• 제목/요약/키워드: Photovoltaic current

검색결과 972건 처리시간 0.033초

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권2호
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

BCP를 엑시톤 억제층으로 사용한 유기 광기전력 소자의 특성 (Properties of the Exciton Blocking Layer with BCP in Organic Photovoltaic cell)

  • 오현석;이준웅;이원재;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.273-274
    • /
    • 2005
  • Photovoltaic effects in organic solar cell were studied in a cell configuration of ITO/PEDOT:PSS/CuPc(20nm)/$C_{60}$(40nm)/BCP/Al(150nm) at room temperature. Here, the BCP layer works as an exciton blocking layer. The exciton blocking layer must transport electrons from the acceptor layer to the metal cathode with minimal increase in the total cell series resistance and should absorb damage during cathode deposition. Therefore, a proper thickness of the exciton blocking layer is required for an optimized photovoltaic cell. Several thicknesses of BCP were made between $C_{60}$ and Al. And we obtained characteristic parameters such as short-circuit current, open-circuit voltage, and power conversion efficiency of the device under the illumination of AM 1.5.

  • PDF

복합 환경시험 순서에 따른 태양전지모듈의 특성 변화 (Performance Change of Crystalline Photovoltaic Module in Modified Test Sequence)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.23-24
    • /
    • 2011
  • In this paper, I performed the IEC test in crystalline photovoltaic module described in test standard. And sometimes I changed the test sequence and impact factors for testing modules. Comparing the current test trees in IEC 61215, some ideas are suggested in proper test sequence to guarantee the long-term durability for 25 years.. The detail discussion will be shown in the following paper.

  • PDF

Truncated DCPC를 이용한 저배율 태양광 모듈 개발 (Development of Low Concentrated Photovoltaic using a Truncated DCPC)

  • 이동길;김양규;이광훈;장원근;박영식
    • Current Photovoltaic Research
    • /
    • 제1권1호
    • /
    • pp.33-37
    • /
    • 2013
  • LCPV modules under 5 suns consist of reflective optics and receiver modules, similar to a typical fixed concentration PV module. If they are to be used as a compound parabolic concentrator, which is filled with a dielectric material, a compact plate structure of the fixed CPV can be designed and built at a large acceptance angle. These types of flat-$plate{\mu}$-LCPV modules are suitable for building integrated photovoltaic modules, facade applications, mobile devices, and small home appliances. Therefore, in this study, the possibilities for other application devices were studied and presented by designing and fabricating LCPCs for CPV modules.

온도보정계수를 고려한 태양광발전 운전특성연구 (A Study on Drive Characteristic of Photovoltaic to consider temperature compensation account.)

  • 이정일;윤정필;유희옥;윤형상;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2001
  • Photovoltaic System does military exploit that use heliometer light and is clearness source of energy. Photovoltatic System is no noise, shock among is several Substitute energy and after establishment maintenance having simple special quality, is applied in many fields. However, while Photovoltatic System is having these advantage, but react sensitively in effect of Photovoltaic scanning Quantity, temperature change etc.. surrounding environment, when did not satisfy condition, express indefinite output price. Consider voltage$\cdot$current output measurement value and temperature revision calculation by temperature change of existing photovoltaic system and change of output price of when did Simulation analyzed comparison.

  • PDF

수조식 양식장의 태양광발전시스템 리모델링 교체 효과: 시뮬레이션을 통한 에너지절감효과 분석 (The Effect of Remodeling Replacement of Photovoltaic Power Generation System in Fish Farm : Analysis of Energy Saving Effect through Simulation)

  • 최현석;나종혁;이현영;노재엽
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2021
  • In the past, marine pollution caused by radioactivity and wastewater discharge caused mass destruction. As an alternative, the land farming system became common and operational. In recent years, safety and environmental problems caused by declining population due to aging of fishermen and underdeveloped facilities have always been lurking, so improvement is urgently needed. As part of the new renewable energy 3020 plan announced by the government in 2017, a new model was proposed to improve the environment as well as save energy when the roof of a water tank farm was remodeled into a solar power system. Study, when the existing roof was remodeled and replaced with a water tank farm in Busan as an empirical model, the energy saving rate was analyzed by comparing the actual electricity consumption and power generation.

A Brief Review on Variables and Test Priorities of Photovoltaic Module Life Expectancy

  • Padi, Siva Parvathi;Chowdhury, Sanchari;Zahid, Muhammad Aleem;Kim, Jaeun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.36-44
    • /
    • 2021
  • To endorse the reliability and durability of the solar photovoltaic (PV) device several tests were conducted before exposing to the outdoor field in a non-ideal condition. The PV module has high probability that intend to perform adequately for 30 years under operating conditions. To evaluate the long term performance of the PV module in diversified terrestrial conditions, one should use the outdoor performance data. However, no one wants to wait for 25 years to determine the module reliability. The accelerating stress tests performing in the laboratory by mimicking different field conditions are thus important to understand the performance of a PV module. In this review, we will discuss briefly about different accelerating stress types, levels and prioritization that are used to evaluate the PV module reliability and durability before using them in real field.

태양광 접속반의 자동 화재 예방 및 진압 시스템 설계 (Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module)

  • 이강원;양오
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

Current Sensorless MPPT Control Method for Dual-Mode PV Module-Type Interleaved Flyback Inverters

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.54-64
    • /
    • 2015
  • This paper presents a current sensorless maximum power point tracking (MPPT) control method for dual-mode photovoltaic (PV) module-type interleaved flyback inverters (ILFIs). This system, called the MIC (Module Integrated Converter), has been recently studied in small PV power generation systems. Because the MIC is an inverter connected to one or two PV arrays, the power system is not affected by problems with other inverters. However, since the each PV array requires an inverter, there is a disadvantage that the initial installation cost is increased. To overcome this disadvantage, this paper uses a flyback inverter topology. A flyback inverter topology has an advantage in terms of cost because it uses fewer parts than the other transformer inverter topologies. The MPPT control method is essential in PV power generation systems. For the MPPT control method, expensive dc voltage and current sensors are used in the MIC system. In this paper, a MPPT control method without current sensor where the input current is calculated by a simple equation is proposed. This paper also deals with dual-mode control. Simulations and experiments are carried out to verify the performance and effectiveness of the proposed current sensorless MPPT control method on a 110 [W] prototype.

양면형 태양광발전 소자의 성능변수 및 이에 대한 정확한 측정방법 (Performance Parameters of a Bifacial PV Device and Accurate Measurement Method for the Parameters)

  • 안승규;안세진;어영주;유진수;박주형;김기환;조아라;조준식;윤재호;신동협;정인영;곽지혜
    • Current Photovoltaic Research
    • /
    • 제5권3호
    • /
    • pp.89-94
    • /
    • 2017
  • We have examined the issues on the measurement of bifacial photovoltaic(PV) devices that should be considered in order to ensure a measurement accuracy beyond a certain level and the comparability between the bifacial PV devices. Based on the results of various experiments and previous studies, solutions for these measurement issues are suggested. The most significant technical issues in the performance measurement of the bifacial PV devices are 1) elimination of the effect due to the light reflection on the sample holder surface and 2) the measurement of the expected power generation gain in outdoor operation. The effect due to the light reflection on the sample holder surface can be eliminated by using an anti-reflective sample holder. In case of a reflective sample holder, if the bifacial device have a linear characteristic with respect to the irradiance of incident light, it has been confirmed (through some previous studies and additional experiment) that exact measurement results can be obtained by the correction of the measurement data. In addition, it was also confirmed that the expected power generation gain in the outdoor operation can be obtained by three different methods along with the basic concepts of the bifaciality coefficient, the albedo, and the effective front irradiance.