In this research, a radiation detection backpack to be used discreetly or by a wide range of users was developed using array silicon-photomultiplier (SiPM) and CsI (Tl), and its characteristics were evaluated. The R-squared value, which indicates the responsiveness of a detector based on the signal intensity, was determined to be 0.981, indicating a good linear responsivity. The energy resolutions for gamma radiation energies of Co-57 (122 keV), Ba-133 (356 keV), Cs-137 (662 keV), and Co-60 (1332 keV) were found to be 13.40, 10.50, 6.77, and 3.16%, respectively. These results confirm good energy resolution characteristics. Furthermore, in the case of mixed sources, the gamma radiation peaks were readily distinguishable, and the R-squared value for energy linearity was calculated to be 0.999, demonstrating an exceptional energy linearity. Further research based on the results of this study would enable the commercialization of lightweight SiPM-based wireless radiation detection backpacks that can be used for longer durations by replacing the photomultiplier tube, which is mainly used as the optical sensor in existing radiation detection backpacks.
The gain change of the photomultiplier which occurs as the count rate increased was examined. and simple feedback resistor series was introduced between 7th and 9th dynode for compensating the gain change. The effect of the feedback resistor series was considerably good to reduce the gain change. With the feedback resistor, the gain change was only 1.9%, when count rate was increased from 514 CPS (counts per second) to 1250 CPS. Without the feedback resister, the gain change was 6.9%, when the count rate was increased from 530 CPS to 1250 CPS.
The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.
In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.
키토산 첨가 혼합사료를 섭취한 양돈 근육 조직과 일반 사료를 섭취한 조직에서의 품질을 비교하기 위한 방법으로 생체광자를 이용한 광전자증폭관(Photomultiplier Tube, PMT) 기기를 사용하여 측정한 결과 서로 다른 결과를 얻었다. 키토산 첨가제를 사용한 돼지 등심조직에서의 육질 비교를 PMT와 현미경을 사용하여 측정한 결과 키토산 첨가 혼합 사료를 먹인 돼지 등심 조직의 생체광자 양을 측정한 결과 서로 상이한 수치를 얻을 수 있었다. 이것으로 조직의 품질을 비교 측정이 가능했다. 또한 이조직의 형태를 해부현미경으로 관찰한 결과 키토산 첨가 혼합사료 근육 조직의 육질이 더 섬세하고 촘촘하여 지방질이 적고 맛이 좋다는 것을 알 수 있었다. 따라서 PMT에 의한 조직 육질 측정은 생화학적 상태변화를 측정하는 새로운 분석법의 하나가 될 것으로 기대되어진다.
The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.
Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.
본 연구에서는 실리콘 광 증배소자(Silicon photomultiplier)와 Ce:GAGG 섬광체 단결정을 이용한 섬광검출기를 제작하고, 감마선 분광특성 분석을 통해 기존에 상용화된 LYSO, CsI:Tl 섬광체와의 분광특성을 비교하였다. 섬광체 단결정의 크기는 $3{\times}3{\times}20mm^3$ 이며 $3{\times}3mm^2$ 실리콘 광 증배소자를 이용하여 섬광검출기를 제작한 후, 표준 감마선원인 $^{133}Ba$, $^{22}Na$, $^{137}Cs$, $^{60}Co$에 대한 에너지 분해능을 각각 측정하고 비교하였다. 그 결과 Ce:GAGG 섬광검출기의 감마선에 대한 에너지 분해능은 $^{133}Ba$ 0.356 MeV에서 13.5%, $^{22}Na$ 0.511 MeV에서 6.9%, $^{137}Cs$ 0.662 MeV에서 5.8% 그리고 $^{60}Co$ 1.33 MeV에서 2.3%의 분광 특성을 확인 할 수 있었다.
본 논문에서는 고감도 보급형 방사선 측정센서 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 섬광체+광증배소자(SiPM) 센서 최적화 구조설계, 센서 드라이버용 증폭과 필터 및 제어회로 설계, 근거리 통신을 포함한 제어회로 설계, 센서 기구설계 및 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 섬광체+광증배소자(SiPM) 센서 최적화 구조 설계는 센서 구조 설계를 위한 섬광체와 광증배소자(SiPM)의 특성을 확인하여 설계한다. 센서 드라이버용 증폭과 필터 및 제어회로 설계는 SiPM을 이용하여 섬광체로 방사선에 의해 발생하는 미세 섬광신호를 처리하도록 설계한다. 근거리 통신을 포함한 제어회로 설계는 근거리 무선통신 기능을 지원하기 위한 MCU 설계 및 유선 통신 지원을 통해 데이터 전송이 가능하도록 설계를 수행한다. 센서 기구설계 및 제작은 플라스틱 섬광체에서 발생한 미세 섬광 신호를 광증배소자(SiPM)에 전달하기 위해 플라스틱 섬광체 외부에 반사지(미러링)를 감싸 발생한 섬광이 반사되어 효율을 높이도록 설계한다. 시제품에 적용되는 GUI 개발은 각 화면에 따라 상단에 날짜와 시간을 표현하며, 측정단위 및 시간, 초, 알람 레벨, 통신상태, 배터리 용량 등이 표현되도록 한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선량 측정 범위가 30𝜇Sv/h ~ 10mSv/h로 측정되어서, 현재 국내외에서 상용으로 판매되는 제품들 중에서 최고수준 범위와 같은 결과가 산출되었다. 또한, ±7.4%의 측정 불확도가 측정되어서 국제 표준인 ±15% 이하에서 정상동작 됨이 확인되었다
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.