• Title/Summary/Keyword: Physical wedge

Search Result 103, Processing Time 0.024 seconds

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

The Study of the Mid-sole Wedge of Pronated Group on Maximum Force and Foot Pressure (중족부 Wedge 착용 시 회내 집단의 최대 힘과 족저압력 연구)

  • Lee, Jae-Ik;Lee, Hyo-Taek;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.337-344
    • /
    • 2010
  • This study was conducted on male college students with pronated foot to measure the foot pressure by having them wear three kinds of mid-sole wedge ($0^{\circ}$, $5^{\circ}$, $10^{\circ}$). Maximum force, foot contact area, mean pressure and peak pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding maximum force, there were statistically significant difference in the area 3 of the middle foot(p<.05). Regarding the foot contact area, it appeared broad in the outside area(1, 3, 5) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Mean pressure by foot area decreased in the inside of the foot according to mid-sole wedge, and there was statistically significant difference in the area 2 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Regarding the peak pressure by foot area, the pressure roughly decreased in the inside area(2, 4, 7) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1(p<.05), 2(p<.05) of the rear foot and the area 3 of the middle foot(p<.05).

The Effect of Functional Electrical Stimulation on the Spastic Plantar Flexor in Stroke Patients (기능적 전기자극이 뇌졸중 환자의 족저굴곡근 강직에 미치는 영향)

  • Son, Young-Sik;Park, Rea-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.161-174
    • /
    • 2001
  • The purpose of this study was to reduce the spasticity of plantarflexion. the subjects of this study were 30 hemiplegic patients with stroke who received of physical therapy in JinJu o o hospital from May to July 2000. the subjects were divided into three groups(FES groups 10, FES + tilt table-wedge board standing groups 10, & tilt table-wedge board standing groups 10). The result were as follow 1. FES therapy was a effective method to reduce the spasticity of plantarflexor. there was a significant difference in modified Ashworth scale(p<.01). there was a significant difference in weight bearing ratio between nonparetic and paretic side(p<.01). 2. Tilt table-wedge board standing therapy was a effective method to reduce the spasticity of plantarflexor to a degree but there was a no significant difference in modified Ashworth scale(p<.05). there was a significant difference in weight bearing ratio between nonparetic and paretic side(p<.01). 3. Tilt table-wedge board standing therapy + FES therapy was a effective method to reduce the spasticity of plantarflexor. there was a significant difference in modified Ashworth scale(p<.01). there was a significant difference in weight bearing ratio between nonparetic and paretic side(p<.01) 4. There was a significant difference in weight bearing ratio between nonparetic and paretic side according to the grade spasticity(p<.01). 5. For normal persons vs hemiplegic patients, there was a significant different in weight bearing ratio between nonparetic and paretic side(experimental subjects 1 p<.01, experimental subjects 2 p<.01, control subjects p<.05).

  • PDF

Scattering by a Lossy Dielectric Wedge (손실 유전체 쐐기에 의한 산란)

  • 서종화;나정웅
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.227-230
    • /
    • 1999
  • Rigorous formulation for solving the scattered fields by a lossy dielectric wedge is proposed. By employing the Kirchhoff's integrals in the physical domain and the extinction theorem in the mathematically complementary region, it is shown that the accurate solution is obtained by adding the numerically corrected fields generated by the multipole source expansions to the analytically approximated physical optics solution. Its accuracy is affirmed by the extinction behavior of the solution in the complementary region.

  • PDF

Diffraction of Electromagnetic Waves by a Dielectric Wedge, Part III: Correction by Neumann-Expanded Source (쇄기형 유전체에 의한 전자파의 회절, III부: Neumann 전개된 전원에 의한 수정)

  • 김세윤;라정웅;신상영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.9
    • /
    • pp.1027-1038
    • /
    • 1988
  • This paper, the last part of these three companion papers treated the electromagnetic diffraction by a dielectric wedge, presents the correction to the physical optics approcomation by the sheet currents of the Neumann expansion. Those expansion coefficients obtained by solving dual series equation amenable to simple numerical calculation may provide the asymprotically corrected solution. The validity of this result, satisfying both the edge condition near the tip of the dielectric wedge and the boundary condition along dielectric interfaces, is assured by approach of the corrected diffraction pattern to that of a perfectly conducting wedge for large permittivity of dielectric wedge.

  • PDF

The effects of increased unilateral and bilateral calcaneal eversion on pelvic and trunk alignment in standing position

  • Yi, Jaehoon
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • Objective: Generally, it is known that there is a correlation between excessive calcaneus eversion and a patient with low back pain and it also affects pelvic alignment. However, there are not enough studies that show calcaneal eversion having an effect on the alignment of the trunk. Design: Cross-sectional study. Methods: A 3-dimensional motion analysis system was used to assess the lower limbs, pelvic alignment, and trunk alignment with increased unilateral and bilateral calcaneal eversion in twenty-one subjects. All subjects were asked to maintain a static posture for seven seconds on a wedge three times per posture for measurement and analysis purposes. The wedge used in the process was a lateral wedge with a 10-degree tilt to the lateral direction. To unify all of the subjects' foot position, the front and inner side of the wedge were marked. The height of the tilted wedge's inner side and flat wedge were balanced equally in order to be able to maintain the lateral part of the foot to the same height when producing an increased calcaneal eversion. Results: Comparing the changes in trunk and pelvic alignment in accordance to calcaneal eversion for each posture, there was a significant different in the X and Y-axis for each posture, but not in the Z-axis (p<0.05). Thus, it can be confirmed that calcaneal eversion in the sagittal plane and frontal plane may have and effect on the pelvis and the trunk. Conclusions: Postures with increased bilateral and unilateral calcaneal eversion has an effect on pelvic alignment, but does not cause any changes in trunk alignment.

Successive Iteration of Geometrical-Optics for Diffracted Fields (기하광학 반복적용에 의한 회절파 계산)

  • Hwang, Churl-Kew;Kim, Se-Yun;Ra, Jung-Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.41-55
    • /
    • 1989
  • Successive iteration of geometrical optics(GO)is suggested to calculate wedge diffraction fields. For a wedge and given source, the GO field may be obtained when the fields by the half spaces are found and the shadow regions are determined. Furthermore, one may caluculate the sources which are equivalent to the discontinuities of the GO field along the shadow boundaries and form a new wedge problem with the equivalent sources instead of the original one. It is shown that the field by the wedge and the equivalent sources equals to the diffraction field which GO requires for the complete solution. Also, it is shown that the field generated by the equivalent sources in the unbounded space, or the incident field in the new wedge problem, equls to the diffraction field approximated by the physical optics. The new wedge problem is solved here by another application of the GO to approximate the diffraction field and the result is compared with that by the physical optics. For a validity of the successive iteration of GO , infinite iteration of GO is performed analytically and the convergence is examined ofr conducting wedges, of which the exact solution is available.

  • PDF

The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$ (Digora$\textregistered$에서 정량영상의 특성에 대한 평가)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

Biomechanical Effect on Knee Adduction Moment by Lateral Wedge Insole in Transfemoral Amputee (외측웨지인솔이 대퇴절단자의 무릎내전모멘트에 미치는 영향)

  • Chang, Yun-Hee;Lee, Wan-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.239-244
    • /
    • 2012
  • The prevalence of knee osteoarthritis was higher people with lower limb amputation. This was identified that transfemoral amputees have a greater external knee adduction moment than ablebodied subjects by biomechanical studies. Therefore, they need rehabilitative intervention for prevention and reduction of knee osteoarthritis. The purpose of this study was to determine the effect of lateral wedge insole used in the treatment of knee osteoarthritis. This study was participated in fourteen unilateral transfemoral amputees and we were analyzed the difference gait variables between without lateral wedge insole and with $5^{\circ}$ and $10^{\circ}$ lateral wedge insole during gait. Our results showed that step length ratio was more symmetrical and, hip adduction and ankle inversion angle were more close to normal value, and knee adduction moment was decreased as the wedge angle increases. We proposed that these data would be utilized conservative treatment of knee osteoarthritis in lower limb amputees.

Effect of Medial Wedge on Muscle Activity of Lower Limb in Healthy Adults During One Leg Standing (한 다리 서기 시 내측 쐐기(wedge)의 적용이 하지 근활성도에 미치는 영향)

  • Hong, Ji-A;Kim, Min-Hee;Jung, Doh-Heon;Lim, One-Bin;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.18 no.2
    • /
    • pp.60-66
    • /
    • 2011
  • Foot posture is important in the development of the musculoskeletal structure in the lower limbs because it can change the mechanical alignment. Although foot orthotics are widely used for the correction of malalignments in the lower extremities, the biomechanical effects of wedges have not yet been cleared. The aim of this study was to investigate whether medial wedges affect the electromyographic (EMG) activity of the knee and hip joints in healthy adults that are performing one leg standing. Seventeen healthy volunteers performed the one leg standing under two foot conditions: A level surface, and a $15^{\circ}$ medial wedge. The subjects' EMG data for the gluteus maximus (Gmax), gluteus medius (Gmed), tensor fasciae latae (TFL), biceps femoris (BF), vastus lateralis (VL), and vastus medialis oblique (VMO) were recorded, along with the surface EMG, and all were analyzed. The EMG activity of the Gmed and TFL had significantly decreased under the medial wedge condition during one leg standing. Further study is needed in order to investigate whether medial wedges influence the EMG activity and kinematic data of the knee and hip joints as well as the ankle joints in adults with flexible flatfoot, while they are performing one leg standing.