• Title/Summary/Keyword: Photovoltaic's array

Search Result 57, Processing Time 0.025 seconds

A Study on Optimizing of Roof-Top Photovoltaic Arrays Arrangement Based on Three-Dimensional Geo-Spatial Information (3차원 지형공간정보 기반 지붕형 태양광 어레이 배치 최적화 연구)

  • Kim, Se-Jong;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.151-159
    • /
    • 2011
  • Due to the Korean government's renewable energy support policy such as the renewable energy utilization building certificate and enlarging the compulsory ratio of investment on the public building, the rooftop photovoltaic projects are expanding rapidly. It is very important for the rooftop photovoltaic projects to analyze the shading effect of the adjacent structures or own facilities. But, the photovoltaic arrangements are planned by the experience of the designers or simple graphic tools. The purpose of this study is to build the process model for optimizing of rooftop photovoltaic arrangement based on three-dimensional geo-spatial information.

Utility Interactive Photovoltaic Generation System Using Discontinuous Mode Buck-Boost Chopper (불연속모드 승강압초퍼를 이용한 계통연계형 태양광발전 시스템)

  • 김영철;이현우;서기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.325-331
    • /
    • 1999
  • In a utility interactive photovoltaic generation system. a PWM inverter is used for the connection between the p photovoltaic arrays and the utility. The dc current becomes pulsated when the conventional inverter system operates i in the continuous current mode and de current pulsation causes the distortion of the accurrent waveform. This paper p presents the reduced pulsation of de input current by operating the inverter with buck-boost chopper in the d discontinuous conduction mode. The dc current which contains harmonic component is analyzed by means of s separating into two terms of a ripple component and a direct component. The constant dc current without p pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provides a sinusoidal ac c current for domestic loads and the utility line with unity power factor.

  • PDF

Photovoltaic Power Generation Control by A Partial Resonant Buck-Boost chopper circuit (부분공진 승강압 초퍼회로에 의한 태양광발전제어)

  • Byun, H.G.;Moon, S.P.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.413-415
    • /
    • 1997
  • The solar cell has an optimum operating point to be able to get maximum power. To obtain maximum power from Photovoltaic array, potovolt aic power syste usually requres maximum power point tracking controller. The output characteristics of solar cell are nonlinear, and these characteristics vary with load solar insolation, solar cell temperature. Therefore the tracking control of maximum power point is the complicated problem. This paper presents power characteristics of residential Photovoltaic system applying a quck-boost conversion system.

  • PDF

Single-Phase PCS with UPS Function Based on Dc Bus Oriented Control (dc bus 중심 제어를 이용한 UPS 기능을 갖는 단상 태양광 발전 시스템)

  • Kim, Eung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.293-296
    • /
    • 2007
  • 본 논문에서는 UPS 기능을 갖는 단상 태양광 발전 시스템을 제안하였다. 제안하는 시스템은 태양광 어레이 (photovoltaic array)에서 최대전력을 얻기 위해 MPPT (maximum power point tracking)를 수행하는 컨버터, 계통전원 상태나 태양광 발전량에 상관없이 부하에 정현파 전압을 공급하는 인버터, 태양광 어레이에서 발전된 잉여전력을 계통으로 전달하거나 부하에 필요한 전력을 dc bus로 공급하는 인버터, 정전시 dc bus에 전력을 공급하는 양방향 컨버터 (bidirectional converter)로 구성된다. 제안하는 시스템은 발전된 전력을 계통으로 전달할 뿐만 아니라, UPS (uninterruptible power supply)기능도 수행하는 시스템으로 계통전압이 불안정하거나 정전시에도 부하에 안정적이고 깨끗한 전압을 항상 공급할 수 있다. 각각의 인버터, 컨버터, 및 양방향 컨버터는 dc bus를 공유하며, dc bus의 전압에 따라 동작상태가 결정이 된다. dc bus중심의 제어는 dc bus전압을 안정적으로 유지시키며, 부하에 걸리는 전압의 변동을 최소로 하고 시스템의 디자인 및 제어를 단순화한다. 모든 알고리즘과 제어기를 하나의 마이크로 컨트롤러로 구현하였고 제안된 시스템의 우수성을 실험을 통해 검증하였다.

  • PDF

Research and Experimental Implementation of a CV-FOINC Algorithm Using MPPT for PV Power System

  • Arulmurugan, R.;Venkatesan, T.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1389-1399
    • /
    • 2015
  • This research suggests maximum power point tracking (MPPT) for the solar photovoltaic (PV) power scheme using a new constant voltage (CV) fractional order incremental conductance (FOINC) algorithm. The PV panel has low transformation efficiency and power output of PV panel depends on the change in weather conditions. Possible extracting power can be raised to a battery load utilizing a MPPT algorithm. Among all the MPPT strategies, the incremental conductance (INC) algorithm is mostly employed due to easy implementation, less fluctuations and faster tracking, which is not only has the merits of INC, fractional order can deliver a dynamic mathematical modelling to define non-linear physiognomies. CV-FOINC variation as dynamic variable is exploited to regulate the PV power toward the peak operating point. For a lesser scale photovoltaic conversion scheme, the suggested technique is validated by simulation with dissimilar operating conditions. Contributions are made in numerous aspects of the entire system, including new control algorithm design, system simulation, converter design, programming into simulation environment and experimental setup. The results confirm that the small tracking period and practicality in tracking of photovoltaic array.

Cascaded H-Bridge Five Level Inverter for Grid Connected PV System using PID Controller

  • Sivagamasundari, M.S.;Mary, P. Melba
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.451-462
    • /
    • 2016
  • Photovoltaic energy conversion becomes main focus of many researches due to its promising potential as source for future electricity and has many advantages than the other alternative energy sources like wind, solar, ocean, biomass, geothermal etc. In Photovoltaic power generation multilevel inverters play a vital role in power conversion. The three different topologies, diode-clamped (neutral-point clamped) inverter, capacitor-clamped (flying capacitor) inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each pv array can act as a separate dc source for each h-bridge module. This paper presents a single phase Cascaded H-bridge five level inverter for grid-connected photovoltaic application using sinusoidal pulse width modulation technique. This inverter output voltage waveform reduces the harmonics in the generated current and the filtering effort at the input. The control strategy allows the independent control of each dc-link voltages and tracks the maximum power point of PV strings. This topology can inject to the grid sinusoidal input currents with unity power factor and achieves low harmonic distortion. A PID control algorithm is implemented in Arm Processor LPC2148. The validity of the proposed inverter is verified through simulation and is implemented in a single phase 100W prototype. The results of hardware are compared with simulation results. The proposed system offers improved performance over conventional three level inverter in terms of THD.

Diagnosis Method of Output Power Lowering of PV System by Using Kalman Filter Algorithm (Kalman Filter 알고리즘을 이용한 태양광 발전 시스템의 출력저하 진단법)

  • Kang, Byung-Kwan;Kim, Seung-Tak;Lee, Hyun-Gu;Bae, Sun-Ho;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1537-1546
    • /
    • 2011
  • The photovoltaic(PV) generation system have recently become widely used to solve the environmental problems and running out of fossil fuels. However, the study on maintenance is inadequate for PV system. This paper proposes the novel diagnosis method of output power decline to maintain the normal output performance of PV array. The diagnosis method used the proportional relation of irradiation-output current(S-I) of PV array at maximum power point(MPP). And, first order polynomial using the relation is proposed to easily apply PV system. To estimate the relation in case of separation of PV array producer and diagnosis system producer. Kalman Filter algorithm is also proposed at 30.2kW grid-connected PV system. Then, the performance of diagnosis method is evaluated using the hardware tests as well as the simulation.

NPV-BASED 3D ARRAY DESIGN SYSTEM OF ROOF-TOP PHOTOVOLTAICS

  • Kim Se-Jong;Cho Dong-Hyun;Park Hyung-Jin;Yoon Hee-Ro;Koo Kyo-Jin
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.300-303
    • /
    • 2013
  • On BIPV systems, especially roof-top PV systems, the power generation is easier to be reduced due to the shades of facilities nearby, or roof itself. To secure profitability of roof-top PV systems, the optimal design of solar arrays through the precise shading analysis is an important item of design considerations. In this paper, an optimization system for array design of roof-top PVs is to be developed using three-dimensional Geospatial Information System(GIS). The profitability of income and expense is considered through the shading analysis of entire roofs. By applying the system to project for validation, the adequacy and the improvement of NPV of the system were verified compared to expert's design. The system has significance by reason that PV modules are placed through rules established with expert knowledge and geometric rules were applied to reflect the constructability and maintainability.

  • PDF

A Photovoltaic Device Model for Grid-connected PV System Simulation (계통연계형 태양광발전시스템의 태양광전지모델 시뮬레이션)

  • Campbell, Ryan;Kim, Hak-Man;Lee, Jong-Su;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.18-19
    • /
    • 2006
  • The recent interest in distributed generation (DG) due to the opening of the electricity market and the need for alternatives to conventional fossil fuel-based electricity generation has created renewed interest in grid-connected photovoltaic(PV) systems. Many studies are being performed at the power system level to examine the impacts of grid-connected PV systems and several models for PV arrays have been proposed in the literature. However, the complexity of these models and difficulties of implementing them in various software programs can be deterrents to their use. This paper proposes a robust and flexible PV device model suitable for dynamic and transient studies where the PV array's non-linear DC characteristics are important. The model's implementation in software is straightforward and it can even be constructed using standard software library components, as demonstrated using PSCAD/EMTDC.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF