• 제목/요약/키워드: Photovoltaic Module, Solar Cell Module

검색결과 223건 처리시간 0.028초

다양한 환경조건에서 태양전지모듈의 PID회복특성 (PID Recovery Characteristics of Photovoltaic Modules in Various Environmental Conditions)

  • 이은석;정태희;고석환;주영철;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.57-65
    • /
    • 2015
  • The Potential Induced Degradation(PID) in PV module mainly affected by various performance conditions such as a potential difference between solar cell and frame, ambient temperature and relative humidity. The positive charges as sodium ions in front glass reach solar cell in module by a potential difference and are accumulated in the solar cell. The ions accelerate the recombination of generation electrons within solar cell under illumination, which reduces the entire output of module. Recently, it was generally known that PID generation is suppressed by controlling the thickness of SiNx AR coating layer on solar cell or using Sodium-free glass and high resistivity encapsulant. However, recovery effects for module with PID are required, because those methods permanently prevent generating PID of module. PID recovery method that voltage reversely applies between solar cell and frame contract to PID generation begins to receive attention. In this paper, PID recovery tests by using voltage under various outdoor conditions as humidity, temperature, voltage are conducted to effectively mitigate PID in module. We confirm that this recovery method perfectly eliminates PID of solar cell according to repeative PID generation and recovery as well as the applied voltage of three factors mainly affect PID recovery.

대면적 양면 태양광 모듈의 기계적 신뢰성 연구 (A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules)

  • 노요한;유장원;이재형
    • Current Photovoltaic Research
    • /
    • 제10권4호
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

PV모듈에서 그림자에 의한 전기적 특성 (The Electrical Characteristics of Shading Effect in Photovoltaic Module)

  • 김승태;강기환;박지홍;안형근;유권종;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.257-262
    • /
    • 2008
  • In this paper, we study the electric characteristics of shading effects in photovoltaic module in case of outdoor operation. When fabricating PV module, solar cells are connected serially to obtain the high voltage because of its low open circuit voltage. And total current is determined by lowest current among solar cells. When the shading happens on PV module's surface, the current of shaded solar cell determine the total current flow. Because of this, generally by-pass diode is installed on junction box. The bypass diode operate when revered and shaded solar cell's voltage is over 0.6 voltage. The reverse-biased solar cell gives reduced maximum power of PV module and might give negative effect on durability. So, adequate by-pass installation and selection is needed.

  • PDF

가로세로 폭의 제어가 가능한 슁글드 디자인 태양광 모듈 제조 (Fabrication of Shingled Design Solar Module with Controllable Horizontal and Vertical Width)

  • 박민준;김민섭;이은비;김유진;정채환
    • Current Photovoltaic Research
    • /
    • 제11권3호
    • /
    • pp.75-78
    • /
    • 2023
  • Recently, the installation of photovoltaic modules in urban areas has been increasing. In particular, the demand for solar modules installed in a limited space is increasing. However, since the crystalline silicon solar module's size is proportional to the solar cell's size, it is difficult to manufacture a module that can be installed in a limited area. In this study, we fabricated a solar module with a shingled design that can control horizontal and vertical width using a bi-directional laser scribing method. We fabricated a string cell with a width of 1/5 compared to the existing shingled design string cells using a bi-directional laser scribing method, and we fabricated a solar module by connecting three strings in parallel. Finally, we achieved a conversion power of 5.521 W at a 103 mm × 320 mm area.

PV모듈의 cell crack 방지를 위한 EVA Sheet의 최적 Gel content 특성 (The Optimimum Gel Content Characteristics for Cell Cracks Prevention in PV Module)

  • 강경찬;강기환;김경수;허창수;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1108-1109
    • /
    • 2008
  • To survive in outdoor environments, photovoltaic modules rely on packaging materials to provide requisite durability. We analyzed the properties of encapsulant materials that are important for photovoltaic module packaging. Recently, the thickness of solar cell gets thinner to reduce the quantity of silicon. And the reduced thickness make it easy to be broken while PV module fabrication process. Solar cell's micro cracks are increasing the breakage risk over the whole value chain from the wafer to the finished module, because the wafer or cell is exposed to tensile stress during handling and processing. This phenomenon might make PV module's maximum power and durability down. So, when using thin solar cell for PV module fabrication, it is needed to optimize the material and fabrication condition which is quite different from normal thick solar cell process. Normally, gel-content of EVA sheet should be higher than 80% so PV module has long term durability. But high gel-content characteristic might cause micro-crack on solar cell. In this experiment, we fabricated several specimen by varying curing temperature and time condition. And from the gel-content measurement, we figure the best fabrication condition. Also we examine the crack generation phenomenon during experiment.

  • PDF

Shingled 모듈 적용을 위한 태양전지 전극 구조 최적화 (Optimization of Solar Cell Electrode Structure for Shingled Module)

  • 오원제;박지수;황수현;이수호;정채환;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.290-294
    • /
    • 2018
  • The shingled photovoltaic module can be produced by joining divided solar cells into a string of busbarless structure and arranging them in series and parallel to produce a module, in order to produce a high output per unit area. This paper reports a study to optimize solar cell electrode structure for shingled photovoltaic module fabrication. The characteristics of each electrode structure were analyzed according to the simulation program as follow: 80.62% fill factor in the six-junction solar cell electrode structure and 19.23% efficiency in the five-junction electrode structure. Therefore, the split electrode structure optimized for high-density and high-output shingled module fabrication is the five-junction solar cell electrode structure.

백시트 종류에 따른 태양전지 모듈의 방열 특성 평가 (Evaluation of Heat Transfer Characteristics of PV Module with Different Backsheet)

  • 배수현;오원욱;강윤묵;이해석;김동환
    • Current Photovoltaic Research
    • /
    • 제6권2호
    • /
    • pp.39-42
    • /
    • 2018
  • When the PV module is illuminated in a high temperature region, solar cells are also exposed to the high temperature external environment. The operating temperature of the solar cell inside the module is increased, which causes the power drops. Various efforts have been made to reduce the operating temperature and compensate the power of solar cells according to the outdoor temperature such as installing of a cooling system. Researches have been also reported to lower the operating temperature of solar cells by improving the heat dissipation properties of the backsheet. In this study, we conducted a test to measure the internal temperature of each module components and the external temperature when the light was irradiated according to the surrounding temperature. Backsheets with different thermal conductivities were compared in the test. Finally, in order to explain the temperature difference between the solar cell and the outside of the module, we proposed an evaluation method of the heat transfer characteristics of photovoltaic modules with different backsheet.

기계적 스트레스에 의한 태양전지모듈의 전기적 특성변화 (The Variation of Electrical Characteristics of PV Module due to Mechanical Stress)

  • 공지현;지양근;강기환;김경수;유권종;안형근;한득영
    • 신재생에너지
    • /
    • 제6권1호
    • /
    • pp.38-45
    • /
    • 2010
  • Abstract Under the physical stress on photovoltaic (PV) module, it will be warped according to elongation of the front glass and then micro-crack will be occurred in the thermally sealed solar cell. This micro-crack leads to drop of short circuit current of the PV module. This is because of increase of resistance component by micro-crack. Micro-crack at specific solar cell in the module lessens the durability of PV module with reduced output, hot-spot caused by solar cell output mismatch and increased resistance component. This study shows the relation between electrical characteristics and micro- cracks due to mechanical stress on PV module.

PV의 건축물 적용기법에 관한 연구 (A Study on the Application Method of Photovoltaic in Building)

  • 이응직;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.1-10
    • /
    • 2002
  • This study is a study on the building integrated method of Photovoltaic. It was analyzed into a basic installation condition and an integrated form in this study. And it was confirmed through the 3D simulation & drawing work of an integrated situation to the real domestic building. The Photovoltaic installation of the country to an optimal efficiency for the year must be installed to the due south with an angle of thirty degrees. And also a module spacing must be more than doubled from the bottom to the top of module to prevent from efficiency falling by a shadow of photovoltaic module in a roof setting of flat roof. If Photovoltaic module is an adequate material that is a basic requirement as a building's finishing material, it's not only an efficiency of alternation with an existing finishing material but also a building's design element.

태양광 접속반의 화재 방지 시스템 (Fire Prevention Systems for Photovoltaic Connection Panel)

  • 한만수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.137-138
    • /
    • 2019
  • 태양광 접속반은 태양전지에서 발생된 전압을 인버터에 연결해주는 장치이다. 태양광 접속반에는 인버터에서 태양전지로 흐르는 역전압을 차단하기 위해 다이오드가 사용된다. 이 다이오드의 발열이 태양광 접속반 화재의 주 원인이다. 본 논문에서는 IoT 기기들을 사용하여 다이오드의 발열상태를 감시하고 화재를 예방하는 방법을 제안한다.

  • PDF