• Title/Summary/Keyword: Physical Capability

Search Result 470, Processing Time 0.021 seconds

A Comparative Study on the Impact Factors and Moderator of Incentives of Knowledge Transfer Process in Organizations -Focused on Nonprofit Organization and Profit Organization- (조직내 지식이전 프로세스의 영향요인과 인센티브의 조절효과에 관한 비교연구 - 비영리조직과 영리조직을 중심으로 -)

  • Kang, Ju-Seon;Ko, Yoon-Jung
    • Management & Information Systems Review
    • /
    • v.32 no.2
    • /
    • pp.259-287
    • /
    • 2013
  • This study is to comparate on impact factors and moderator of incentives of knowledge transfer between Nonprofit and Profit organization. In nonprofit organization, the results founded that individual information capability, quality of knowledge, and quality of construct were statistically significant in knowledge acquisition, informal communication and quality of construct were statistically significant knowledge sharing, and individual information capability, informal communication, quality of knowledge and quality of construct were statistically significant knowledge use. Also interactive effect of knowledge sharing and Psychological Physical incentive was statistically significant knowledge use. In profit organization, the results founded that individual information capability, informal communication, quality of knowledge, and quality of construct were statistically significant in knowledge acquisition, quality of knowledge and quality of construct were statistically significant knowledge sharing, and individual information capability, informal communication, and formal communication were statistically significant knowledge use. Also interactive effect of knowledge acquisition and Psychological Physical incentive was statistically significant knowledge use.

  • PDF

A Study of TRM and ATC Determination for Electricity Market Restructuring (전력산업 구조개편에 대비한 적정 TRM 및 ATC 결정에 관한 연구)

  • 이효상;최진규;신동준;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.129-134
    • /
    • 2004
  • The Available Transfer Capability (ATC) is defined as the measure of the transfer capability remaining in the physical transmission network for further commercial activity above already committed uses. The ATC determination s related with Total Transfer Capability (TTC) and two reliability margins-Transmission Reliability Capability (TRM) and Capacity Benefit Margin(CBM) The TRM is the component of ATC that accounts for uncertainties and safety margins. Also the TRM is the amount of transmission capability necessary to ensure that the interconnected network is secure under a reasonable range of uncertainties in system conditions. The CBM is the translation of generator capacity reserve margin determined by the Load Serving Entities. This paper describes a method for determining the TTC and TRM to calculate the ATC in the Bulk power system (HL II). TTC and TRM are calculated using Power Transfer Distribution Factor (PTDF). PTDF is implemented to find generation quantifies without violating system security and to identify the most limiting facilities in determining the network’s TTC. Reactive power is also considered to more accurate TTC calculation. TRM is calculated by alternative cases. CBM is calculated by LOLE. This paper compares ATC and TRM using suggested PTDF with using CPF. The method is illustrated using the IEEE 24 bus RTS (MRTS) in case study.

The Correlation between Motor Capacity, Capability, and Performance in Children with Cerebral Palsy (뇌성마비 아동의 능력, 수행능력, 수행 간 상관관계)

  • Kim, JangGon;Kim, TaeYoon
    • 재활복지
    • /
    • v.20 no.3
    • /
    • pp.125-139
    • /
    • 2016
  • The aim of this study was to distinguish 3 concepts(capacity, capability, and performance) for the motor activities of children with cerebral palsy(CP) and examinate relation between capacity(can do in a standardized environment), capability(can do in daily environment), and performance(does do in daily environment). Cross-sectional analysis with a assessment record of children with CP (n=40; 19males, 21 females; mean age 6y 6mo, SD 3y 8mo) was performed. Levels of severity according to the Gross Motor Function Classification System(GMFCS) included level1(13%), level2(10%), level3(43%), level 4(33%), and level 5(3%). Motor activities capacity was assessed by the Gross Motor Function Measure (GMFM-66). Capability and performance were assessed using 2 scales(functional skill, caregiver assistance) of the Pediatric Evaluation of Disability Inventory(PEDI). Correlations between capacity and capability was 0.811(p < .05), and between capability and performance were high(r=0.711, p < .05). And the correlation between capacity and performance is the lowest(r=0.711, p < .05). Motor performance levels are only partly reflected by the motor capacity and motor capability levels in children with CP. Because performance is influenced by Contextual factors (particularly, social factors such as family function). This study suggests that it is necessary to distinguish and evaluate the capacity, capability, and performance in children with cerebral palsy.

A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer (비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구)

  • Seon, Yun-Suk;Kim, Jin-Seong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

Development of Sound Isolation Sheets with Compound Materials (복합재료를 이용한 시트형 차음재 개발)

  • Lee, Dong-Hoon;Lee, Tae-Kun;Cheong, Seong-Kyun;Lee, Hee-Won;Kang, Moon;Kim, Young-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.415-420
    • /
    • 2000
  • This paper describes a part of the results obtained in the process of the development of thin sound isolation sheets filled mineral compound powder with PVC. The raw materials used are pyrophillite, pottery stone and graphite. The physical properties such as the crystal structures, compositions, and specific gravities, etc. of raw materials are analyzed and discussed from a point of view of sound isolation material. From the analysis of experimental results, the particle size and the additive amount of mineral compound powder for manufacturing sample isolation sheets are decided. The resistant capability against fire of sound isolation sheets including mechanical, thermal and physical properties is tested. The transmission loss measuremenst of sound isolation sheets are performed using two-microphone method in an impedance tube. It is shown that the sound isolation capability of thin sheets has an excellent performance in excess of the object of development.

  • PDF

Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors (백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법)

  • Gam, Kee-Sool;Yoo, Sung-Ho;Kim, Sung-Min;Lee, In-Sick
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.

Inter-comparison of temperature measurement capability using standard platinum resistance thermometers (표준백금저항온도계를 이용한 온도측정능력 상호비교)

  • Gam, K.S.;Kang, C.S.;Lee, Y.J.;Lee, K.B.;Kim, Y.G.;Park, S.N.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Development of Evaluation System for Aviation Mission Suitability Depending on Pilot's Alertness and Physiological Stability Level (조종사의 각성 및 생리적 안정에 근거한 비행임무적합 수준 판정 시스템의 개발)

  • Kim, Dongsoo;Lee, Wooil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.789-796
    • /
    • 2015
  • Fighter pilot's ability to maintain both mental and physical capabilities in highly stressful situations is important for aviation safety as well as mission performance because pilot may confront frequently unexpected physical and psychological stimulation. Cumulative psychological stress and physical fatigue can be causes of mood distortion, declined alertness, and can lead to reduction of combat capability. We have investigated bio-signals and performance tests to monitor stress and fatigue levels, and developed a system to evaluate aviation mission suitability before flight. This study elucidated that stress and fatigue level of pilot can be monitored by psychomotor cognitive test(PCT) and heart rate variability(HRV), and that the best of reference for aviation mission suitability was confidential interval obtained from cumulative data of individuals. The system to evaluate aviation mission suitability was constructed with measuring part with PCT and HRV and control part with DB and algorithm.

Relative Humidity Transducer Proficiency Test for KOLAS Humidity Calibration Laboratories (KOLAS 교정기관 간 측정 동등성 확립을 위한 상대습도 변환기 숙련도 시험)

  • Sang-Wook Lee;Young-Suk Lee;Byung-Il Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.447-454
    • /
    • 2023
  • The Korea Laboratory Accreditation Scheme (KOLAS) operates accreditation programs for ensuring measurement traceability with the International System (SI) of Units - the highest calibration standard that measurements can be tested against. As of September 2023, there are 70 KOLAS-accredited laboratories in the Republic of Korea that specialize in humidity calibration. Among them, 32 KOLAS laboratories, along with one laboratory not affiliated with KOLAS, participated in the proficiency test (PM 2023-11) for relative humidity transducers in 2023. This proficiency test was conducted within a relative humidity range of 20-90% at a temperature of approximately 20 ℃, taking into consideration the calibration and measurement capability (CMC) of the participating laboratories. The primary objective of the proficiency test was to establish the measurement equivalence between each participating laboratory and the reference laboratory, by calculating the number of equivalence (En). When |En| was less than 1, the measurements from the participating and reference laboratory were equivalent. Out of the 33 participating laboratories, 32 successfully met this criterion and passed the proficiency test.

The Effect of Technology Innovation Capability of Domestic Root Companies on Business Performance: Focusing on the Mediating Effect of Internal Resources (국내 뿌리기업의 기술혁신역량이 경영성과에 미치는 영향: 내부자원의 매개효과를 중심으로)

  • Seo, Sunyoung;Seo, Jonghyen
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.3
    • /
    • pp.90-103
    • /
    • 2022
  • The purpose of this study is first to understand whether technology innovation capability, which is considered an important factor in the Root companies, directly affects the business performance of the company. Second, it was attempted to determine whether internal resources deemed necessary for a company's continuous competitive advantage and excellent business performance play a mediating role in the technological innovation capability of the Root companies and the business performance. The implications of this study derived from the research results are as follows: Among the elements of technology innovation capability, R&D capability, positively affects both financial and non-financial performance. It was confirmed that the investment ratio could positively affect financial performance such as sales, market share, and yield, and non-financial performance such as corporate image, employee satisfaction, and productivity. Among the factors of technology innovation capability, the technology innovation system positively affects both financial and non-financial performance. Therefore, it can be said that securing rights to owned technology, establishing technology and funding, efficient use of resources, etc., affects financial performance such as sales or market share of a company, and affect the company's production capacity, image, and employee satisfaction. It has been verified that internal resources, including financial, physical, and human resources, can mediate between the three elements of technology innovation capability and corporate financial and non-financial performance.