Study on an Electrode Attachment Method Suitable for Underwater Electromyography Measurements

  • Han, Seul-ki;Park, Jung-seo;Nam, Taek-gil
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.95-98
    • /
    • 2015
  • PURPOSE: This study was conducted to devise a method of preventing water infiltration into the surface electrodes during EMG measurements underwater and on the ground and to check the reliability of Electromyography (EMG) measurements when underwater. METHODS: Six healthy adults were selected as subjects in this study. The measurements in this study were conducted in pool dedicated to underwater exercise and physical therapy room in the hospital building. An MP150 (Biopac Systems, US, 2010) and a BioNomadix 2-channel wireless EMG transmitter (Biopac Systems, US, 2012) was used to examine the muscle activity of rectus femoris, biceps femoris, tibialis anterior, gastrocnemius of dominant side. The subjects repeated circulation tasks on the ground for more than 10 min for enough surface electrode attachment movement. After a 15-min break, subjects performed the circulation task underwater(water depth 1.1m, water temperature $33.5^{\circ}C$, air temperature $27^{\circ}C$), as on the ground, for more than 10 min, and the MVIC of each muscle was measured again. SPSS v20.0 was used for all statistical computations. RESULTS: The maximum voluntary isometric contraction (MVIC) values between the underwater and on the ground measurements showed no significant differences in all four muscles and showed a high intraclass correlation coefficient (ICC) of >0.80. CONCLUSION: We determined that EMG measurements obtained underwater could be used with high reliability, comparable to ground measurements.

엄지발가락휨각도 측정을 위한 각도계의 신뢰도와 타당도 (Reliability and Validity of the Goniometer for Hallux Valgus Angle Measurement)

  • 정성대;강선영;김문환;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.46-51
    • /
    • 2013
  • The purpose of this study was to investigate the reliability and validity of goniometer measurements of the hallux valgus angle (HVA) compared to radiographic measurements, which are the current standard. Twenty subjects (10 female, 10 male) were recruited for this study (40 feet). The HVA of the subjects was measured using goniometer and radiographic measurement. In three trials, measurements were taken of each subject by two examiners using goniometer and radiographic measurements using radiography in a standing position. The reliability of the measurements was investigated using intraclass correlation coefficients (ICC(3,1)), and the validity was tested using the Pearson product-moment correlation coefficient and an independent t-test. The intra-rater reliability of left and right HVAs were poor (ICC=.409 and .341, respectively). The inter-rater reliability of left and right HVAs were poor and moderate (ICC=.303 and .501, respectively). Left and right HVAs measured using goniometer and radiographic measurements were also poor and moderate (Pearson r=.246 and .544, respectively). These results suggest that goniometer measurements of the HVA are inaccurate and have unacceptable validity compared to radiographic measurements.

20대 남성의 하반신 체형별 신체인식에 관한 연구 (A Study on Physical Recognition of Men in Their Twenties by Body Shape of the Lower Parts of the Body)

  • 은영자;김선혜
    • 복식문화연구
    • /
    • 제12권3호
    • /
    • pp.485-496
    • /
    • 2004
  • The purpose of this study conducted a survey on 356 men in their twenties to investigate their recognition of their bodies. Also physical measurements were conducted on them and the lower parts of the bodies were classified into several types. The study examined the relevance of the subjects' recognition of their bodies to the physical types of the lower parts of the body. The results can be summarized as follows; There are four factors that constitute the physical shapes of the lower parts of the body and the lower parts of the body are classified into three physical types by cluster analysis. In terms of the degree of recognition of lower parts of the body shapes, the respondents' recognition of their bodies was similar to the actual measurements except for heights and leg lengths regardless of physical types, showing that they recognized well their actual physical types. With respect to the degree of satisfaction with body types, the surveyed were dissatisfied with thick circumference items and short length items. The actual measurements and the degree of recognition showed significant correlations in almost all the items while the actual measurements and the degree of satisfaction showed significant negative correlation in the circumference items. The degree of satisfaction with heights showed significant correlations with almost all measurements, demonstrating that the degree of satisfaction of the males in their twenties with the lower pats of body has closer correlations with the height items of the actual measurements that the circumference items. The degree of satisfaction with bodies was more dependent on people's recognition than the actual measurements.

  • PDF

The Correlation of Anthropometric Measurements, Physical Performance and Biochemical Measurements with Nutrient Intakes in Male College Students

  • Cho, Youn-Ok;Kim, Bo-Young
    • Nutritional Sciences
    • /
    • 제6권2호
    • /
    • pp.113-117
    • /
    • 2003
  • Possible correlations between nutrient intake add health status-as assessed by anthropometric measurements, physical performance and biochemical measurements-were investigated, using 514 healthy young men aged 20 years old who had no apparent health problems. The intakes of nutrients were estimated using a three-day dietary recall method. Height and body weight were measured, and body mass index (BMI) was calculated. Physical performance was tested using sit-ups, push-ups, a loom sprint and a 1,500m run. When compared with the Korean recommended dietary allowances (Korean RDA), the subjects nutrient intakes were adequate except for calcium. The intake of calcium was 516.66$\pm$293.43mg/day, which is 73.80 % of the Korean RDA. The subjects averaged 174.51$\pm$7.07cm in height, 68.17$\pm$9.25 kg in body weight and 22.23$\pm$2.16 in BMI. The associations between nutrient intakes and anthropometric measurements, and between nutrient intakes and physical performance, were weak. The intake of vegetable fat was positively correlated to body weight, whereas the intake of carbohydrate was negatively correlated to BMI. The intake of carbohydrate was positively correlated to the level of performance in the loom sprint, and the intake of vegetable Int was positively correlated to the level of performance of sit-ups. No correlation was found between nutrient intakes and the following biochemical measurements of the blood: the levels of glucose, total protein, total cholesterol, triglyceride, hemoglobin and hematocrit. These results suggest that anthropometric measurements and level of physical performance can be associated with energy nutrient intakes, even in moderately active, well-nourished, young men. No correlation was found between nutrient intake and biochemical measurements, probably because all subjects had a reasonably well-balanced diet.

1개 초등학교 3학년생의 슬괵근 유연성 평가 (A Flexibility Assessment of Hamstring Muscle Length in 10year old Children as Affected the Long-sitting Position)

  • 주민;권기준;강성국;권활란;박동빈;박전정
    • The Journal of Korean Physical Therapy
    • /
    • 제12권1호
    • /
    • pp.73-78
    • /
    • 2000
  • The Sit-and-Reach Test (SRT) is commonly nea to assess flexibility of the spine and length of the hamstring muscle, The purpose of this study was to describe hamstring muscle length as reflected by use of the SRT, the Hip Joint Angle (HJA) and Sack length(from C7 to S2) in children, to examine the correlation between Back length, SRT and HJA measurements and to examine gender differences. The 162 subjects were participated without known musculoskeletal and neurological impairments of their spine or lower exeremities. In the Long-silting position, the Back length, SRT and HJA measurements were obtained. A mean Back length value of 46.2cm, a mean SRT value of 29.4cm and a mean HJA of 77,0 degrees were obtained including all subjects. There was a strong correlation between the SRT and HJA measurements (r=.66). There were a difference between boys and girls in Back(p=.0019) and HJA measurements (p=.015). The results of this study suggest that measurements for the SRT and HJA were correlated than Back. The HJA measurements guide treatment more effectively than do Back length and SRT measurements.

  • PDF

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도 (Reliability and Validity of the Manual Measurement Method for Patellar Height)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

The Comparison of Clinical Assessment Tools for the Foot Posture

  • Lee, Jin-Yi;Choi, Jong-Duk
    • 한국전문물리치료학회지
    • /
    • 제19권3호
    • /
    • pp.115-123
    • /
    • 2012
  • It is important to assess foot posture when investigating the relationship between lower extremity dysfunctions and foot types. Although several measurements of static foot posture have been used, there is no consensus regarding clinical measurements for foot posture. The aim of this study is to explore the differences among navicular drift (NDt), foot posture index (FPI), arch index (AI), dorsal arch height ratio (DAHR), normal navicular height truncated (NNHt) and to discover the most effective measurement. After foot types were classified by navicular drop test (NDp), clinical measurements of NDt, FPI, AI, DAHR, and NNHt were performed on 64 subjects' feet. ANOVA analysis was used for the variance of the difference between the NDp and the five kinds of clinical measurements, and the level of significance was set at ${\alpha}$=.05. The results showed that all five clinical measurements demonstrated significant differences with navicular drop. In post-hoc, FPI and NNHt showed significant differences in all foot types. The five clinical measurements are suitable the classification of foot types through the NDp. Therefore, it could be possible to assess correct and objective foot posture by using FPI and NNHt.

3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로- (A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data-)

  • 한현숙;남윤자
    • 한국의류학회지
    • /
    • 제33권8호
    • /
    • pp.1190-1202
    • /
    • 2009
  • A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.