• 제목/요약/키워드: Photon-counting detector

검색결과 31건 처리시간 0.022초

색소 농도에 따른 형광 광자의 계수율 : 광자 검출기의 dead time 효과 (Fluorescence photon counting rate as a function of dye concentration: Effect of dead time of photon detector)

  • 고동섭
    • 한국광학회지
    • /
    • 제8권4호
    • /
    • pp.353-355
    • /
    • 1997
  • 공초점 형광 현미경과 단일 광자 계수기로 구성되어 있는 단일 분자 검출장치를 사용하여, 색소 농도에 따른 광자 계수율의 변화를 관측하였다. 농도가 증가함에 따라 계수율이 포화하는 경향을 보였으며, 광검출기의 죽은 시간을 고려하여 측정 결과를 설명하였다. 계수율과 검출 부피, 광검출기의 양자효율, 입사 광량 사이의 관계를 나타내는 관계식을 제시하였다. 또한 신호대 잡음비에 대해서도 간략하게 논하였다.

  • PDF

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging

  • Jan-Peter Grunz;Henner Huflage
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.662-672
    • /
    • 2024
  • Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.

배열형 실리콘광증배소자를 이용한 포톤 카운팅 검출기 설계를 위한 몬테칼로 시뮬레이션 연구 (Monte-carlo Simulation for X-ray Photon Counting using MPPC Arrays)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.929-934
    • /
    • 2018
  • 영상의 질 향상과 물질 분석 등을 위해 엑스선을 카운팅하여 검출하기 위한 연구가 활발하다. 본 연구에서는 MPPC 어레이를 사용하여 엑스선 포톤 카운팅을 위한 검출기를 설계하였고, 시뮬레이션을 통해 검출기 특성을 평가하였다. GATE를 사용하여 엑스선과 섬광체와 반응한 위치 정보를 획득하였고, 이 정보를 DETECT2000의 빛 발생 위치로 사용하였다. 0.5 mm와 1 mm 두께의 GAGG 섬광체를 사용하였으며, $4{\times}4$ 어레이의 MPPC를 통해 발생된 빛을 획득하였다. 각 채널별로 획득한 빛의 신호를 통해 영상을 재구성하여 설계한 검출기의 분해능을 확인하였다. 0.5 mm와 1 mm 두께의 GAGG 섬광체에서 모두 2 lp/mm 이상의 영상을 획득하였다. 본 검출기를 엑스선 시스템에 사용할 경우 포톤 카운팅이 가능한 저비용의 시스템을 구축할 수 있을 것이다.

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

Photon-counting digital holography

  • Hayasaki, Yoshio
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.165-166
    • /
    • 2009
  • A hologram was recorded with two-dimensional scanning of an optical fiber connected to a single-photon counting detector under ultra-weak illumination. The object image was clearly reconstructed in a computer from the hologram. The dependence of hologram quality on the illumination light intensity was estimated.

  • PDF

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

단일광자 검출기 기술개발 동향 (Single Photon Detectors Technologies Development Trends for Quantum Information)

  • 이욱재;심재식;윤천주
    • 전자통신동향분석
    • /
    • 제35권4호
    • /
    • pp.21-33
    • /
    • 2020
  • Single photon detector technologies have emerged as powerful tools in optical quantum information applications such as quantum communication, quantum information, and integrated quantum photonics. Owing to significant attempts in the previous decade at improving photon-counting detectors, several single photon detectors with high efficiency and low noise have been realized within the optical wavelength regime. In this paper, we provide an overview of current studies on single photon detectors operating at wavelengths from the ultraviolet to the infrared. In addition, we discuss applications of single photon detector technologies in quantum communication and integrated quantum photonics.