• 제목/요약/키워드: Photovoltaic-thermal

검색결과 306건 처리시간 0.025초

실험을 통한 건물통합형 태양광·열(BIPVT) 시스템의 난방성능 평가 (The Heating Performance Evaluation of Heating System with Building-Integrated Photovoltaic/Thermal Collectors)

  • 정선옥;김진희;김지성;박세현;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.113-119
    • /
    • 2012
  • The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of PV module with a solar thermal collector which forms one device that produce thermal energy as well as electricity. In many studies various water type PVT collectors have been proposed in effort to increase their electrical and thermal efficiency. The aim of this study is to evaluate the heating performance of heating system combined with PVT collectors that on integrated building roof. For this study, the BIPVT system of 1.5kWp was installed at the experimental house, and it was incorporated with its heating system. From the experimental results, the solar fraction of the heating system with BIPVT was 15%. It was also found that was analyzed that the heating energy for the house can be reduced by 47%, as the heat gained from BIPVT system pre-heated the water used for heating system.

전면 액체식 흡열판을 적용한 PVT 모듈의 실험성능 (A Experimental Performance of PVT Module With Fully Wetted Absorber)

  • 천진아;김진희;김준태;조인수;남승백
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.121-126
    • /
    • 2011
  • The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of PV module with a solar thermal collector which forms one device that converts solar radiation into electricity and heat simultaneously. In general, there are two different types of PVT module: glazed PVT module and unglazed PVT module. On the other hand, two types of the PVT module can be distinguished according to absorber on PV module rear side: the sheet-and-tube absorber PVT module and the fully wetted absorber PVT module. In this paper, the experimental performance of water type unglazed PVT with fully wetted absorber was analyzed. The electrical and thermal performance of the unglazed PVT were measured in outdoor conditions, and the results were analyzed. The experimental results showed that the thermal efficiency of the PVT module was 42% average, and its electrical efficiencies were 15.2% and 14.2% average, respectively, for the mean fluid temperature of $10-20^{\circ}C$ and $21-30^{\circ}C$. Thermal efficiency depends on solar radiation, mean fluid temperature and ambient temperature. The PVT module temperature is related to the cooling effect of the PV module by the fluid of the absorber. The results proved that the electrical efficiency was higher when the mean fluid temperature was lower.

  • PDF

가혹조건에서의 태양전지모듈 내구성 평가를 통한 최적의 시험조건 제안 (Suggestion of Long-term Life Time Test for PV Module in Highly Stressed Conditions)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.63-68
    • /
    • 2010
  • To guarantee life time more than 20 years for manufacturer without stopping photovoltaic(PV) system, it is really important to test the module in realistic time and condition compared to outside weather. In here, we tested PV modules in highly stressed condition compared to IEC standards. In IEC 61215 and IEC 61646 standards, damp-heat, thermal cycle(TC200) and mechanical test are main test items for evaluating long-term durability of PV module in controlled temperature and humidity condition. So in this paper, we have lengthened the test time for TC200 and damp-heat test and increased the loading stress on surface of module. Through this test, we can get some clue of proper the method for measuring realistic life cycle of PV modules and suggested the minimum time for PV test method. The detail description is specified as the following paper.

유기물을 이용한 Photovoltaic cell의 광기전력 특성 (Photovoltaic Properties of Organic Photovoltaic cell)

  • 김상걸;이헌돈;정동회;오현석;홍재일;박종욱;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.123-126
    • /
    • 2003
  • Recently, there is a growing concern on the photovoltaic effects using organic materials. This is a phenomena which converts the solar energy into the electrical one. We have fabricated a device structure of $ITO/PEDOT:PSS/CuPc/C_{60}/BCP/AI$. The PEDOT:PSS layer is made by spin coating, and the other organic layers are made by thermal vapor deposition. By measuring the current-voltage characteristics with an illumination of light, we have obtained value of Voc=0.38V, Jsc=$0.5mA/cm^{2}$. And a fill factor and efficiency are about 0.314 and 0.083%, respectively. A 500W xenon lamp(ORIEL) is used for a light source, and the light intensity illuminated into the device was about 10mW.

  • PDF

Large Band Gap Attenuation of CdS Nanoclusters after H2S Exposure

  • Han, Seung-Woo;Park, Eun-Hye;Kang, Kwang-Sun
    • Current Photovoltaic Research
    • /
    • 제7권2호
    • /
    • pp.29-32
    • /
    • 2019
  • Large band gap attenuation of CdS nanoclusters in hybrid sol gel matrix comprised of 3-(trimethoxysilyl)propyl methacrylate (TMSPM), 15 wt. % zirconium, and various amounts of cadmium acetate was observed after $H_2S$ exposure. Hybrid sol gel matrixes were prepared by hydrolysis and condensation reactions. The sol gels contained with various amount of cadmium acetate were spin coated to glass substrates and exposed to $H_2S$ gas. The UV-visible absorption peaks were shifted toward blue with increasing the amount of CdS nanoclusters and were shifted to the red after thermal process. Significant amount of -OH absorption peaks were reduced after thermal process. Strong room temperature photoluminescence (PL) of CdS nanoclusters was observed after exposing to $H_2S$ gas. The PL intensity increased for several minutes and slowly decreased thereafter. The luminescence peaks were continuously shifted toward blue as the time passed. Extraordinary Stokes shift (approximately 160 nm) was observed.

열처리 방법에 따른 카본전극 페로브스카이트 태양전지의 특성 변화 (Properties of the carbon electrode perovskite solar cells with various annealing processes)

  • 송오성;김광배
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.26-32
    • /
    • 2021
  • 카본 전극 페로브스카이트 태양전지의 광활성층을 형성하는데 열판, 오븐, 쾌속열처리로 방법을 달리하며 이때 광전기적 특성과 미세구조 변화를 확인하였다. Glass/FTO/compact TiO2/meso TiO2/meso ZrO2/perovskite/carbon electrode 구조의 페로브스카이트 태양전지 소자를 열판 공정, 오븐 공정, RTA(rapid thermal annealing) 공정을 이용하여 준비하였다. 이때 광전기적 특성과 미세구조를 solar simulator와 광학현미경, 장발산주사전자현미경을 이용하여 각 소자의 특성을 분석하였다. 광전기적 특성 분석 결과, RTA 공정을 이용하여 제작한 소자에서 가장 우수한 광전기적 특성을 확인할 수 있었다. 미세구조 분석 결과 열판 공정과 오븐 공정으로 제작한 시편은 카본 전극 상부에 과잉 페로브스카이트 상이 형성되고, RTA 공정으로 제작한 시편에서는 시편 상부에 과잉 페로브스카이트 상 없이, 균일한 페로브스카이트가 형성된 것을 확인할 수 있었다. 또한 단면 미세구조에서는 RTA 공정으로 제작한 소자가 다공성 카본 전극 층에 고밀도의 페로브스카이트 층을 형성하여 우수한 광전기적 특성을 나타내었다. 따라서 대면적 소자 제작의 공정시간을 고려한 새로운 열처리방안으로 RTA 방법의 채용 가능성을 확인하였다.

스팬드럴 적용 BIPV의 후면 열 특성에 관한 연구 (A Study on the Thermal Characteristics of BIPV Applied on Curtain Wall Spandrel)

  • 이상길;강태우;장한빈;강기환;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.120-126
    • /
    • 2012
  • BIPV is applied to buildings in various forms. However, there are some aspects of consideration in applying PV systems in buildings, such as attaching methods, PV electrical efficiency, appearance and so on. BIPV can be installed on curtain wall spandrel as finishing material, which may combine with insulation. The thermal characteristic of spandrel with BIPV has rarely been studied; the temperature of air space between PV module and insulation layer affects both the electrical behavior of PV module and the energy load in a building. This paper aims to analyse the temperature variation of the layers in BIPV spandrels. In this paper, the temperature of layers, including the air space and PV module, was measured for three different type of BIPV applications on spandrel. The results show that the temperature of air layer for the spandrel with G/G(2) type BIPV module on October was the highest among other months.

공기식 집열 지붕 난방시스템의 실험 연구 (An Experimental Study of Solar fir Roof Heating System With PVT Collector)

  • 강준구;김진희;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

급속열처리장치 승온 조건에 따른 CIGS 박막 태양전지 특성 연구 (Characteristics of CIGS Thin Film Photovoltaic Cells with a Change of Rising-Temperature Time in Rapid Thermal Processing)

  • 정용민;박찬일;조금배
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.107-112
    • /
    • 2013
  • Cu(In,Ga)$Se_2$ (CIGS) thin films were annealed on molybdenium/sodalime glass substrates of $300{\times}300mm^2$ by rapid thermal processing (RTP) with 2-step rising-temperature times in $N_2$ ambient. Morphological property, structural characteristics and chemical composition of the precursor of CIGS thin films were influenced directly with a change of $1^{st}$-step rising-temperature time in RTP whereas there is no significant difference with the different $2^{nd}$-step rising-temperature time (final crystallization temperature). The shorter $1^{st}$-step rising-temperature time in RTP obtained the higher photovoltaic cell efficiency from 7.469% to 8.479% even though the ideal composition in CIGS thin films could not be accoplished in this study.

단열복합 구조에 따른 지붕일체형 태양전지모듈의 성능 분석 (Analysis of Roof Integrated Photovoltaic Module's Performance with Insulation Hybrid Structure Layer)

  • 강기환;김현일;박경은;유권종;이소미
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1220-1221
    • /
    • 2007
  • Building-integrated photovoltaic(BIPV) perform traditional architectural function of walls and roof while also generating electricity. But most of the absorbed solar energy appears passively as heat, raising the temperature of cells and reducing the efficiency with which the active part is converted into electricity. Therefore this paper presents the comparison of electrical, architectural and thermal performance of roof integrated photovoltaic(PV) modules, which is composed of different hybrid structure layer such as urethane form, waffle stud etc.

  • PDF