• Title/Summary/Keyword: Photovoltaic array

검색결과 289건 처리시간 0.042초

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1687-1688
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that tan occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

새로운 태양전지 모델을 이용한 태양전지 가상구현 시스템 (Virtual-Implemented Solar Cell System with New Cell Model)

  • 정병환;이상용;오방원;전윤석;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1374-1376
    • /
    • 2003
  • The output of solar cell or array depends on the weather conditions such as cell temperature and insolation level. If the output of the photovoltaic system would be regularly generated under any weather conditions, it is so easy to develop the inverter, its related system, and also control algorithm. This can be performed by the VISC(virtual-implemented solar cell) system studied in this paper. And a few I-V curves are provided by the manufacturers, and so any I-V value between the given curves is unknown. The new model for solar cell is proposed which is based on the interpolation. Both simulation and experiment are executed to show the validity of the proposed VISC system.

  • PDF

아치형 태양전지 어레이의 출력특성 분석 (The Operating Performance Analysis of PV Array for Arch Type)

  • 박정국;최연옥;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.240-241
    • /
    • 2009
  • 본 논문에서는 다양한 아치형 태양광발전(Photovoltaic : PV) 시스템을 시뮬레이션을 통하여 구성하고 그 운전특성을 최적의 경사각을 가지는 일정 경사각 PV 시스템과 비교 분석하였다. 결과 아치형 PV 시스템의 경우 모두 PV 어레이 경사각이 $30^{\circ}$인 일정 경사형 시스템에 비하여 9% 이상의 큰 차이가 남을 알 수 있었으며, 최적의 아치경사각은 $10^{\circ}\sim30^{\circ}$임을 알 수 있었다.

  • PDF

계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터 (High-Frequency DC Link Inverter for Grid-connected PV System)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

태양광 패널의 등가회로 모델링 알고리즘 개선 (Improved Parameter Extraction Algorithm for Photovoltaic Array Circuit Model)

  • 박준영;최성진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.369-370
    • /
    • 2014
  • 태양광 PCS개발과정에서는 온도나 방사량 등을 변화시키며 태양전지 패널의 I-V곡선을 모사할 수 있는 태양광 시뮬레이션 모델이 필요하다. 이러한 용도로 볼 때 특히 다이오드 기반의 등가회로 모델은 물리적인 성질을 바탕으로 태양광 패널의 특성을 비교적 정확히 설명할 수 있으나 특유의 비선형성으로 인하여 복잡한 회로 모델 파라미터 추출 기법을 필요로 한다. 본 논문에서는데이터 시트값에 기반한 새로운 태양광 패널 회로 모델링 알고리즘을 제안한다. 제안한 방법의 성능을 검증하기 위해 단결정 태양광 패널의 실제 데이터를 기반으로 최대전력점 ${\pm}10%$부근의 전류오차 적분값을 기준으로 기존 방법과 정확도를 비교한 결과 20%의 정확도 개선을 얻었다.

  • PDF

태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법 (An Adaptive Maximum Power Point Tracking Scheme Based on a Variable Scaling Factor for Photovoltaic Systems)

  • 이귀준;현동석;김래영;임춘호;김우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.435-436
    • /
    • 2012
  • 본 논문은 가변 조정계수를 이용한 적응형 MPPT 제어 기법을 제안한다. MPPT 제어 루프가 소신호 모델링을 통해 구성되며, PV array 의 동작점에 상관없이 MPPT 제어의 성능을 일정하게 유지하기 위한 가변 조정계수가 결정된다. 가변 조정계수는 오차에 대한 근사화된 곡선맞춤 다항식을 통해 결정되며, 이를 통해 사용자가 원하는 MPPT 의 동특성과 안정성을 전 MPPT 영역에 걸쳐 확보할 수 있다. 제안된 MPPT 기법의 타당성은 3KW 급 시스템에 대한 실험을 통해 검증한다.

  • PDF

독립형 태양광 발전시스템의 MPPT 제어기법 특성비교 (Comparison of MPPT Control Method Characteristic for Stand-alone PV System)

  • 이용식;김남인;정성원;김재현
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.75-79
    • /
    • 2012
  • Maximum power point tracking(MPPT) techniques are used in photovoltaic systems to maximize the PV array output power by tracking continuously the maximum power point which depends on panels temperature and on irradiance conditions. This paper proposes a variable step size MPPT algorithm which can improve the MPPT speed and accuracy. Depending on insolation and temperature, the MPPT controller gives optimized step size. The effectiveness of the proposed system is verified thorough PSIM simulation and experiments on a 50[W] prototype. The experimental results confirm that the PV power of the improved P&O method is higher than that of the traditional P&O method.

가정용 10kWh 배터리 에너지 저장 시스템 (Residential 10kWh Battery Energy Storage System)

  • 송인범;정두용;김동성;이수원;서광덕;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.224-225
    • /
    • 2010
  • This paper proposes a battery energy storage system using a photovoltaic generation system. The proposed system consists of a grid, battery and PV array. Considering a daily load profile, radiation and battery, operation modes are divided. An algorithm is presented based on modes. In the paper, operation modes and algorithms are verified through simulations.

  • PDF

축전지 사용 유무에 따른 태양광발전기의 성능 분석 (Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge)

  • 윤성욱;최만권;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.220-227
    • /
    • 2013
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 태양광발전시스템을 온실에 인접한 건물의 옥상에 설치하여 일사량에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 수평면 일사량의 최대, 평균 및 최소값은 각각 $26.1MJ{\cdot}m^{-2}$, $14.0MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 일일 전력량은 각각 약 6.1kWh, 3.7kWh 및 0.01kWh 이었다. 그리고 누계 일사량과 전력량은 각각 약 $4,378.2MJ{\cdot}m^{-2}$ 및 1,163.2kWh 정도이었다. 그리고 부하에 의해 소비된 적산전력량의 최대, 평균 및 최소값은 각각 4.5kWh, 2.4kWh 및 0.0kWh 정도이었고, 누계전력량은 739.2kWh 정도로서 발생 전력량의 약 63.5%에 해당하였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 어레이 표면온도가 상대적으로 높아지면 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 두 인자 간에 상관계수는 0.851 정도로서 상관관계가 높은 것으로 나타났다.

태양전지 모듈의 발전량 분석 장치 개발에 관한 연구 (A Study on Development of Power Analysing Device for PV Module)

  • 문채주;곽승훈;장영학;김태곤;김의선;김태현
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.