• Title/Summary/Keyword: Photovoltaic arrays

Search Result 85, Processing Time 0.03 seconds

Improvement of generation capacity per unit site area by the optimization of photovoltaic array (태양광어레이 최적화에 의한 단위 부지면적당 발전량 개선)

  • Kim, Eui Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.109.2-109.2
    • /
    • 2011
  • A photovoltaic system is getting the spotlight for a environment-friendly energy source. But its location is limited because a lot of land is necessary for photovoltaic arrays. Nevertheless, its dissemination is rapidly increasing more than 40 % every year and exceeded about 400 MW in 2009. The radical growth of a photovoltaic system aggravated a lack of sites, so that forests and farmland were destroyed. It is demanded to make use of a vacant lot or little piece of land for the way to solve the lack of sites and improve the location requirements for a photovoltaic system. General photovoltaic arrays are consist of a single layer structure and needs enough separation distances to maximize the amount of solar radiation and to eliminate influences by the shadow of other arrays. So that a large amount of land is required for the site. The solar cell arrays with long separation distances can not be placed in a small vacant lot and its site application efficiency is low. This study optimized photovoltaic arrays as multilayered structure with movable sleeves for the efficient photovoltaic in a small site. The existing photovoltaic arrays with a single layer structure were fixed or tracking systems. In this experimental equipment, photovoltaic arrays attached to the multilayers have rectilinear movement and rotary motion using sleeves. Therefore, shadow influences were removed and the generation capacity was improved. On the simulation result, generation increased by about 30% in the same site considering shadow influences and so on.

  • PDF

Fault Location Diagnosis of Photovoltaic Power Arrays (태양광 어레이의 고장 위치 진단 기법)

  • Lee, Sang Jun;Lee, Roo Da;Cho, Hyun Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.81-82
    • /
    • 2015
  • Recently, fault detection and diagnosis techniques have been significantly considered to reduce possible economic loss due to faulty in photovoltaic power systems. This paper presents a new fault location diagnosis method for photovoltaic power systems. The proposed algorithm compares the output voltage generated from a photovoltaic array to the outputs of its neighboring arrays. This concept is realized by obtaining error voltages among all arrays, which are simply defined by deviation between its neighboring arrays. We accomplish a real-time experiment to demonstrate reliability of the proposed fault location diagnosis by using a 60W photovoltaic power system test-bed.

  • PDF

The Study on Optimum Installation angle of Photovoltaic Arrays using the Expert System (전문가시스템을 이용한 태양광 어레이의 최적설치 각도에 관한 연구)

  • Yu, Gwon-Jong;Lee, Yo-Han;So, Jung-Hun;Seong, Se-Jin;Yu, Byung-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.107-115
    • /
    • 2007
  • The measured solar radiation incident on tilted surfaces has been widely used as important solar radiation data in installing photovoltaic arrays. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar photovoltaic systems. This is because the performance of the solar photovoltaic systems is much affected by angle and direction of incident rays. The expert system can predict the optimum installation angle of photovoltaic arrays with those factors.

Improved Global Maximum Power Point Tracking Technique Using Output Characteristics of Solar Array (태양광 어레이의 출력 특성을 이용한 개선된 전역 최대전력 점 추종 기법)

  • Yoo, Koo-Hyun;Lee, Woo-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2020
  • The photovoltaic module has the characteristic that the output power varies according to the amount of insolation. If partial shading occurs in an environment composed of an array, a number of local maximum power points (LMPPs) may be generated according to the shading state. Photovoltaic arrays require global maximum power point tracking due to variations in output characteristics caused by solar radiation and temperature. Conventional algorithms, such as P&O and Incond, do not follow the global maximum power point in a partial shaded solar array. In this study, we propose a technique to follow the global maximum power point by using the correlation of voltage, current, and power in solar arrays. The proposed control technique 2qw validated through simulation and experiments by constructing a 2-kW solar system.

Characteristic Analysis of Building Integrated Photovoltaic System (건물일체형 태양광발전시스템의 특성 분석)

  • Kang, Gi-Hwan;So, Jung-Hun;Park, Kyung-Eun;Kim, Hyun-Il;Yu, Gwon-Jong;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1672-1674
    • /
    • 2005
  • The PV arrays were designed as sunshade devices at the building in the KIER(Korea Institute of Energy Research). The arrays are shaded by the above placed devices. In this paper, it was analyzed that the performance and characteristic of the BIPV system by partial shading could reliably be calculated with Solar Pro.

  • PDF

The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array (태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구)

  • Park, Yu-Na;Jang, Gil-Soo;Ko, Suk-Whan;Kang, Gi-Hwan;So, Jung-hun;Jung, Young-Seok;Ju, Young-Chul;Hwang, Hye-Mi;Song, Hyung-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.

Optical Characteristics of Nanocone-patterned c-Si Wafers Coated with Dielectric Thin Films (유전박막이 도포된 나노원뿔 패턴된 단결정 Si 기판의 광특성)

  • Kim, Eunah;Park, Jimin;Ko, Eun-Ji;Kim, Dong-Wook
    • Current Photovoltaic Research
    • /
    • v.5 no.2
    • /
    • pp.55-58
    • /
    • 2017
  • We investigated the influences of dielectric thin film coating on the optical characteristics of c-Si wafers with nanocone (NC) arrays using finite-difference time-domain (FDTD) simulations. Dielectric thin films on high-refractive-index surface can lower optical reflection and reflection dips appear at the wavelengths where destructive interference occurs. The optical reflection of the NC arrays was lower than that of the dielectric-coated planar wafer in broad wavelength range. Remarkable antireflection effects of the NC array could be attributed to beneficial roles of the NCs, including the graded refractive index, multiple reflection, diffraction, and Mie resonance. Dielectric thin films modified the optical reflection spectra of the NC arrays, which could not be explained by the interference alone. The optical properties of the dielectric-coated NC arrays were determined by the inherent optical characteristics of the NC arrays.

Photovoltaic Behavior of Dye-sensitized Long TiO2 Nanotube Arrays

  • Kim, Sang-Mo;Kim, Hark-Jin;Kim, Yong-Joo;Lim, Goo-Il;Choi, Young-Sik;Lee, Wan-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.4035-4040
    • /
    • 2011
  • Long $TiO_2$ nanotube (NT) arrays, prepared by electrochemical anodization of Ti foils, have been utilized as dye-adsorbing electrodes in dye-sensitized solar cells (DSCs). By anodizing for 1-24 hr and subsequent annealing, highly crystallized and tightly-adhered NT arrays were tailored to 11-150 ${\mu}m$ lengths, ~90 nm innerpore diameter and ~30 nm wall thickness. I-V curves revealed that the photovoltaic conversion efficiency (${\eta}$) was proportional to the NT length up to 36 ${\mu}m$. Beyond this length, the ) was proportional to the NT length up to ${\eta}$ was still steadily increased, though at a much lower rate. For example, an ${\eta}$ of 5.05% at 36 ${\mu}m$ was increased to 6.18% at 150 ${\mu}m$. Transient photoelectron spectroscopic analyses indicated that NT array-based DSCs revealed considerably higher electron diffusion coefficient ($D_e$) and life time (${\tau}_e$) than those with $TiO_2$ nanoparticles (NP). Moreover, the electron diffusion lengths ($L_e$) of the photo-injected electrons were considerably larger than the corresponding NT lengths in all the cases, suggesting that electron transport in NT arrays is highly efficient, regardless of tube length.

Maximum Efficiency Point Tracking Control Algorithm for Improving Electric Power Transmission Efficiency between Photovoltaic Power Generating system and the Grid (태양광발전시스템과 계통간의 전력 전송 효율 개선을 위한 최대효율점 추적 제어 알고리즘)

  • Kwon, Cheol-Soon;Kim, Kwang Soo;Do, Tae Young;Park, Sung-Jun;Kang, Feel-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • It proposes an efficient control algorithm to increase electric power transmission efficiency between photovoltaic power generating system and the grid. The main controller finds a maximum efficiency condition by considering the quantity of power generated from PV arrays, the number of inverters, and efficiency of PV inverter. According to the condition, a relay board arranges a point of contract of PV arrays. By the disposition of PV arrays, it assigns the optimized power on each PV inverter. Operational principle of the proposed maximum efficiency point tracking algorithm is given in detail. To verify the validity of the proposed approach, computer-aided simulation and experiment carried out.

Fabrication of Conducting Polymer Nanowires using Block Copolymer Nano-porous Templates for Photovoltaic Device

  • Lee, Jeong-In;Yu Jae-Woong;Kim, Jin-Kon;Russell Thomas P.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.312-312
    • /
    • 2006
  • Block copolymers with well-defined nanoscopic structures have recently gained much attention for their potential uses as functional nanostructures. Here, we show that nanoporous templates made from polystyrene-block-poly (methyl methacrylate) (PS-b-PMMA) satisfy a novel design concept. At first, arrays of nanoscopic cylindrical microdomains oriented normal to the surface can easily be prepared. Then, we fabricated ultra high density arrays of conducting polymer as poly(pyrrole) (Ppy) and poly(3,4-ethylenedioxythiophene) (PEDOT) nanowires with diameters of $25{\sim}40\;nm$ on the ITO glass by electropolymerization of the monomers inside nanoholes. These high density arrays of conducting polymer nanowires could be used as P-type materials for photovoltaic devices.

  • PDF