯 솜털곰팡이병균(Cladobotryum mycophilum)에 대한 길항미생물 Bacillus altitudinis HC7의 선발 및 적정 배양조건)

  • Chan-Jung Lee;Hye-Sung Park;Seong-Yeon Jo;Gi-Hong An;Ja-Yun Kim;Kang-Hyo Lee
    • Journal of Mushroom
    • /
    • v.22 no.2
    • /
    • pp.60-66
    • /
    • 2024
  • This study was conducted to selection and investigate appropriate conditions for mass production of antagonistic microbes to control cobweb disease caused by Cladobotryum mycophilum. A grampositive bacterium was isolated from spent substrate of Agaricus bisporus and showed significant antagonistic activity against Cladobotryum mycophilum. The bacterium was identified as Bacillus altitudinis. based on the cultural, biochemical and physiological characteristics, and 16S rRNA sequence. The isolate is saprophytic, but not parasitic nor pathogenic to cultivated mushroom whereas it showed strong inhibitory effects against C. mycophilum cells in vitro. The control efficacy of B. altitudinis HC7 against cobweb disease of C. mycophilum was up to 78.2% on Agaricus bisporus. The suppressive bacterium may be useful for the development of biocontrol system. To define the appropriate conditions for the mass production of the Bacillus altitudinis HC7, we have investigated appropriate culture conditions and effects of various nutrient source on the bacterial growth. The appropriate initial pH and temperature were determined as pH 6.0 and 30℃, respectively. The appropriate concentration of medium elements for the growth of pathogen inhibitor bacterium(Bacillus altitudinis HC7) was determined as follows: 3.0% soluble startch, 10% soytone, 1.0% (NH4)2HPO4, 1.0 mmol KCl, and 0.5% L-asparagine.

Quality characteristics of different parts of garlic sprouts produced by smart farms during growth (스마트팜 생산 새싹마늘의 부위별 및 생육 기간에 따른 품질 특성)

  • Yu-Ri Choi;Su-Hwan Kim;Chae-Mi Lee;Dong-Hun Lee;Chae-Yun Lee;Hyeong-Woo Jo;Jae-Hee Jeong;Imkyung Oh;Ho-Kyung Ha;Jungsil Kim;Chang-Ki Huh
    • Food Science and Preservation
    • /
    • v.30 no.2
    • /
    • pp.272-286
    • /
    • 2023
  • Garlic sprouts can provide data on functional and food processing materials. This study compared the leaves, bulbs, and roots of garlic sprouts grown on smart farms during two growth periods (20 and 25 days). In addition, data for garlic bulbs grown in open fields were presented as reference materials. All garlic sprouts' total free sugar content decreased as the growth period increased. All plant parts' total organic acid content decreased as the growth period progressed, except for the root section. Potassium, phosphorus, and sulfur content increased during growth in all parts of the garlic sprouts. Alliin content decreased in all parts of the plant over time, whereas thiosulfinate content increased in the roots but decreased in the leaves and bulbs. Total polyphenol content increased in all parts of the plant during the growth period, except for the bulb, whereas the flavonoid content did not change significantly over time. The 2,2-diphenyl-1-picrylhydrazy (DPPH) and 2,2'-azinobis (3-ethylben-zothiazoline 6-sulfonate) (ABTS) free radical scavenging activities, as well as the superoxide dismutase (SOD)-like activity of garlic sprouts were 37.45-65.47%, 59.12-89.81%, and 89.52-98.59%, respectively. These activities tend to decrease during the growth period. Here, we showed that garlic sprouts have higher levels of functional substances and physiological activities than general garlic sprouts. It was also determined that a growth period of 20 days was suitable for garlic sprouts. Data for research on functional and food-processing materials can be obtained by analyzing garlic sprouts produced by smart farms.

Nutritional and functional constituents and antioxidant activity in whole onion (Allium cepa L.) by growth stage (생육시기별 양파 전초의 영양 및 기능성 성분과 항산화 활성 비교)

  • Sun-Kyung Lee;You-Seok Lee;Soo-Hyun Ji;Pyo-Hyeon Kim;Ju-Hyun Kim;Seong-Jun Kim;Kyung-Cheol Ma;Jin-Woo Lee
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.833-846
    • /
    • 2023
  • Onions are essential vegetables for Koreans' diet and have various physiological activities. However, problems arise every year due to the imbalance between production and demand. Therefore, in this study, nutritional and functional components, and antioxidant activity were analyzed for each growth period in order to utilize onions at the disposal period. Whole onions harvested before June showed higher values of general ingredients, inorganic ingredients, organic acids, spiraeoside, quercetin, total chlorophyll, and antioxidant activity than bulbs harvested in June. On the other hand, the free sugar content was higher in the bulb of the harvest season in June than in whole onions. The total thiosulfinate content was similar to that of whole onions and bulbs in the early stages of growth. In addition, as a result of comparing the flavonoid compound and antioxidant activity of each onion variety, whole onions harvested at 25 weeks were higher in content than onion bulbs harvested in June. In conclusion, onions before the harvest season in June had excellent utilization value as food. Harvesting before 21 weeks is desirable for growing onions with excellent nutritional value, while harvesting after 23 weeks is recommended for excellent functional components and antioxidant activity in onions.

Comparison of the physicochemical properties of native and cultivated Artemisia fukudo Makino (자생 및 재배 큰비쑥의 이화학적 특성 비교)

  • Bo Ra Kang;Eun Hee Kim;Yeon Kyoung Kim;Ah Hhyun Kim;Gyu Yeon Oh;Yoo Min Park;Ah Hyeon Jo;Hwan Sik Na;Mi Yeong Shin;Yang Joon An;Jeong Yong Cho;So Hyeon Lee
    • Food Science and Preservation
    • /
    • v.31 no.2
    • /
    • pp.267-275
    • /
    • 2024
  • Artemisia fukudo Makino belongs to the Asteraceae family, is a halophyte that can grow in salinity soils and is known for its various physiological activities. However, few studies were comparing it according to the growth environment. Therefore, in this study, we analyzed the antioxidant activity, functional ingredients, and safety of Artemisia fukudo Makino according to the growth environment. Total polyphenol content was the highest in native mature leaves, but 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) and 1,1-diphenyl-2-picrylhydrazyl radical scavenging activity was higher in cultivated leaves than in native leaves. The total mineral content, excluding sodium, was higher in cultivated than in native leaves. The content of potassium and calcium was higher in cultivated leaves than in native leaves. In addition, heavy metal analysis showed that cultivated leaves were generally lower than those of native leaves. Residual pesticides were not detected in all samples. In conclusion, since there is no significant difference in cultivated leaves compared to native leaves, it was judged that cultivated leaves could be used as a variety to be grown and mass-produced.

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Anatomical Variations in the Communicating Rami of the Upper Thoracic Sympathetic Ganglia Related to the Essential Palmar Hyperhidrosis (본태성 수부 다한증에 관련된 상부 흉부교감신경절 교통가지의 해부학적 변이)

  • Cho, Hyun-Min;Kim, Kil-Dong;Lee, Sak;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.182-188
    • /
    • 2003
  • Background: Although ramicotomy (division of the rami communicantes of the thoracic sympathetic ganglia) is a selective and physiological surgical method for essential hyperhidrosis, it has some problems such as higher recurrence rates and the different surgical results among the patients and between left and right sides in the same individual. As one of the factors that are related to the differences in surgical result and recurrences, we investigated the anatomical variations of the rami communicantes. The purpose of this study is to help develop new surgical methods to decrease surgical differences among the patients or between the left and right sides of the same individual and recurrence rates in the clinical application of ramicotomy. Material and Method: We dissected 118 thoracic sympathetic chains in 59 adult Korean cadavers (male: 33, female: 26) to examine the anatomical variations of the rami communicantes from the second to the fourth thoracic sympathetic ganglia that have major components innervating to the hands. After the dissection of bilateral thoracic sympathetic chains, we compared the anatomy of left and right sides and examined the anatomical variations of rami communicantes. Result: The number and variation of communicating rami connecting the spinal nerves and the second sympathetic thoracic ganglion were much larger than lower levels. There was considerably less variability in the anatomy of the rami communicantes at successive levels. Among the 59 cadavers dissected, only 14.3% (9/59) had similar anatomy of thoracic sympathetic chains at both sides. As the components related to the essential palmar hyperhidrosis, intrathoracic nerve of Kuntz from the second thoracic sympathetic ganglion to the first intercostal nerve or brachial plexus were observed in 55.9% (66/118). The incidence of descending rami communicates from the second thoracic sympathetic ganglion to the third intercostal nerve and from the third thoracic sympathetic ganglion to the fourth intercostal nerve were 49.2% (58/118) and 28.0% (33/118). And the incidence of ascending rami communicates from the third thoracic sympathetic ganglion to the second intercostal nerve and from the fourth thoracic sympathetic ganglion to the third intercostal nerve were 6.8% (8/118) and 3.4% (4/118), respectively. Conclusion: Based on the various anatomical evidences of the rami communicantes from this study, only the ramicotomy at the third sympathetic ganglion level is insufficient for the treatment of the essential palmar hyperhidrosis to decrease the difference of surgical results and recurrences. When one is planning to perform the ramicotomy for the essential palmar hyperhidrosis, it is advantageous to divide the intrathoracic nerve of Kuntz on the second rib and the descending or ascending rami communicantes on the third and the fourth ribs as well as all the communicating rami from the third sympathetic ganglion.

Psychophysiological Characteristics of Insomnia Patients Measured by Biofeedback System (바이오피드백을 이용하여 측정한 불면증 환자의 정신생리적 특징)

  • Huh, Sung-Young;Lee, Jin-Seong;Kim, Sung-Gon;Kim, Ji-Hoon;Jung, Woo-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.2
    • /
    • pp.70-76
    • /
    • 2015
  • Background and Objectives: Insomnia is the most prevalent sleep disorder in the general population and is considered to be a disorder of hyperarousal. The aim of this study was to measure the psychophysiological responses in insomnia patients using a biofeedback system, and to compare them with results from normal healthy subjects. Materials and Methods: Eighty patients with primary insomnia (35 males and 45 females, average age $49.71{\pm}12.91years$) and 101 normal healthy controls (64 males and 37 females, average age $27.65{\pm}2.77$) participated in this study. Electromyography (EMG), heart rate (HR), skin conductance (SC), skin temperature (ST), and respiratory rate (RR) were recorded using a biofeedback system during 5 phases (baseline, stress 1, recovery 1, stress 2, recovery 2) of a stress reactivity test, and average values were calculated. Difference in values between the two groups in each corresponding phase was analyzed with independent t-test, and change in values across phases of the stress reactivity test was analyzed with paired t-test (all two-tailed, p<0.05). Results: Compared to normal controls, insomnia patients had higher EMG in all 5 phases (baseline : $7.72{\pm}3.88{\mu}V$ vs. $4.89{\pm}1.73{\mu}V$, t = -6.06, p<0.001 ; stress 1 : $10.29{\pm}5.16{\mu}V$ vs. $6.63{\pm}2.48{\mu}V$, t = -5.84, p<0.001 ; recovery 1 : $7.87{\pm}3.86{\mu}V$ vs. $5.17{\pm}2.17{\mu}V$, t = -5.61, p<0.001 ; stress 2 : $10.22{\pm}6.07{\mu}V$ vs. $6.98{\pm}2.98{\mu}V$, t = -4.37, p<0.001 ; recovery 2 : $7.88{\pm}4.25{\mu}V$ vs. $5.17{\pm}1.99{\mu}V$, t = -5.27, p<0.001). Change in heart rate across phases of the stress reactivity test were higher in normal controls than in insomnia patients (stress 1-baseline : $6.48{\pm}0.59$ vs. $3.77{\pm}0.59$, t = 3.22, p = 0.002 ; recovery 1- stress 1 : $-5.36{\pm}0.0.59$ vs. $-3.16{\pm}0.47$, t = 2.91, p = 0.004 ; stress 2-recovery 1 : $8.45{\pm}0.61$ vs. $4.03{\pm}0.47$, t = 5.72, p<0.001 ; recovery 2-stress 2 : $-8.56{\pm}0.65$ vs. $4.02{\pm}0.51$, t = -5.31, p<0.001). Conclusion: Psychophysiological profiles of insomnia patients in a stress reactivity test were different from those of normal healthy controls. These results suggest that the sympathetic nervous system is more highly activated in insomnia patients.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF