• Title/Summary/Keyword: Physical Measurements

Search Result 1,761, Processing Time 0.031 seconds

Intertester and Intratester Reliability of Tape Measurement on Lower Extremities (줄자를 이용한 하지부피 측정시 부위별 검사자간, 검사자내 신뢰도 측정)

  • Kim, Seng-Jung;Yang, Hoi-Song;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.7 no.1
    • /
    • pp.38-45
    • /
    • 2000
  • Tape measurement for evaluating edema is frequently used by clinicians. The primary purpose of this study is to determine the intertester and intratester reliability of tape measurement carried out by two physical therapists on lower extremities. The intertester and intratester reliability of six anatomical landmarks measurements were determined in six healthy subjects. The measurements were taken in five sessions by each tester. The intraclass correlation coefficients (2,1) were between .87 and .99 for intertester reliability. Intratester reliability was .93 and .99 for A tester and .82 and .99 for B tester. The average range of variation was .13 to .54 in six landmarks. The reliability of six volume measurements was very high. These results support the use tape measurement as a reliable tool for measuring limb girth.

  • PDF

Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion (측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구)

  • Lee, So-Joon;Hur, Young-Gu
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

Comparison of the Effects of Different Crutch Length Measurement Methods on Trunk Muscle Activities in Young Females (젊은 여성의 몸통 근육 활성도 분석을 통한 목발 길이 측정 방법의 효율성 비교)

  • Jeon, Hyun;Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2020
  • PURPOSE: This study compared the activities of the trunk muscles during crutch walking to determine which of the crutch length measurements is most beneficial. METHODS: Twenty young women volunteered to participate in this study. After adjusting crutch length, the participants performed a three-point walking with nondominant leg limited in weight bearing. This study used six crutch length measurements: (1) Height-40.6cm, (2) Height'.77, (3) Olecranon-to-finger length, (4) Axillary-toheel length, (5) Arm-span length-40.6cm, and (6) Arm-span length'.77. The EMG activities of the internal oblique (IO), rectus abdominis (RA), multifidus (MF), and erector spinae (ES), muscles on the weight bearing side were monitored using wireless surface EMG. RESULTS: The EMG activities of the RA and ES appeared to be significantly different among the crutch length measurements (p<.05). The post-hoc test showed that the 'Arm-span length-40.6cm' was significantly greater in the RA activity when compared to the 'Height'.77' and 'Axillary-to-heel length' measurements, and in the ES activity when compared to 'Height'.77' measurements. Furthermore, IO/RA and MF/ES ratios showed significant differences among the crutch length measurements (p<.05). In the post-hoc test, significant difference was observed between 'Olecranon-to-finger length' and 'Arm-span length-40.6cm' for the IO/RA ratio, and between 'Height'.77' and 'Olecranon-to-finger length' and between 'Height'.77' and 'Arm-span length-40.6cm' measurement for the MF/ES ratio. CONCLUSION: These findings suggest that the 'Height'.77' measurement is relatively advantageous to optimize the activities of trunk muscles during the crutch walking, and allow simple measurements of the crutch length.

Effects of Kinesio Taping Applied on the Ankle Instability to Range of Motion and Balance (발목 불안정성에 키네시오 테이핑적용이 관절가동범위 및 균형에 미치는 영향)

  • Seo, Tae-hwa;Go, Hyun-min;Park, Jong-hang;Kim, Yoon-hwan;Kim, Tae-won;Park, Hyun-sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Background: To evaluate the effect of Kinesio taping applied on the ankle instability, joint range of motion and balance. Methods: The participants included in this study were male and female, 20~30 ages, who experiencing an ankle sprain or had chronic pain, did not exercise during the intervention, and did not experience severe exercise at least 3 weeks before. A total of twenty-four participants were divided into two groups: Kinesio taping applied group (n=12) and control group (n=12). The experiment was conducted for a three days. Measurements were taken for ankle joint range of motion using goniometer, and measurements were taken for balance using good balance system. Pre-test measurements were conducted on before Kinesio taping apply, and 24 hours after, 48 hours after, 72 hours after measurements were conducted. Statistical analysis was done using a independent samples t-test and repeated measure ANOVA. Results: There were significant differences to the duration of intervention in ankle joint range of motion and balance within the both group. However, there was a significant differences Kinesio taping group when comparing the groups. Conclusions: According to the results of this study, applying Kinesio taping to ankle instability is more effective on ankle joint range of motion and to recover balance.

  • PDF

A Study on Body Types Characteristics of Mongolian Men (몽골 남성의 체형특성에 관한 연구 - 18~24세를 중심으로 -)

  • Im, Soon;Kim, Sang-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.1
    • /
    • pp.141-151
    • /
    • 2010
  • The purpose of the study was to offer basic documents to the textile fashion industry by investigating changes of figures by various factors as each other social and environment. This study analyzes characterization and classification of body types of Mongolian men. 100 adult subjects within the 18 to 24 age group were studied. The physical measurements of the research subjects come up to a total of 63 items. Data was statistically analyzed with SPSS program using basic statistics, t-test, one-way ANOVA, Duncan-test, factor analysis and cluster analysis. The conclusions are as follows. In the result of factors analysis in physical measurements of Mongolian men, 10 factors such as the vertical size of body, on the obesity of body, the leg size, the bust from back length, the bust from front length, the shoulder size were extracted. The accumulated contributory rate of these was 73.86%. The cluster analysis for the comparison of the body types, by categorizing the body types produced three types. The comparison of 45 items in physical measurements between Korean men and Mongolian men resulted in the differences in 20 items. While the height items including stature between them showed negligible differences.

  • PDF

A Study on Body type Characteristics of Mongolian Women (몽골 성인 여성의 체형특성에 관한 연구)

  • Im, Soon;Kim, Sang-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.9 no.3
    • /
    • pp.75-85
    • /
    • 2007
  • This study analyzes characterization and classification of body types of Mongolian women. 100 adult subjects within the 20 to 49 age group were studied. The physical measurements of the research subjects come up to a total of 50 items. Data was statistically analyzed with SPSS program using basic statistics, t-test, one-way ANOV A, Duncan-test, factor analysis and cluster analysis. The conclusions are as follows. In the result of factors analysis in physical measurements of Mongolian women, 7 factors such as on the obesity of body, the vertical size of body, hip length, the bust from back length, the bust from front length, the ankle size and the shoulder size were extracted. The accumulated contributory rate of these was 70.7%. The cluster analysis for the comparison of the body types, by categorizing the body types produced three types. Mongolian women were grouped as those with the short stature and light weight, the medium stature and heavy weight, the tall stature and medium weight. The comparison of 50 items in physical measurements between Korean women and Mongolian women resulted in the differences in 39 items. While the height items including stature between them showed negligible differences, most of the length items relating to breadth, circumference, depth and obesity showed differences, which were big.

  • PDF

Reliability of Navicular Drop Measurements in Standing and Sitting Positions

  • Park, Ji-Won;Chang, Jong-Sung;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.6
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: This study was designed to investigate inter-rater and intra-rater reliability of navicular drop measurements by clinicians in sitting and standing positions. Methods: Fourteen subjects with pronated foot were recruited. Two physical therapists randomly assessed the same patients on different occasions but on the same day. Almost all patients were assessed on more than one day. The intra-rater and inter-rater reliability of navicular dropwas estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of navicular drop measurements ranged from 0.93 to 0.87, the inter-rater reliability from 0.98 to 0.70 with the patient in standing and sitting positions. These results showed good reliability for calculated variables. Intra-rater and inter-rater reliability of navicular drop in standing position was higher than those of sitting position. Conclusion: Although inter-rater and intra-rater reliability of navicular drop in the sitting position was lower than in the standing position, measurement of navicular drop in the sitting position showed good reliability and was acceptable for patients who could not stand alone without assistance. We recommend that having the patient in the standing position is appropriate in navicular drop measurement.

The Effects of Gluteus Medius Strength Training on Ankle Stability in Patient with Chronic Ankle Sprains (중간볼기근 강화운동이 만성 발목염좌 환자의 발목 안정성에 미치는 효과)

  • Kim, Yoon-hwan;Park, Su-hyung;Song, Hyun-seung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • Background: The purpose of this study was to investigate the effects of gluteus medius strength exercise on the ankle stability of high school student with chronic ankle sprains. Methods: A total of 30 participants were divided two groups. Experimental group was 15 participants applied gluteus medius strength exercise. Control group was 15 participants performing ankle strength exercise. This study was performed for 50 minutes per day, three a week for 6 weeks. All measurements were taken to a pre and post test. Strength was measured using Power Track ll. Balance was measured using Biodex balance system for Limits of Stability and Postural Stability. Ankle Stability was measured using Cumberland Ankle Instability Tool (CAIT). Results: In the case of gluteus medius strength, there were statistically significant differences between the experimental group and the control group. For ankle stability were statistically significant differences within the experimental group according to measurements taken by Limits of Stability, Postural Stability, and CAIT. A between group comparison showed a statistically significant difference for CAIT only. Conclusion: According to our measurements it appears that gluteus medius strength training was effective in benefiting muscular strength, balance and ankle stability among the physical education.

The Reliability of Thickness Measurement of the Deep Fiber of the Lumbar Multifidus Using Ultrasonography

  • Jung, Doh-Heon;Kim, Su-Jung;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • The reliability of the thickness measurement of the lumbar multifidus (LMD using real-time ultrasonography (US) was determined in only the superficial fiber of the lumbar multifidus (SM). However, previous studies have not examined the reliability of the deep fiber of the LM (DM). The purpose of this study was to determine the intrarater and the interrater reliability of the thickness measurements of DM using US. Eleven heathy males participated in the study. The thickness of the DM was measured with an US in the prone position. Reliability was examined using intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland and Altman plot. ICC(3,1) was used to calculate the interrater reliability of the thickness measurement of DM using the values from both the first and second test sessions. Additionally, ICC(3,1) was used to calculate the intrarater reliability of the measurements over two days using the measurements obtained in test session 1 and lest session 2. The results of this study were as follows: 1) the ICC(3,1) value for interrater reliability was .94 in the first test session, and .93 in the second test session. 2) the ICC(3,1) values for intrarater reliability of the measurements over two days was .90 in both the first examiner and the second examiner. The interrater reliability and interrater reliability of the DM measurements, obtained via the US protocol used in this research was excellent. Therefore, we conclude that the thickness measurement of the DM obtaioned from the US protocol used in this research would be useful for clinician assessment of the thickness of the DM.

RELIABILITY and VALIDITY of DUAL PROBE-FIXING FRAME for REHABILITATIVE ULTRASOUND IMAGING for EXERCISES with VISUAL FEEDBACK

  • Na-eun Byeon;Jang-hoon Shin;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.259-267
    • /
    • 2023
  • Objective: Rehabilitative ultrasound imaging is a safe and noninvasive technique for evaluating muscle thickness. A dual probe-fixing frame (DPF) can provide visual feedback during exercises targeting specific muscles. The purpose of this research was to verify the reliability and validity of the DPF for dual-probe ultrasound (DPU)-based visual feedback exercises, allowing users to use both hands freely. Design: This cross-sectional study used repeated measures to compare muscle thickness measurements obtained using the handheld device and DPF with DPU. Methods: Twenty healthy adults participated in the study. Measurements were taken over two sessions, with a two-day interval between the sessions. The thicknesses of the rectus abdominis (RA) and transverse abdominis (TrA) muscles were measured using DPU. The DPF with DPU developed by the research team, was used along with a laptop-based muscle viewer. Bland-Altman analysis and intraclass correlation coefficients (ICCs) calculations were used in statistical analyses to evaluate agreement and reliability, respectively. Results: The results of the Bland-Altman analysis showed small average differences between the handheld and DPF methods for both RA and TrA muscle thicknesses. Inter-rater reliability analysis showed high ICC values for DPF measurements of both RA (0.908-0.912) and TrA (0.892-741) muscle thicknesses. Intra-rater reliability analysis also showed good ICC values for measurements taken by a single examiner over two days. Conclusion: The findings of this study demonstrate that the DPF provides reliable and valid measurements of muscle thickness during visual feedback exercises using the DPU.