• Title/Summary/Keyword: Physiological Sensor

Search Result 127, Processing Time 0.029 seconds

Improvement of conception rate on Hanwoo; The key hormones and novel estrus detector

  • Joo, Young Ho;Jeong, Seung Min;Paradhipta, Dimas Hand Vidya;Lee, Hyuk Jun;Lee, Seong Shin;Choi, Jeong Seok;Noh, Hyeon Tak;Chang, Hong Hee;Kim, Eun Joong;Kim, Sam Churl
    • Journal of Animal Science and Technology
    • /
    • v.63 no.6
    • /
    • pp.1265-1274
    • /
    • 2021
  • Two field experiments were conducted to improve the conception rate of Hanwoo cow. The first experiment aimed to investigate the physiological condition of Hanwoo cows on estrus, including metabolic profiles and body condition score (BCS). The second experiment investigated the effect of a novel estrus detector on the artificial insemination (AI) conception rate for Hanwoo cows. For the first experiment, 80 Hanwoo cows (2.5 ± 0.10 of parity), approximately one month before estrus, were housed in 16 pens and offered the experimental diets twice daily with free water access. The BCS were recorded, and blood was collected from the jugular veins just before AI. The collected blood was used to measure physiological conditions, such as metabolite and hormone levels. For the second experiment, each cow was equipped with a neck-mounted estrus detector collar, which had a sensor connected through the internet. Approximately one month before estrus, three hundred sixty Hanwoo cows (2.4 ± 0.21 of parity) were assigned into groups with or without W-Tag collar treatments. The animals were managed the same as in the first experiment. The pregnancy rate reached 55% in the first experiment. The concentration of luteinizing hormone (LH) was higher (p < 0.012; 1.56 vs. 1.08 ng/mL) in cows that were not pregnant (NPG) than in cows that were pregnant (PG) after AI. The BCS and other concentrations of metabolites and hormones in the blood were not different in both NPG and PG cows. The ranges of estrogen, LH, and follicle-stimulating hormone for PG cows were 11.9 to 39.0 pg/mL, < 0.25 to 1.98 ng/mL, and < 0.50 to 0.82 ng/mL, respectively. In the second experiment, cows with the estrus detector had lower days open (p < 0.001; 78.1 vs. 84.8 d), insemination frequency (p < 0.001; 1.26 vs. 2.52), and return of estrus (p < 0.001; 70.9 vs. 79.1 d) than those in cows without the estrus detector. In conclusion, the present study indicated that lower LH concentration just before AI potentially increased the pregnancy rate of Hanwoo cows. Furthermore, the application of estrus detectors to Hanwoo cows could improve the conception success rate for AI.

Carbon Metabolism and Its Global Regulation in Corynebacterium glutamicum (Corynebacterium glutamicum의 탄소대사 및 총체적 탄소대사 조절)

  • Lee, Jung-Kee
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.349-361
    • /
    • 2010
  • In this review, the current knowledge of the carbon metabolism and global carbon regulation in Corynebacterium glutamicum are summarized. C. gluamicum has phosphotransferase system (PTS) for the utilization of sucrose, glucose, and fructose. C. glutamicum does not show any preference for glucose when various sugars or organic acids are present with glucose, and thus cometabolizes glucose with other sugars or organic acids. The molecular mechanism of global carbon regulation such as carbon catabolite repression (CCR) in C. glutamicum is quite different to that in Gram-negative or low-GC Gram-positive bacteria. GlxR (glyoxylate bypass regulator) in C. glutamicum is the cyclic AMP receptor protein (CRP) homologue of E. coli. GlxR has been reported to regulate genes involved in not only glyoxylate bypass, but also central carbon metabolism and CCR including glycolysis, gluconeogenesis, and tricarboxylic acid (TCA) cycle. Therefore, GlxR has been suggested as a global transcriptional regulator for the regulation of diverse physiological processes as well as carbon metabolism. Adenylate cyclase of C. glutamicum is a membrane protein belonging to class III adenylate cyclases, thus it could possibly be a sensor for some external signal, thereby modulating cAMP level in response to environmental stimuli. In addition to GlxR, three additional transcriptional regulators like RamB, RamA, and SugR are also involved in regulating the expression of many genes of carbon metabolism. Finally, recent approaches for constructing new pathways for the utilization of new carbon sources, and strategies for enhancing amino acid production through genetic modification of carbon metabolism or regulatory network are described.

Crop Monitoring Technique Using Spectral Reflectance Sensor Data and Standard Growth Information (지상 고정형 작물 원격탐사 센서 자료와 표준 생육정보를 융합한 작물 모니터링 기법)

  • Kim, Hyunki;Moon, Hyun-Dong;Ryu, Jae-Hyun;Kwon, Dong-Won;Baek, Jae-Kyeong;Seo, Myung-Chul;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1199-1206
    • /
    • 2021
  • Accordingly, attention is also being paid to the agricultural use of remote sensing technique that non-destructively and continuously detects the growth and physiological status of crops. However, when remote sensing techniques are used for crop monitoring, it is possible to continuously monitor the abnormality of crops in real time. For this, standard growth information of crops is required and relative growth considering the cultivation environment must be identified. With the relationship between GDD (Growing Degree Days), which is the cumulative temperature related to crop growth obtained from ideal cultivation management, and the vegetation index as standard growth information, compared with the vegetation index observed with the spectralreflectance sensor(SRSNDVI & SRSPRI) in each rice paddy treated with standard cultivation management and non-fertilized, it was quantitatively identified as a time series. In the future, it is necessary to accumulate a database targeting various climatic conditions and varieties in the standard cultivation management area to establish a more reliable standard growth information.

Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis (맥진기술동향 조사를 통한 맥진기 개발방안 제안)

  • Lee, Yu-Jung;Lee, Jean;Kim, Jang-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

Silicone Rubber Membrane-Based Chloride Ion-Selective Electrode (실리콘러버-지지체 염화이온선택성 막전극)

  • Sakong, Dong-Sik;Kim, Jin-Mog;Cha, Jin-Mog
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.12
    • /
    • pp.653-660
    • /
    • 1997
  • Silicone rubber-matrix membranes doped with tetradecyltrimethylammonium chloride (TDTMACl) are used to enhance electrode performance for chloride measurements in physiological samples. The optimized membrane formulation incorporates 95.4 wt% silicone rubber and 4.6 wt% TDTMACl, and its pH response is negligible in the range of pH 6-10. The TDTMACl-doped silicone rubber membrane exhibits sub-Nernstian response to chloride from 10 to 300 mM (-37.5 mV/decade), but its selectivities for chloride over other anions are remarkably enhanced: KpotCl,NO3=1.3, KpotCl,I=2.0, KpotCl,Sal=0.8, KpotCl,SCN=2.0 and KpotCl,ClO4=0.8. Furthermore, since the silicone rubber-matrix membrane exhibits better adhesion to the solid surface than do PVC membranes, the lifetime of the coated-wire type membrane electrode is greatly improved. The response properties toward chloride and salicylate for solid-state sensor are not significantly changed after at least 35 days of use.

  • PDF

A Structured Growth Model of Scutellaria baicalensis G. Plant Cell (Scutellaria baicalensis G. 식물 세포의 구조적 성장 모델)

  • 최정우;조진만;이정건;이원홍;김익환;박영훈
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.251-258
    • /
    • 1998
  • A structured kinetic model is proposed to describe cell growth and secondary metabolite, flavone glycosides, synthesis in batch suspension culture of Scutellaria baicalensis G. The model has been developed by representing the physiological state of cell described as the activity and viability which can be estimated based on the culture fluorescence. In the model, three type of cells are considered; active-viable, nonactive-viable and dead cells. Viable cell weight could be determined based on the relative fluorescence intensity. The flavone glycosides could be produced by both active-viable and non-active viable cells with a different production rate. And the model includes the cell expansion due to glucose concentration and death phase which accounts for the release of intracellular secondary metabolite into medium. Dependent variables include substrate concentration(glucose), cell mass(dry cell weight and fresh cell weight), product concentration(flavone glycosides), activity and viability. Satisfactory agreement between the model and experimental data is obtained from shake flask culture of Scutellaria baicalensis G. The proposed model can predict the cell growth and flavone glycosides synthesis as well as intermediate materials.

  • PDF

Analysis of the Assist Characteristics for Torque of the Ankle Plantarflexion in Elderly Adults Wearing the Ankle-Foot Orthosis (족관절 보조기를 착용한 고령자의 족관절 족저굴곡 토크 보조특성 분석)

  • Kim, Kyung;Kang, Seung-Rok;Piao, Yong-Jun;Jeong, Gu-Young;Kwon, Tae-Kyu
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Ankle-foot orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of ankle muscular activities was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find a effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject's soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feedback control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feedback control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feedback control wearing it and with feedback control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feedback control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feedback control was increased. The amount of a increasing with feedback control is more higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feedback control.

Wrist Wearable Device for the Measurement and Analysis of Physiological Signals (생체신호 측정 및 분석을 위한 손목 착용형 단말기)

  • Im, Jae Joong;Li, Ming Kui;Hwang, Chan Song
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.65-73
    • /
    • 2012
  • Wrist wearable device for the measurement of pulse rate, ECG, and activity during normal daily life, which could be used for the continuous monitoring and remote transmission of acquired data, was developed. Pressure sensor, device attached electrodes, and 3-degree accelerometer were used. Analysis algorithm and firmware program were established for providing diagnostic information for the users. Results of this study, possible for the management of health report and transmission of the results through bluetooth by wearing simple personal wrist device, could be used for the development of portable device in the u-healthcare environment.

Heart Response Effect by 1/f Fluctuation Sounds for Emotional Labor on Employee (1/f 수준 별 음악 자극이 감정 노동 종사자의 심장 반응에 미치는 효과)

  • Jeon, Byung-Mu;Whang, Min-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.18 no.3
    • /
    • pp.63-70
    • /
    • 2015
  • This study identified heart response of participants while listening to sounds which have 1/f fluctuations with exponent ${\alpha}$ gradient. The participants were engaged in emotional stress work. Prior studies related to 1/f fluctuation sound have reported that sound source can alleviate psychological and physiological state of users. Subjects of this study were exposed to sound with three levels of ${\alpha}$ gradient. Heart response of subjects were measured with Photoplethysmography(PPG) sensor simultaneously. The dependent variables of this study were beat per minute(BPM), very low frequency percent of pulse rate variability (VLF percent), the standard deviation of all normal RR intervals (SDNN), and high frequency power(HF power). Subject showed arousal response when exposed to sound with exponent ${\alpha}$ gradient of 3 whereas the sound with exponent ${\alpha}$ gradient of 1 and 2 resulted in relax effect. The characteristic of 1/f fluctuation sounds can be applied to alleviate stress for employers under emotional labor.

Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot (압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구)

  • Lee Si-Woo;Lee Yu-Jung;Lee Hae-Jung;Kang Hee-Jung;Kim Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).