• Title/Summary/Keyword: Physical protection system

Search Result 216, Processing Time 0.023 seconds

DSP-based Current Programmed Control of Three Phase PWM AC-AC Boost Converter (3상 PWM AC-AC 부스트 컨버터의 DSP 기반 전류 프로그램 제어)

  • Choi Nam-Sup;Li Yulong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. Compared to duty-ratio voltage control, current programmed control has several advantages such as reduction of system order, inherent current protection and robust output. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation and to establish some important characteristic equations for control purpose. The experiment results show the validity of the proposed scheme.

Ecological Risk Assessment based on Watershed System Assimilative Capacity in take Texoma, Texas-Oklahoma, USA (유역시스템 정화력을 고려한 생태위해성평가 사례연구: Lake Texoma Watershed (TX&OK, USA)를 대상으로)

  • An, Youn-Joo;Donald H. Kampbell;Guy W. Sewell
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.27-27
    • /
    • 2003
  • Lake Texoma is located on the border of southern Oklahoma and northern Texas. It has 93,000 surface acres, and is a focus of the recreation, and farming industries in the region. There are potential stressors around the Lake Texoma watershed that may cause adverse ecological effects in the lake. System assimilative capacity (SAC) is the ability of abiotic and biotic processes to atteuniate the stressors. SAC Exceeded indicates potential of occuring adverse eco-effects. A number of representative chemical release sites and stressor sources in the surrounding watershed were characterized, and several impact sites having stressors sources, such as being near agriculture, landfills, housing areas, oil production fields and heavy use recreational activity, were selected for surface water, sediment, and groundwater monitoring. A paired reference site, having similar physical characteristics as its impact site, was also chosen based on its proximity to the impact site. Lake water samples were collected at locations identified as marina entrance, gasoline filling station, and boat dock at five marinas selected on Lake Texoma from September 1999 to December 2001. Paired water and sediment samples were also collected. Groundwater samples were collected at about 70 producing monitoring wells. Water quality parameters measured were inorganics (nitrate, nitrite, orthophosphate, ammonia, sulfate, and chloride), dissolved methane, total organic carbon (TOC) (or DOC), volatile organic compounds (VOCs) such as methyl tert-butyl ether (MTBE) and BTEX, and a suite of metals. Biotic communities were evaluated at impact and reference sites. Five basic components were measured; two terrestirial components (plants and bird comminitires) and three aquatic components (benthic inverbrates, litteral-zone fishes, ecosystem attribures). Potential impacts to these comminites were evaluated.

  • PDF

The Correspondence Competence of Information Accident by Firms Experienced in Confidential Information Leak (기밀정보 유출 경험을 가진 기업들의 정보사고 대응역량 강화에 관한 연구)

  • Jung, Byoungho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.2
    • /
    • pp.73-86
    • /
    • 2016
  • The purpose of this study is to examine a security investment for firms experienced in confidential information leak. Information security is an apparatus for protection of secret information. The competence of information security is a competitiveness to avoid information leakage in changing business environment. The type of information security is divided into administrative security, technical security and physical security. It is necessary to improve the incident correspondence competence through information security investment of the three types. Therefore, the investment of information security is to enhance information-asset protection of firms. To reinforce accident response competence, an organization discussed an establishment, security technology development, expand investment and legal system of the security system. I have studied empirically targeting the only information leak of firms. This data is a technical security competence and technology leakage situation of firms happened in 2010. During recovery of the DDos virus damage on countries, company and individual, the collected data signify a reality of information security. The data also identify a security competence of firms worrying information security management. According to the study, the continuous investment of information security has a high competence of accident correspondence. In addition, the most of security accidents showed a copy and stealing of paper and computer files. Firm on appropriate security investment is an accident correspondence competence higher than no security investment regardless of a large, small and medium-sized, and venture firm. Furthermore, the rational security investment should choose the three security type consideration for firm size.

Simulation of Beta Ray Spectra in Liquid Scintillation Counting System by means of Monte Carlo Method (Monte Carlo 계산에 의한 액체섬광계수기의 베타선 스펙트럼 Simulation)

  • Yi, Chul-Young;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.17-25
    • /
    • 1993
  • Beta ray spectra of $^3H,\;^{14}C\;and\;^{36}Cl$ in liquid scintillation counting system have been calculated using the Monte Carlo method by which physical behaviors of particle transport in medium were simulated. The calculations have been carried out on the basis of beta rays being slowing down according to the continuous slowing down approximation(CSDA) model. Beta rays generated in simulation geometry were traced until they lost their energy below 0.3keV that in known to be the detection limit in the liquid scintillation counter. Scintillator solution in which pure beta emitting radionuclides were dissolved uniformly was assumed to be bottled in the shape of right circular cylinder with 12.5mm in radius and 35mm in height. The comparison of the calculated and measured results showed satisfactory agreement between those two, with slight discrepancy due to self quenching in the case of lower energy of emitted beta particles in the solution.

  • PDF

Study on Memory Data Encryption of Windows Hibernation File (윈도우 최대 절전 모드 파일의 메모리 데이터 암호화 기법 연구)

  • Lee, Kyoungho;Lee, Wooho;Noh, Bongnam
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.5
    • /
    • pp.1013-1022
    • /
    • 2017
  • Windows hibernation is a function that stores data of physical memory on a non-volatile media and then restores the memory data from the non-volatile media to the physical memory when the system is powered on. Since the hibernation file has memory data in a static state, when the attacker collects it, key information in the system's physical memory may be leaked. Because Windows does not support protection for hibernation files only, we need to protect the memory that is written to the hibernate file. In this paper, we propose a method to encrypt the physical memory data in the hibernation file to protect the memory data of the processes recorded in the hibernation file. Hibernating procedure is analyzed to encrypt the memory data at the hibernating and the encryption process for hibernation memory is implemented to operate transparently for each process. Experimental results show that the hibernation process memory encryption tool showed about 2.7 times overhead due to the crypt cost. This overhead is necessary to prevent the attacker from exposing the plaintext memory data of the process.

Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF

The Effect of Spacer on Microclimate and Comfort Sensation in Protective Clothing for Firefighters

  • Chung, Gi-Soo;Lee, Dae-Hoon
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.564-566
    • /
    • 2002
  • Protective clothing for firefighters typically consists of a flame resistant outer shell and inner layers. The inner layers are generally composed of a moisture barrier and a thermal barrier. On performing the task in fire place the heat and perspiration generated from the body become trapped inside the protective clothing. Those heat and moisture result into heat-stress and physical fatigue of fire fighter, which hinder the work. Therefore, the system of clothing designs and material layers must be chosen carefully to balance protection and comfort. 3 kinds of protective clothing of 3 layer structure were used in the experiment of physiological comfort. From the comparison of wear trials with the 3 kinds of layers in firefighters clothing, it indicates that the moisture dissipation of A+B2+C was highest, following A+BI+C andA+B3+C. And the heat dissipation of A+BI+C and A+B2+C were better than A+B3+C. In the protective clothing with A+B3+C, heat and perspiration generated through exercise remained in clothing system long and caused discomfort.

Electronic Security Control Center Building Process and Security and Management Measures (시스템경비 관제시설의 구축과 보안 및 경영대책)

  • Ha, Kyung-Su;Cho, Cheol-Kyu;Kim, Pyong-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.5
    • /
    • pp.113-121
    • /
    • 2015
  • This research suggests construction processes and security solutions for security control center as management measures for security management improvement in domestic electronic security companies. Security control center (SCC) is the central nerve of electronic security service, and no matter how well the on-site response system has been built, if SCC ceases to work due to an incident or disaster or security control personnel are harmed, the electronic security system cannot perform its proper functions. It is divided to a spatial structure, the infrastructure, control equipment, control solutions and operating structure in a construction process in the security control center. And a solution can be presented for physical security, information security, and personnel security in the way to security solutions.

Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages (임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

A Study on the Regulatory Standards and Rationale of OTT Adoption (OTT 도입의 규제 기준과 근거에 대한 연구)

  • Kim, Hee-Kyung;Do, Joonho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.141-148
    • /
    • 2022
  • New services such as OTT have appeared, and the value chain of the media industry has formed a complex terrain, and new problems have arisen in terms of fair competition between operators and user protection. However, the problem of introducing OTT under the existing law that classifies services by physical characteristics and technical elements of the network has been criticized in terms of hindering industrial activation due to excessive regulation. The introduction of the new regulatory system has been delayed for a long time despite the dissatisfaction of stakeholders and attempts to legislate