• 제목/요약/키워드: Photovoltaic(PV) Cell

Search Result 318, Processing Time 0.029 seconds

Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System (태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석)

  • Kang, Seung-Hyun;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.311-318
    • /
    • 2020
  • A photovoltaic (PV) system uses an AC module integrated converter (MIC) to operate PV cells at a maximum power point (MPP) and for high efficiency. The MPP of a PV cell varies depending on partial shading conditions, and loss occurs differently according to the configuration method of the PV-MIC. Therefore, this study compares the losses of passive components and power semiconductors according to the partial shading conditions of the PV module. Theoretical loss analysis is performed using parameters for the datasheet and PSIM simulation results. Analysis results verify that the one-stage PV-MIC demonstrates high efficiency.

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

Electrical Characteristics of Mono Crystalline Silicon Solar Cell for Concentrating PV System using Fresnel Lenses (프레넬 렌즈를 이용한 집광 시 단결정 실리콘 태양전지의 전기적 특성)

  • Kang, Kyung-Chan;Kang, Gi-Hwan;Yu, Gwon-Jong;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.218-219
    • /
    • 2007
  • Silicon feed stock shortage have acted as major restraints for growth of photovoltaic industry. Concentrating photovoltaic (CPV) system will reduce the use of silicon PV materials. This paper presents the application possibility of mono-crystalline silicon solar cell, which has increased in market share, for PV concentrator. We measured the power of solar cell using sun simulator and I-V curve tracer and compared the results. The comparison of results showed that the concentrated solar cell generated the power more approximately 7 times than without concentration in spite of non-heat sink. If CPV technology included heat sink combines already developed PV tracking system, it will have a merit economically.

  • PDF

Design of a Photo Energy Harvesting Circuit Using On-chip Diodes (온칩 다이오드를 이용한 빛에너지 하베스팅 회로 설계)

  • Yoon, Eun-Jung;Hwang, In-Ho;Park, Jun-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.549-557
    • /
    • 2012
  • In this paper an on-chip photo energy harvesting system with MPPT(Maximum Power Point Tracking) control is proposed. The ISC(Integrated Solar Cell) is implemented using p-diff/n-well diodes available in CMOS processes. MPPT control is implemented using the linear relationship between the open-circuit voltage of a PV(Photovoltaic) cell and its MPP(Maximum Power Point) voltage such that a small pilot PV cell can track the MPP of a main PV cell in real time. Simulation results show that the designed circuit with the MPPT control delivers the MPP voltage to load even though the load is heavy such that the load circuit can operate properly. The proposed circuit is designed in 0.18um CMOS process. The designed main PV cell and pilot PV cell occupy $8mm^2$ and $0.4mm^2$ respectively.

PV Module Configuration Considering Environment Conditions of Photovoltaic System (태양광 발전시스템의 환경조건을 고려한 PV 모듈 구성)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.31-41
    • /
    • 2014
  • This paper proposes the configuration of photovoltaic(PV) module considering the environment conditions of the PV system. The PV system is consisted of the series-parallel connection of the PV module. When shadows or changes of the radiation or an electrical characteristic in the solar cell are happened to PV system, the serious power loss will occur. If the PV module connected in series has the shadows, the output current is restricted to current of shaded PV module. Also if shadow is occurred to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, this paper proposes the method that makes the output power of the PV module equalize by reconfiguration of PV module using the switching considering these environment conditions. A validity of the method proposed in this paper proves through comparing with performance of conventional PV module.

A Study on the Optimal Voltage for MPPT Obtained by only Surface's Temperature of Solar Cell (태양전지 온도 센싱만을 통한 태양광 발전시스템의 최적 운전전압에 관한 연구)

  • Minwon Park;In-Keun Yi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Photovoltaic(PV) system has been studied and watched with keen interest due to a clean and renewable power source. But, the output power of PV system is not only unstable but uncontrollable, because the maximum power point tracking (MPPT) of PV system is still hard with the tracking failure under the sudden fluctuation of irradiance. Authors suggest that the optimal voltage for MPPT be obtained by only solar cell temperature. Having an eye on that the optimal voltage point of solar cell is in proportion to its panel temperature, with operating the power converter whose operating point keeps its input voltage to the optimal voltage imagined by the surface's temperature of PV panel, the maximum power point becomes tenderly possible to be tracked. In order to confirm the availability of the proposed control scheme. And both control methods are simulated not only on the various angle of sampling time of switching control, but also with the real field weather condition. As the results of that, the conversion efficiency between PV panel and converter of the proposed control scheme was much better than that of the power comparison MPPT control, and what is better, the output voltage of PV panel was extremely in stable when the optimal voltage for MPPT is obtained by only solar cell temperature.

A Study on the Applicability of Double-Sided Vertical Photovoltaic Panels Based on Energy Productivity Analysis (에너지 생산성 분석 기반 양면발전형 수직 태양전지의 활용 가능성 탐색)

  • Seung-Ju Choe;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.84-97
    • /
    • 2023
  • This study aimed to investigate the feasibility and potential applications of utilizing bifacial photovoltaic (PV) panels from an architectural perspective. It also aimed to establish a foundational dataset for installation and operational guidelines for bifacial PV panels through a comparative analysis of energy production performance with single PV panels. The research encompassed several key steps, including a comprehensive literature review, calculation of solar surface radiation values, development of datasets for bifacial and single PV energy production, and a performance comparison between both approaches. The results of the study show that bifacial PV panels exhibit optimized energy production capabilities within the range of 40 to 80 degrees, contingent upon the specific installation location. Consequently, it is recommended that the installation of bifacial PV panels in Korea should primarily focus on southwest-to-west orientation. Furthermore, it was concluded that bifacial PV panels could contribute an equivalent or even superior level of energy production compared to single PV panels, even if their performance exhibited a marginally lower efficiency of 2% to 5% with an 18% power generation efficiency.

A Study on the Application Method of Photovoltaic in Building (PV의 건축물 적용기법에 관한 연구)

  • Lee, E.J.;Kim, H.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.1-10
    • /
    • 2002
  • This study is a study on the building integrated method of Photovoltaic. It was analyzed into a basic installation condition and an integrated form in this study. And it was confirmed through the 3D simulation & drawing work of an integrated situation to the real domestic building. The Photovoltaic installation of the country to an optimal efficiency for the year must be installed to the due south with an angle of thirty degrees. And also a module spacing must be more than doubled from the bottom to the top of module to prevent from efficiency falling by a shadow of photovoltaic module in a roof setting of flat roof. If Photovoltaic module is an adequate material that is a basic requirement as a building's finishing material, it's not only an efficiency of alternation with an existing finishing material but also a building's design element.

Decomposition of EVA(Ethylene vinyl acetate) used as an adhesion of photovoltaic(PV) module by ultrasonic irradiation in bath-type cleaner (Bath-type 초음파(超音波) 세척기(洗滌器)를 이용(利用)한 태양전지모듈 접착제(接着劑) EVA(Ethylene Vinyl Acetate) 분해특성(分解特性))

  • Kim, Young-Jin;Lee, Jae-Ryeong
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • Using ultrasonic irradiation, the separation and recovery of PV cell, made of silicon wafer, from PV module was carried out through selective decomposition of EVA used as an interlaminated binder. The ultrasonic cleaner of bath-type (Output: 130 W, Frequency: 40 kHz) was used as an ultrasonic apparatus in this research. With the fixed distance of 2 cm, from ultrasonic generator to PV cell, the experiment of EVA decomposition was performed in various organic solvents such as Toluene, Trichloroethylene, O-dichlorobenzene, Benzene. And also their concentrations and temperature was changed to survey the optimum conditions. However EVA can be decomposed perfectly at $55^{\circ}C$ within 160 min in 5 M of all kinds of solvent, PV cell may be recovered with being damaged or broken severely. This damage may be resulted from the swelling of EVA in the process of decomposition. Whereas, at the condition of 5 M at $65^{\circ}C$, PV cell can be recovered with the state of minor damage or crack. This implies that the decomposition rate of EVA increases with an increase of temperature, thereby EVA can be decomposed before the swelling of EVA layer. Conclusively, it is possible for PV cell to be recovered within 40 min, at $65^{\circ}C$ in 5 M, with less damage.

The Durability Estimation of Crystalline PV Module according to Mechanical Stress (결정질 태양전지모듈의 외부 응력에 따른 장기적 내구성 예측)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.35-36
    • /
    • 2008
  • In this paper, we studied the long term durability estimation for crystalline photovoltaic module while exposing to mechanical stress. Solar cell and PV module have many different kinds of stresses from cell to module fabrication. For this reason, some solar cell shows micro crack that decrease crystallization. In here, we expose artificial mechanical load on surface of PV module. Through this, the periodic external force on PV module might give an negative effect. The further analysis is described in the following paper.

  • PDF