• Title/Summary/Keyword: Physical Optic

검색결과 78건 처리시간 0.261초

An Study on Effective Maintenance and Operation System of Fiber Optic Lines (효과적인 광선로 유지 보수를 위한 시스템 개발에 관한 연구)

  • Jang, Eun-Sang;Park, Kap-Seok;Kim, Seong-Il;Choi, Sin-Ho;Lee, Byeong-Wook
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.54-57
    • /
    • 1998
  • As the physical layer on telecommunication network is replaced fiber optic lines, it is increased the need of systematic maintenance for fiber optic lines. Korea Telecom has developed FLOMS in order to establish maintenance processes for optical fiber lines. FLOMS has functions which manages optical facilities and tests optical fiber lines automatically. As a resuls, this system can check and/or report a fault. Operator, who is reponsible for management of optical fiber lines, can test the characteristics of optical fiber lines remotely using FLOMS. As interpoerable with Digital Transmission Management System, FLOMS provides efficient management for optical fiber lines. This system improves the work process to find fault location fast, detect the degradation of fiber quality, and make database of optical facilities efficiently.

  • PDF

Temperature Measurement Using Single-Mode Fiber Interferometric Sensor (단일모드 광섬유의 간섭계 센서를 이용한 온도측정)

  • 김덕수;이상호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제22권2호
    • /
    • pp.1-5
    • /
    • 1985
  • In this paper, temperature-induced optical phase shifts in single-mode fibers are studied both analytically and experimentally. Temperature sensor using single-mode fiber interferometer is designed and the temperature sensitivity of the sensor system is investigated. This fiber-optic temperature sensor which employs the Mach-Zehnder arrangement is a high sensitivity sensor of phase detection type. In this type, temperature changes are ob-served as a motion of an optical interference fringe pattern. In the measurements using interferometer, one of the important problems is to detect simultaneously the number and direction of fringe displacement resulting from physical perturbations (temperature, pressure, etc.). To realize this, the array detector using multi-mode fiber is designed. By this array detector the number and direction of fringe displacement is Ineasured very conveniently.

  • PDF

Hetero-core Spliced Fiber Optical Sensing System for an Environment Monitoring (구조물 모니터링을 위한 헤테로 코어형 광센싱 시스템)

  • Kim, Young-Bok;Lee, Kwon-Soon;Watanabe, Kazuhiro;Sasaki, Hiroyuki;Choi, Yong-Woon
    • Journal of Ocean Engineering and Technology
    • /
    • 제21권3호
    • /
    • pp.46-51
    • /
    • 2007
  • A multi-purpose environmental monitoring system has been developed as a commercially available standard using the technique of hetero-core spliced fiber optic sensors, for the purposes of monitoring large-scale structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition, in view of the full-scale operation at actual sites to be monitored. Additionally, the developed system in this work conveniently provides us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. Two channels of optical fiber line were monitored in each channel, three displacement sensor modules were connected in series, in order to examine the performance to a pseudo-cracking experiment in the outdoor situation and to clarify temperature influences an the system, in terms of the coupling of optical connectors and the OTDR stability. The results from the pseudo-cracking experiment agreed with the actual cracks, by means of calculation, based an the detected displacement values and their geometrical arrangement of the used sensor modules. The temperature change, ranging from 10 to $20^{\circ}C$ resulting from the 10-days free running operation, was found to influence the system stability of ${\pm}10{\mu}m$, primarily due to the coupling instability of the used optical connectors. It was found that fusion splicing, rather than the use of connectors, reduced the fluctuation dawn to ${\pm}2{\mu}m$. The specification and performance of various option modules have been demonstrated to show the capability of inspecting various physical quantities by use of the single system, which would be suitable for multi-purpose environmental monitoring.

The characteristics of nonlinear magneto-optical effect based on coherent population trapping in the D1 line of Rh atoms (87Rb D1 전이선에서 원자결맞음을 이용한 비선형 광자기 효과 신호의 특성)

  • Lee, L.;Moon, H.S.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 2006
  • We investigated the characteristics of the nonlinear magneto-optic effect (NMOE) depend on the transitions, the laser intensity and the temperature of the vapor cell, in the $D_1$ transition of $^{87}Rb$ atoms by using the Rb vapor cell contained with buffer gas of Ne 6.7 kPa. The size and the width of NMOE signal were increased according to the light intensity and temperature in the transition of F=2$\to$F'=2. However, In the case of using the F=2$\to$F'=1 transition, the size of the signal could be increased according to the light intensity without additional broadening of the width. We confirmed that the sensitivity of detecting small magnetic flux improved in this transition, and explained these effects by the different of the CPT configuration between Zeeman sublevels. At the optimal condition in experiment, the sensitivity of this system was evaluated less then $70pT/\sqrt{Hz}$.

An Algorithm for Virtual Topology Design in WDM optical Networks under Physical constraints. (파장분할다중화방식 전광통신망에서 물리적 제약을 고려한 가상망 설계 알고리즘)

  • 유지연;김상완;서승우;장문종;우희곤
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제25권3A호
    • /
    • pp.443-450
    • /
    • 2000
  • Although designing a virtual topology for all-optical WDM wide-area networks has been extensively studied and several algorithms have been proposed, these algorithms assumed error-free communication between two nodes. However, noises from optical amplifiers and optical cross-connects can degraded the signal, resulting in a nonzero bit-error rate. In this paper, we investigate the effect of physical limitations on the virtual topology design. We show that for side-area all-optical networks where transmission distance is fairly long, virtual topology design algorithm that can determine the locations of opto-electronic(OE) and electro-optic(EO) conversions to set up a connection request with a high BER in a multihop manner.

  • PDF

High Purification of Hg2Br2 Powder for Acousto-Optic Tunable Filters Utilizing a PVT Process (PVT공정을 이용한 음향광학 가변 필터용 Hg2Br2 파우더의 고순도 정제)

  • Kim, Tae Hyeon;Lee, Hee Tae;Kwon, In Hoi;Kang, Young-Min;Woo, Shi-Gwan;Jang, Gun-Eik;Cho, Byungjin
    • Korean Journal of Materials Research
    • /
    • 제28권12호
    • /
    • pp.732-737
    • /
    • 2018
  • We develop a purification process of $Hg_2Br_2$ raw powders using a physical vapor transport(PVT) process, which is essential for the fabrication of a high performance acousto-optic tunable filter(AOTF) module. Specifically, we characterize and compare three $Hg_2Br_2$ powders: $Hg_2Br_2$ raw powder, $Hg_2Br_2$ powder purified under pumping conditions, and $Hg_2Br_2$ powder purified under vacuum sealing. Before and after purification, we characterize the powder samples through X-ray diffraction and X-ray photoelectron spectroscopy. The corresponding results indicate that physical properties of the $Hg_2Br_2$ compound are not damaged even after the purification process. The impurities and concentration in the purified $Hg_2Br_2$ powder are evaluated by inductively coupled plasma-mass spectroscopy. Notably, compared to the sample purified under pumping conditions, the purification process under vacuum sealing results in a higher purity $Hg_2Br_2$ (99.999 %). In addition, when the second vacuum sealing purification process is performed, the remaining impurities are almost removed, giving rise to $Hg_2Br_2$ with ultra-high purity. This high purification process might be possible due to independent control of impurities and $Hg_2Br_2$ materials under the optimized vacuum sealing. Preparation of such a highly purified $Hg_2Br_2$ materials will pave a promising way toward a high-quality $Hg_2Br_2$ single crystal and then high performance AOTF modules.

Demonstration of the Usefulness of Optical Coherence Tomography in Imaging a Mouse Tail Model of Lymphedema

  • Kim, Hui Dong;Kim, Dong Kyu;Chae, Yu-Gyeong;Park, Seok Gyo;Kim, Ghi Chan;Jeong, Ho Joong;Sim, Young-Joo;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.132-137
    • /
    • 2017
  • To investigate the usefulness of optical coherence tomography (OCT) for imaging lymphedema, we directly compared it to other histological methods in a mouse model of lymphedema. We performed detailed imaging of the lymphedema lesion on a mouse tail. We imaged the mouse tail in vivo with OCT and created histopathological samples. We constructed a spectrometer-based OCT system using a fiber-optic Michelson interferometer. The light was directed to 50:50 couplers that split the light into reference and sample arms. Backscattered light from a reference mirror and the sample produced an interference fringe. An OCT image of the lymphedema model revealed an inflammatory reaction of the skin that was accompanied by edema, leading to an increase in the light attenuation in the dermal and subcutaneous layers. Similar to OCT image findings, histological biopsy showed an inflammatory response that involved edema, increased neutrophils in epidermis and subdermis, and lymphatic microvascular dilatation. Furthermore, the lymphedema model showed an increase in thickness of the dermis in both diagnostic studies. In the mouse tail model of lymphedema, OCT imaging showed very similar results to other histological examinations. OCT provides a quick and useful diagnostic imaging technique for lymphedema and is a valuable addition or complement to other noninvasive imaging tools.

The Analysis of Dual Beam Offser-fed Dish Antenna (이중빔 옵셋안테나 해석)

  • 박경환;이행선;양군백;강동균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제11권7호
    • /
    • pp.1247-1257
    • /
    • 2000
  • Offset-fed dish antennas are considered. Offset-fed dish antennas are widely used for DBS reception, the problem of offset-fed dish antenna has, however, received little attention because of its complicated and asymmetric geometry. A Fourier-transform technique and Physical Optics are employed to express the fields radiated from offset-fed reflector and feed horn aperture. The simultaneous equations are solved to obtain a solution in a fast convergent series, thus facilitating the numerical computation. For given parameters such as diameter of reflector, focal length, offset height of reflector center, exact solutions are derived. Since offset-fed dish antenna has an application as multi-beam antenna using multiple feed, a brief feasablity of dual beam antenna for Korea-SAT (116$^{\circ}$E, EIRP 59 dBW) and Orion-SAT (139$^{\circ}$E, EIRP 54 dBW) is given in Conclusion.

  • PDF

Mercurous bromide $(Hg_2Br_2)$ crystal growth by physical vapor transport and characterization

  • Kim, S.K.;S.Y. Son;K.S. Song;Park, J.G.;Kim, G.T.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제12권6호
    • /
    • pp.272-282
    • /
    • 2002
  • Mercurous bromide ($Hg_{2}0Br_{2}$) crystals hold promise for many acousto-optic and opto-electronic applications. This material is prepared in closed ampoules by the physical vapor transport (PVT) growth method. Due to the temperature gradient between the source and the growing crystal region, the buoyancy-driven convection may occur. The effects of thermal convection on the crystal growth rate was investigated in this study in a horizontal configuration for conditions ranging from typical laboratory conditions to conditions achievable only in a low gravity environment. The results showed that the growth rate increases linearly with Grashof number, and for 0.2 $\leq$ Ar (transport length-to-height, L/H)$\leq$1.0 sharply for Ar=5 and $\Delta$T=30 K. We have also shown that the magnitude of convection decreases with the Ar. For gravity levels of less than $10^{-2}$g the non-uniformity of interfacial distribution is negligible.

Atmospheric Correction and Velocity Aberration for Physical Sensor Modeling of High-Resolution Satellite Images (고해상도 위성영상의 센서모델링을 위한 대기 및 속도 보정)

  • Oh, Jae-Hong;Lee, Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제29권5호
    • /
    • pp.519-525
    • /
    • 2011
  • High-resolution earth-observing satellites acquire substantial amount of geospatial images. In addition to high image quality, high-resolution satellite images (HRSI) provide unprecedented direct georegistration accuracy, which have been enabled by accurate orbit determination technology. Direct georegistration is carried out by relating the determined position and attitude of camera to the ground target, i.e., projecting an image point to the earth ellipsoid using the collinearity equation. However, the apparent position of ground target is displaced due to the atmosphere and satellite velocity causing significant georegistration bias. In other words, optic ray from the earth surface to satellite cameras at 400~900km altitude refracts due to the thick atmosphere which is called atmospheric refraction. Velocity aberration is caused by high traveling speed of earth-observing satellites, approximately 7.7 km/s, relative to the earth surface. These effects should be compensated for accurate direct georegistration of HRSI. Therefore, this study presents the equation and the compensation procedure of atmospheric refraction and velocity aberration. Then, the effects are simulated at different image acquisition geometry to present how much bias is introduced. Finally, these effects are evaluated for Quickbird and WorldView-1 based on the physical sensor model.