• 제목/요약/키워드: Photovoltaic Module, Solar Cell Module

검색결과 223건 처리시간 0.03초

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

모듈온도에 따른 전압-전력 특성 (P-V Characteristics According to the Module Temperature)

  • 홍정희;황준원;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2148_2149
    • /
    • 2009
  • Development of renewable energy is promoted to achieve sustainability. So researchers are seeking and developing a new, clean, safe and renewable energy. However, solar energy is an extreme intermittent and inconstant energy source. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC power vary with module temperature, it is necessary to study the characteristics of photovoltaic P-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic P-V according to the module temperature. The results show that it seems that when the module temperature increases, the DC power increases. But actually, because when the irradiation increases, the DC power increases, the result of the relationship between DC power and the module temperature of solar cell will be effects by the increasing irradiation.

  • PDF

복합 환경시험 순서에 따른 태양전지모듈의 특성 변화 (Performance Change of Crystalline Photovoltaic Module in Modified Test Sequence)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.23-24
    • /
    • 2011
  • In this paper, I performed the IEC test in crystalline photovoltaic module described in test standard. And sometimes I changed the test sequence and impact factors for testing modules. Comparing the current test trees in IEC 61215, some ideas are suggested in proper test sequence to guarantee the long-term durability for 25 years.. The detail discussion will be shown in the following paper.

  • PDF

염료감응 태양전지 모듈의 장기안정성 향상을 위한 실링기술 연구 (The Effect of Sealing Technology on the Long-Term Stability of Dye-Sensitized Solar Cell Module)

  • 이광수;고민재
    • Current Photovoltaic Research
    • /
    • 제4권4호
    • /
    • pp.155-158
    • /
    • 2016
  • Long-term stability of dye-sensitized solar cell (DSSC) module is critical for the commercialization. We investigated the effect of sealing technology on the long-term stability of the $10cm{\times}11cm$ sized DSSC modules. We applied the concept of secondary sealing to the module and then performed several stability tests such as humidity cycle, 1 sun light soaking and outdoor stability tests. The enhanced stability was confirmed for the DSSC module employing optimized sealing materials and architectures.

PV모듈의 전면 하중 기계강도 특성 (The mechanical strength characteristic on front-load of PV module)

  • 최주호;김경수;강기환;유권종;김일수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.164-168
    • /
    • 2011
  • This study of PV modules in the external environment, learn about the mechanical strength characteristics, the module will investigate the aluminum frame. Positive support in the module by wind loads if uniformly distributed load acting on the front glass of the module size and elongation(${\omega}$), and accordingly, depending on the bend is sealed inside the solar cell, micro-cracks that will occur. At this point the most damage-prone parts in a module, this module is part of the center of a strong wind load is applied by the destruction of the environment does not occur in the module frame to secure the reliability and to evaluate changes in the structure.

  • PDF

결정질 태양전지 모듈 내부 저항의 Missmatch 분석 (The Analysis of missmatch with resistance on Si-PV module)

  • 지양근;공지현;강기환;유권종;원창섭;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

반사판을 이용한 저집속 집광형 태양광 모듈 제작 및 평가 (Fabrication and Evaluation of Low Concentrator Photovoltaic Modules with Aluminium Reflectors)

  • 정혜정;이영우;주성민;이호재;부성재
    • 신재생에너지
    • /
    • 제4권4호
    • /
    • pp.17-22
    • /
    • 2008
  • A low concentrating (< 5X) photovoltaic module with aluminum reflectors is fabricated and evaluated which is designed to reduce the affection of the high temperature to the solar cell modules preventing the efficiency lowering. As results, the output power is increased of 1.97X from the concentrating photovoltaic module which is designed with the concentrating ratio of 2.25X and to control the module temperature cooling the module by air circulation. Also, the effect of the concentrating module with aluminum reflectors on the conventional PV module is investigated at the field. The result shows the increase of the output power more than about 20% and the improvement of the module efficiency of 1.4X in spite of the increase of average module temperature.

  • PDF

Characteristics of Photovoltaic I-V According to the Module Temperature

  • Lee, Ying;Choi, Yong-Sung;Zhang, You-Sai;Hwang, Jong-Sun;Lee, Kyung-Sup
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2101.1_2102.1
    • /
    • 2009
  • Solar energy is an extreme intermittent and inconstant energy source. This paper presents the analysis of photovoltaic I-V characteristics according to the module temperature. It shows that the result of the relationship between DC current and the module temperature of solar cell will be effects by the increasing irradiation.

  • PDF

수상태양광발전시스템의 출력 특성 분석에 관한 연구 (A Study on the Analysis of the Output Characteristics of the Floating Photovoltaic System)

  • 최원용;이재형;좌성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권5호
    • /
    • pp.312-317
    • /
    • 2017
  • In this paper, the effects of environmental variables on the output of the floating photovoltaic water systems, which were installed at the Hapcheon dam in South Korea, were investigated, and the correlations between them were analyzed. The system output was linearly proportional to the solar radiation or irradiance. The output was large in spring and autumn because of high irradiance, but low in the summer when the solar module temperature was high. The influence of the module temperature on the system output was limited in the summer, during which the module temperature change affected the system output more than the change of the irradiance did. In addition, in winter and summer, the module temperature tended to decrease with increasing windspeed, but windspeed did not affect module temperature significantly in the spring and autumn. On the other hand, in winter and spring, the irradiance decreased as the windspeed increased because of movement (or circulation) of the photovoltaic modules.