• Title/Summary/Keyword: Photomultiplier tube

검색결과 59건 처리시간 0.022초

전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구 (A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography)

  • 임윤빈;문홍만;조현택;백영종;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1741-1744
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

  • PDF

Development of a wireless radiation detection backpack using array silicon-photomultiplier (SiPM)

  • Kim, Jeong Ho;Back, Hee Kyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.456-460
    • /
    • 2020
  • In this research, a radiation detection backpack to be used discreetly or by a wide range of users was developed using array silicon-photomultiplier (SiPM) and CsI (Tl), and its characteristics were evaluated. The R-squared value, which indicates the responsiveness of a detector based on the signal intensity, was determined to be 0.981, indicating a good linear responsivity. The energy resolutions for gamma radiation energies of Co-57 (122 keV), Ba-133 (356 keV), Cs-137 (662 keV), and Co-60 (1332 keV) were found to be 13.40, 10.50, 6.77, and 3.16%, respectively. These results confirm good energy resolution characteristics. Furthermore, in the case of mixed sources, the gamma radiation peaks were readily distinguishable, and the R-squared value for energy linearity was calculated to be 0.999, demonstrating an exceptional energy linearity. Further research based on the results of this study would enable the commercialization of lightweight SiPM-based wireless radiation detection backpacks that can be used for longer durations by replacing the photomultiplier tube, which is mainly used as the optical sensor in existing radiation detection backpacks.

광전자증폭관에 의한 키토산 첨가 사료를 사용한 양돈 생체조직에서의 육질 품질 비교 측정 (Photomultiplier Tube Emission of Protein and fat specimens from the sirloin of a Chitosan-fed pig Comparison of meat quality)

  • 민제호;유종수;천병수
    • 한국전자통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.323-328
    • /
    • 2014
  • 키토산 첨가 혼합사료를 섭취한 양돈 근육 조직과 일반 사료를 섭취한 조직에서의 품질을 비교하기 위한 방법으로 생체광자를 이용한 광전자증폭관(Photomultiplier Tube, PMT) 기기를 사용하여 측정한 결과 서로 다른 결과를 얻었다. 키토산 첨가제를 사용한 돼지 등심조직에서의 육질 비교를 PMT와 현미경을 사용하여 측정한 결과 키토산 첨가 혼합 사료를 먹인 돼지 등심 조직의 생체광자 양을 측정한 결과 서로 상이한 수치를 얻을 수 있었다. 이것으로 조직의 품질을 비교 측정이 가능했다. 또한 이조직의 형태를 해부현미경으로 관찰한 결과 키토산 첨가 혼합사료 근육 조직의 육질이 더 섬세하고 촘촘하여 지방질이 적고 맛이 좋다는 것을 알 수 있었다. 따라서 PMT에 의한 조직 육질 측정은 생화학적 상태변화를 측정하는 새로운 분석법의 하나가 될 것으로 기대되어진다.

이동형 감마프로브 개발과 기본성능 평가 (Development of Portable Gamma Probe and Its Basic Performance Test)

  • 김희중;곽철은;최용;양묘근;봉정균;이상철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.216-219
    • /
    • 1997
  • We are developing a portable multipurpose gamma counting and imaging probe that will be useful for many applications in nuclear medicine including radioimmunoguided surgery in the detection and treatment of malignant tumors. Any diagnostic information provided by CT, MRI, PET, SPECT or gamma camera imaging prior to surgery obviously is very important, but current techniques are limited in many instances. To overcome some of these limitations, the portable multipurpose gamma probe is being developed. The gamma probe consists of NaI(Tl) crystal with 1" dia $\times$ 0.5" thick and singlechannel photomultiplier tube (SC-PMT) for counting, and 3" dia $\times$ 0.375" and multichannel photomultiplier tube (MC-PMT) for imaging, nuclear instrument module (NIM), position circuits, interface, and PC. The energy resolution using Tc-99m was measured as 14% and the spatial resolution using 3mm dia green LED was measured as 2.9mm. These priliminary results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine.

  • PDF

주사전자현미경용 전자검출기의 설계 및 제작 (Design and Manufacture of an Electron Detector for Scanning Electron Microscope)

  • 전종업;김지원
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

환형제트에서의 메탄과 공기의 층류 예혼합 화염에서 발생되는 자발적인 소음에 대한 실험적 연구 (Self-Excited Noise Generation from Laminar Methane/Air Premixed Flames in Thin Annular JetsPut)

  • 진성호;정재훈;권성준;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.159-165
    • /
    • 2003
  • Self-excited noise generation from laminar flames in thin annular jets of methane/air premixture has been investigated experimentally. Various flames were observed in this flow configuration, including conical shape flames, ring shape flames, steady crown shape flames, and oscillating crown shape flames. Self-excited noise with the total sound pressure level of about 70dB was generated from the oscillating crown shape flames for the equivalence ratio larger than 0.95. Sound pressure and $CH^{\ast}$ chemiluminescence were measured by using a microphone and a photomultiplier tube. The frequency of generated noise was measured as functions of equivalence ratio and premixture velocity. A frequency doubling phenomena have also been observed. The measured $CH^{\ast}$ chemiluminescence data were analyzed from which the corresponding sound pressure has been calculated. By comparing the data with those of measured ones, the noise source can be attributed to the flame front fluctuation near the edge of the oscillating crown-shape flames. The flame stability regime was influenced sensitively to the supplying air through the inner tube.

  • PDF

Evaluation of the 256ch Flat Panel PS-PMT on Positioning Image Histogram for PET

  • Orita, Narimichi;Murayama, Hideo;Kawai, Hideyuki;Inadama, Naoko;Umehara, Takaya;Kasahara, Takehiro;Tsuda, Tomoaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.324-327
    • /
    • 2002
  • For a next generation PET that realizes high sensitivity and high resolution, we proposed a design of a depth of interaction detector. A unit of the detector is constructed of four stages rectangular blocks of 2 by 2 Gd$_2$SiO$\sub$5/: Ce (GSO) crystal array optically coupled to position sensitive photomultiplier tube (PS-PMT). The 256ch flat panel PS-PMT is under development by Hamamatsu Photonics K.K., JAPAN. It has large cathode area, 51.7 by 51.7 mm$^2$, and the ratio of the effective area to external size is about 90%. The feature will contribute high packing fraction, accordingly high sensitivity. The 256 anodes are arranged in 16 by 16 at intervals of 3.0 mm. So as to evaluate the detector capability for identifying crystal of interaction, we got positioning image histograms with coupling a 16 by 5 array of GSO crystals, 2.9 by 2.9 by 7.5 mm$^3$, to the PS-PMT by irradiating a gamma ray uniformly from a point source. Flat panel PS-PMT is a new promising device for PET. We need to evaluate it if its performance is sufficiency. The performance was compared to the one with a 16ch PS-PMT.

  • PDF

자동차용 광원의 광도분포 측정장치(배광측정기)제작 (Construction of a Distribution Photometer System for Automobile Light Sources)

  • 김용완;김홍기;이인원;이완순;이상원
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권4호
    • /
    • pp.53-61
    • /
    • 1996
  • 광원에 대하여 서로 다른 여러 각도방향에서 광원을 바라볼 때 관측되는 광도 분포 및 재귀반사성능을 측정하기 위해 광도 분포 측정장치(배광측정기)를 제작하였다. 이 장치는 광원을 좌우로 360도, 상하로 $\pm$30도 회전 시킬수 있는 광원회전장치, 광검출기로 광전자증배관(PM Tube)을 쓰는 수광부 및 재귀반사성능 측정용 투광기와 제어 및 표시부로 구성되어 있다. 광도측정범위는 0.01~199900cd, 관측각범위는 0.2~1.5도 이고 광도의 측정오차는 $\pm$3%이다. 제작된 장치의 구조와 성능평가결과가 제기되었다.

  • PDF