• Title/Summary/Keyword: Physical Cleaning

Search Result 188, Processing Time 0.026 seconds

Evaluation of the efficiency of cleaning method in direct contact membrane distillation of digested livestock wastewater

  • Kim, Sewoon;Park, Ki Young;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.113-123
    • /
    • 2017
  • This study investigated effects of physical and chemical cleaning methods on the initial flux recovery of fouled membrane in membrane distillation process. A laboratory scale direct contact membrane distillation (DCMD) experiment was performed to treat digested livestock wastewater with 3.89 mg/L suspended solids, 874.7 mg/L COD, 543.7 mg/L nitrogen, 15.6 mg/L total phosphorus, and pH of 8.6. A hydrophobic PVDF membrane with an average pore size of $0.22{\mu}m$ and a porosity of 75 % was installed inside a direct contact type membrane distillation module. The temperature difference between feed and permeate side was maintained at $40^{\circ}C$ with the feed and permeate stream velocity of 0.18 m/s. The results showed that the permeate flux decreased from $22.1L{\cdot}m^{-2}{\cdot}hr^{-1}$ to $19.0L{\cdot}m^{-2}{\cdot}hr^{-1}$ after 75 hours of distillation. The fouled membrane was cleaned first by physical flushing and consecutively by chemicals with NaOCl and citric acid. After the physical cleaning the flux was recovered to 92 % as compared with the initial clean water flux of the virgin membrane. Then 94 % of the flux was recovered after cleaning by 2,000 ppm NaOCl for 90 minutes and finally 97 % of flux recovered after 3 % citric acid for 90 minutes. SEM-EDS and FT-IR analysis results presented that the foulants on the membrane surface were removed effectively after each cleaning step. The contact angle measurement showed that the hydrophobicity of the membrane surface was also restored gradually after each cleaning step to reach nearly the same hydrophobicity level as the virgin membrane.

A Study on Patients' satisfaction for quality improvement of Physical Therapy service (물리치료실의 질 향상(QI)을 위한 내원 환자의 만족도에 관한 연구)

  • Kwon, Chun-Suk;Han, Dang-Uck
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.483-494
    • /
    • 2000
  • The purpose of this study was to contribute to quality improvement with physical therapy service and determining the factors affecting patients' satisfaction. The study subjects were ambulatory and admitted patients treated with physical therapy at B general hospital located in Taejon from July 15, 2000 to July 21. Authors developed structured questionnaire, and distributed it to each physical therapist of B general hospital. Total number of distributed questionnaire was 164, and 157 questionnaire were collected and analysed finally. Demand of physical therapy for quality improvement(QI) related to treatment time(r =0.746, P<01), treatment method(r =.664, P<.01). treatment effect(r=0.648, P<.01), equipments(r=0.620, P<.01), cleaning status(r =0.619, P<.01). Willingness to revisit and recommendation of this physical therapy room related to treatment method(r=0.489, P<.01), treatment time(r=0.469, P<.01), cleaning status(r=0.432, P<.01).

  • PDF

Alteration of Physical and chemical Characteristics of Waterlogged Archaeological Woods After Cleaning (세척 후 수침고목재의 물리.화학적 특성 변화)

  • Cha, Mi-Young;Lee, Kwang-Ho;Kim, Yoon-Soo
    • Journal of Conservation Science
    • /
    • v.19
    • /
    • pp.19-30
    • /
    • 2006
  • Alteration of physical and chemical characteristics and the effect of removal of mineral substances in waterlogged archaeological woods by different cleaning processes were examined using oak wood(Quercus spp.) that was excavated from wetland near Gwangju, Korea. Cleaning methods employed in the present work were (1) tools, (2) deaeration, (3) EDTA and (4) ultrasonic cleaning, which are being currently applied in the field of preservation treatment. Cleaning process were performed independently or continuously. Composition of mineral substances in the waterlogged archaeological wood was almost same as the that of soil in which waterlogged archaeological woods were buried. In case of independent cleaning, tools cleaning efficiently removed the mineral substances on surface. Surface color become brighter after cleaning with EDTA. In contrast, deaeration and ultrasonic cleaning did not show any significant removal of mineral substances. In continuous cleaning process, tool cleaning as the first step treatment showed the same effect as shown in independent cleaning. Although deaeration as the second step cleaning did not remove the mineral substances, it could be assumed to contribute the infiltration of dimensional agents by homogenization of wood. EDTA treatment (the third step cleaning) removed the iron(Fe) and increased the whiteness of wood color. The ultrasonic treatment (the fourth step cleaning) removed the sodium(Na) remained after EDTA treatment and the fine mineral substances.

  • PDF

Physical Properties and Cleaning Ability of New Cleaning Agents Based on 2,2,2-trifluoroethanol (TFEA) (2,2,2-trifluoroethanol (TFEA)를 기초로한 세정제의 물성 및 세정성 영향 연구)

  • Cha, An Jung;Park, Ji Na;Kim, Honggon;Bae, Jae Heum
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.533-541
    • /
    • 2005
  • Non-aqueous cleaning agents were formulated with 2,2,2-trifluoroethanol (TFEA) and hydrofluoroether (HFE), and their physical properties and cleaning abilities were examined. TFEA-based aqueous cleaning agents were also formulated with nonionic surfactants, hydrotropes and builders, and their cleaning abilities were compared. Possibilities of these cleaning agents as substitutes for CFC-113 and 1,1,1-TCE were finally evaluated. In this work, fluxes, cutting oils, greases, and fluoric oils were selected as model contaminants for cleaning experiments. These contaminants have different properties of water-solubility or hydrophilicity, and fat-solubility or lypophilicity. Cleaning abilities of TFEA-based cleaning agents were analyzed and compared through the measurement of contaminant weight changes as a function of cleaning time, and their possibilities as alternative cleaning agents were evaluated. As a result, it was shown that TFEA and HFE-based non-aqueous cleaning agents have quite a good cleaning power for fluxes and fluorine soils but low one for greases. And TFEA-based agueous cleaning agents which consisted of nonionic surfactants, hydrotrope, and builders were very effective for cleaning fluxes and greases under certain formulation conditions. Thus, it was revealed that the TFEA-based cleaning agents were very effective for cleaning specific contaminants and can be used as substitutes for CFC-113 and 1,1,1-TCE in some industrial applications.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

Formulation of Alternative Non-Aqueous Cleaning Agents to Chlorofluorocarbon Compounds for Cleaning Flux, Solder and Grease (Flux, Solder 및 Grease 세정용 CFC 대체 비수계 세정제 배합 연구)

  • Jung, Young Woo;Lee, Ho Yeoul;Lee, Myoung Jin;Song, Ah Ram;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.250-258
    • /
    • 2006
  • CFC compounds such as CFC-113 and 1,1,1-TCE, etc. have been used in various industries due to their excellent chemical stability, thermodynamic characteristics, non-inflammability and anti-corrosiveness. However, in oder to protect the earth environment, "the Montreal Protocol on substances that deplete the ozone layer" was adopted in 1989 for prevention of production and utilization of these CFC compounds and alternative cleaning agent have been required in the industry. The objective of this study is to develop non-aqueous cleaning agents that do not require major change of cleaning system, have excellent cleaning efficiency, are favorable to the environment, are harmless to the human body, and are not generated corrosive materials. In this work, non-aqueous cleaning agents have been formulated with glycol ether series and paraffinic hydrocarbon series with siloxane, and their physical properties and cleaning efficiencies were analyzed and compared with those of regulated materials. As a result of physical properties measurement of the formulated cleaning agents, it is expected that they may have good penetration ability into contaminated materials due to their properties with low density and low surface tension. Measurement of flash point and vapor pressure of the cleaning agents will be helpful for evaluation of their safety and working environment. The experimental results of cleaning flux, solder and grease by the formulated cleaning agents show that their cleaning abilities of soils were good and that there were no residues on the substance after cleaning. Therefore, alternative cleaning agents which have equivalent cleaning ability to regulating materials, good penetration ability and low hazard to human body, have been developed in this work.

  • PDF

Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane (세라믹 막여과 정수처리 공정에서 유입수질 및 막여과유속이 막오염 형성에 미치는 영향)

  • Kang, Joon-Seok;Park, Seo-Gyeong;Lee, Jeong-Jun;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.77-87
    • /
    • 2018
  • In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than $5m^3/m^2{\cdot}day$. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.

A Study of Cleaning Method of Excavated Gold Brocade (출토 직금직물의 세척방법에 관한 연구)

  • Hong, Moon-Kyung;Lee, Mee-Sik
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.7
    • /
    • pp.1162-1174
    • /
    • 2010
  • Excavated gold brocade, often shows signs of serious damage and contamination from environmental factors such as exposure to soil or human remains. Therefore, most of the conservation procedures are focused on the consolidation of the gold thread and on cleaning with water or organic solvents. Indiscreet cleaning using solvents could damage the gold leaf, which identifies the features of fabric. There is a need to develop cleaning protocols appropriate for relics through the careful analysis of the condition of the relics. This study finds the appropriate cleaning method for the excavated gold brocade. Four different cleaning methods, vacuum cleaning, kneaded rubber eraser cleaning, immersion wet cleaning, and absorption wet cleaning were applied to the excavated gold brocade. The degree of cleaning and damage were examined depending on the cleaning methods, changes to the physical condition (before and after cleaning) were also analyzed through the surface observation. Although immersion cleaning showed the best cleaning result, this method had a risk of damage to the gold thread. Absorption wet cleaning safely eliminated the various soluble contaminants and the rotten smell of relics. Kneaded rubber eraser was suitable for the excavated gold brocade fabric because it can be applied to selective parts, intentionally excluding some sensitive parts such as the gold thread. The vacuum cleaning method required special attention because of a possibility of suctioning off loosely attached gold leaf. Dual cleaning, the kneaded rubber eraser cleaning, followed by the absorption cleaning was the most effective method to preserve and clean excavated gold brocade.

Cleaning System Design using Supper Heating Steam (과열 수증기를 이용한 세정 시스템 설계)

  • Cho, Do-Hyeoun
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.47-51
    • /
    • 2011
  • In this paper, we propose the cleaning process system to remove micro-particles, various impurities, unnecessary residues, etc. for liquid crystal display manufacturing processes. This system is structured with cleaning, rinse and drying process using the chemical cleaning of alkaline water and the physical cleaning of SHS(supper heating steam). And we shows cleaning effects of alkaline water and remove effects of SHS.

The Effect of Blood cleaning therapy for Blood Latate Concentration (청혈요법이 혈중젖산 농도에 미치는 영향)

  • Baek Seung-Ryong;Park Rae-Joon;Kim Tae-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.147-156
    • /
    • 1997
  • The purpose of this study is to determine the difference of reduction in lactic acid of blood in the course of time 1)whoa applying the blood cleaning therapy during recovery after anaerobic exercise, 2)when applying the massage during recovery after anaerobic exercise, and 3)while taking a rest during recovery after anaerobic exercise, respectively. The subject of this study consists of 30 men who are divided into three groups such as group 1(n=10) for the blood cleaning therapy, group 2(n=10) for the massage and group 3(n=10) for rest. The blood-gathering was performed over four times ; during rest, immediately after unaerobic exercise, and at 10 and 15 minutes during recovery. The results were summarized as fellows. 1. There was reduction in lactic acid when applying the blood cleaning therapy during recovery after anaerobic exercise. And remarkable differences were shown from immediately after exercise to at 10 and 15 minutes during recovery(p<0.01 and p<0.001, respectively). 2. There was also reduction in lactic acid when applying the massage during recovery after anaerobic exercise. No difference wan shown from immediately after exercise to at 10 minutes during recovery. However a remarkable difference was shown from immediately after exercise to at 15 minutes during recovery(p<0.05). 3. The rest group which took a rest during recovery after anaerobic exercise did not show any difference from immediately after exercise to at 10 and 15 minutes during recovery.

  • PDF