• Title/Summary/Keyword: Physiological Sensor

Search Result 127, Processing Time 0.033 seconds

Design and Implementation of a Mobile Ubiquitous Healthcare System (모바일 유비쿼터스 헬스케어시스템 설계 및 구현)

  • Lee, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.781-793
    • /
    • 2010
  • Recently, owing to the development of ubiquitous sensor network and mobile communication technologies, many studies on healthcare system are being carried out. In this paper, we have designed and implemented a mobile u-Healthcare system based on sensor network. The u-Healthcare system is composed of three components: wireless sensor network at home, healthcare center located at remote site, and gateway which relays sensing physiological signals to healthcare center. In order to measure patient's physiological signal three sensors are used: three channel ECG sensor, pulse oximeter, and blood pressure sensor. Each sensor is mounted on a mote which can send gathered signal to the base node using Zigbee communication protocol. Once the base node receives physiological signal from each sensor, the client in the base node transfers the signal to the healthcare center. The received physiological signal at the healthcare center is analyzed and processed using various algorithms. The processed results are compared to the standard healthcare database and appropriate treatment including dietetics and exercise cure would be sent to the patient as feedback using SMS message or healthcare center web site. Each patient can check and manage one's health state every day using the healthcare system and gain a recovery under the treatments from minor health problems.

Cryptanalysis of an 'Efficient-Strong Authentiction Protocol (E-SAP) for Healthcare Applications Using Wireless Medical Sensor Networks'

  • Khan, Muhammad Khurram;Kumari, Saru;Singh, Pitam
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.5
    • /
    • pp.967-979
    • /
    • 2013
  • Now a day, Wireless Sensor Networks (WSNs) are being widely used in different areas one of which is healthcare services. A wireless medical sensor network senses patient's vital physiological signs through medical sensor-nodes deployed on patient's body area; and transmits these signals to devices of registered medical professionals. These sensor-nodes have low computational power and limited storage capacity. Moreover, the wireless nature of technology attracts malicious minds. Thus, proper user authentication is a prime concern before granting access to patient's sensitive and private data. Recently, P. Kumar et al. claimed to propose a strong authentication protocol for healthcare using Wireless Medical Sensor Networks (WMSN). However, we find that P. Kumar et al.'s scheme is flawed with a number of security pitfalls. Information stored inside smart card, if extracted, is enough to deceive a valid user. Adversary can not only access patient's physiological data on behalf of a valid user without knowing actual password, can also send fake/irrelevant information about patient by playing role of medical sensor-node. Besides, adversary can guess a user's password and is able to compute the session key shared between user and medical sensor-nodes. Thus, the scheme looses message confidentiality. Additionally, the scheme fails to resist insider attack and lacks user anonymity.

Mobile u-healthcare system in IEEE 802.15.4 WSN and CDMA network environments

  • Toh, Sing-Hui;Lee, Seung-Chul;Lee, Hoon-Jae;Do, Kyeong-Hoon;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.337-342
    • /
    • 2009
  • This paper describes a robust mobile u-healthcare system with multiple physiological signs measurement capability in real time with integration of WSN(wireless sensor network) technology and CDMA(code division multiple access) network. A cellular phone receives health data in WSN and performs local physiological signs analysis at a phone processor, and then transmits abnormal data to server for further detail or precise health signal evaluation by a medical doctor over a CDMA network. Physiological signs of the patients are continuously monitored, processed and analyzed locally at cellular phone process to produce useful medical information for diagnosis and tracking purposes. By local simple analysis in cellular phone processor we can save the data transmission cost in CDMA network. By using the developed integrate ubiquitous healthcare service architecture, patients can realize self-health checking so that the prevention actions can be taken earlier. Appropriate self-monitoring and self-management can cure disease and relieve pain especially for patients who suffer from chronic diseases that need long term observation.

Emotion Recognition using Short-Term Multi-Physiological Signals

  • Kang, Tae-Koo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.3
    • /
    • pp.1076-1094
    • /
    • 2022
  • Technology for emotion recognition is an essential part of human personality analysis. To define human personality characteristics, the existing method used the survey method. However, there are many cases where communication cannot make without considering emotions. Hence, emotional recognition technology is an essential element for communication but has also been adopted in many other fields. A person's emotions are revealed in various ways, typically including facial, speech, and biometric responses. Therefore, various methods can recognize emotions, e.g., images, voice signals, and physiological signals. Physiological signals are measured with biological sensors and analyzed to identify emotions. This study employed two sensor types. First, the existing method, the binary arousal-valence method, was subdivided into four levels to classify emotions in more detail. Then, based on the current techniques classified as High/Low, the model was further subdivided into multi-levels. Finally, signal characteristics were extracted using a 1-D Convolution Neural Network (CNN) and classified sixteen feelings. Although CNN was used to learn images in 2D, sensor data in 1D was used as the input in this paper. Finally, the proposed emotional recognition system was evaluated by measuring actual sensors.

A Multi-purpose Fingerprint Readout Circuit Embedding Physiological Signal Detection

  • Eom, Won-Jin;Kim, Sung-Woo;Park, Kyeonghwan;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.793-799
    • /
    • 2016
  • A multi-purpose sensor interface that provides dual-mode operation of fingerprint sensing and physiological signal detection is presented. The dual-mode sensing capability is achieved by utilizing inter-pixel shielding patterns as capacitive amplifier's input electrodes. A prototype readout circuit including a fingerprint panel for feasibility verification was fabricated in a $0.18{\mu}m$ CMOS process. A single-channel readout circuit was implemented and multiplexed to scan two-dimensional fingerprint pixels, where adaptive calibration capability against pixel-capacitance variations was also implemented. Feasibility of the proposed multi-purpose interface was experimentally verified keeping low-power consumption less than 1.9 mW under a 3.3 V supply.

Measuring the effects of estrus on rumen temperature and environment, behavior and physiological attributes in Korean Native breeding cattle

  • Jae-Young Kim;Jae-Sung Lee;Yong-Ho Jo;Hong-Gu Lee
    • Journal of Animal Science and Technology
    • /
    • v.65 no.3
    • /
    • pp.579-587
    • /
    • 2023
  • In this study, rumen temperature and environment in estral and non-estral Korean Native breeding cattle were evaluated by using a bolus sensor. Behavioral and physiological changes in study animals were also assessed. To assess the rumen temperature and environment, we inserted bolus sensors into 12 Korean Native cattle with an average age of 35.5 months, then measured temperature and activity within the rumen using the wireless bolus sensor. Drinking, feeding and mounting behavior, and measured vaginal temperature and levels of intravaginal mucus resistance were recorded. We found that cattle in estrus exhibited more acts of mounting (37.4 vs. 0 times/day), increased vaginal temperature (39.0℃ vs. 38.4℃), and decreased vaginal mucus resistance (136.3 Ω vs 197.4 Ω), compared with non-estral animals. Furthermore, increased levels of rumen activity were most significant in estrus cattle at the highest activity levels (p < 0.01). Overall, the estrus group exhibited increased rumen temperature (p = 0.01), compared with the non-estrus group. In conclusion, the results of this study not only provide basic physiological data related to estrus in improved Korean Native breeding cattle, but also suggest that monitoring of rumen temperature and activity might be used as an effective smart device for estrus detection.

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Nam, Jae-Hyun;Chang, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.67-71
    • /
    • 2007
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, Sp02, and heart rate.

  • PDF

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Chang, Yong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1401-1407
    • /
    • 2008
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, SpO2, and heart rate.

Development of Bio-sensor-Based Feature Extraction and Emotion Recognition Model (바이오센서 기반 특징 추출 기법 및 감정 인식 모델 개발)

  • Cho, Ye Ri;Pae, Dong Sung;Lee, Yun Kyu;Ahn, Woo Jin;Lim, Myo Taeg;Kang, Tae Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1496-1505
    • /
    • 2018
  • The technology of emotion recognition is necessary for human computer interaction communication. There are many cases where one cannot communicate without considering one's emotion. As such, emotional recognition technology is an essential element in the field of communication. n this regard, it is highly utilized in various fields. Various bio-sensor sensors are used for human emotional recognition and can be used to measure emotions. This paper proposes a system for recognizing human emotions using two physiological sensors. For emotional classification, two-dimensional Russell's emotional model was used, and a method of classification based on personality was proposed by extracting sensor-specific characteristics. In addition, the emotional model was divided into four emotions using the Support Vector Machine classification algorithm. Finally, the proposed emotional recognition system was evaluated through a practical experiment.

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.