• 제목/요약/키워드: Photometric Calibration

검색결과 45건 처리시간 0.023초

Status of KASI's Contribution to SPHEREx

  • Jeong, Woong-Seob;Yang, Yujin;Park, Sung-Joon;Pyo, Jeonghyun;Jo, Youngsoo;Kim, Il-Joong;Bang, Seungcheol;Lee, Bomee
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.53.1-53.1
    • /
    • 2021
  • The KASI team are participating in the NASA MIDEX mission (PI Institute: Caltech), the all-sky infrared spectro-photometric surveyor SPHEREx (Spectro-Photometer for the History of the Universe, Epoch of Reionization, and Ices Explorer). The SPHEREx will provide us the first all-sky infrared spectro-photometric data set to probe the origin of our Universe, to explore the origin and evolution of galaxies, and to explore whether planets around other stars could harbor life. After the project PDR (Preliminary Design Review) was successfully passed on the last September, the fabrication of flight hardware is in progress. As an international partner, KASI deeply involved in all fields of projects, i.e., the development of calibration facility, the construction of data reduction modules and the science studies for the SPHEREx. After finishing the fabrication and test of calibration facility for the SPHEREx in this year, it will be delivered to Caltech. Here, we report the status of the SPHEREx project and the progress in the Korean participation.

  • PDF

Flux calibration method for narrow band imaging observation

  • Ahn, Hojae;Pak, Soojong;Kang, Wonseok;Kim, Taewoo;Shim, Hyunjin
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.49.2-49.2
    • /
    • 2018
  • Flux calibration for narrow band photometric data gives us an opportunity to get a line flux of extended targets. We developed flux calibration processes for narrow band photometry using broad band filters as a continuum indicator. We derived parameters for color correction and zero point correction including color terms. Applying our method, we successfully subtracted continuum emissions and calibrated the emission lines from an FU Ori type object, V960 Mon.

  • PDF

Flare and Starspot-induced Variabilities of Red Dwarf Stars in the Open Cluster M37: Photometric Study on Magnetic Activity

  • Chang, Seo-Won
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.83.2-83.2
    • /
    • 2014
  • Flare and rotational variabilities induced by stellar activity are important for studying the effect of magnetic fields on the evolution of red dwarf stars. The level and frequency of magnetic activity in these stars have a different aspect at every moment of the observations due to the effect of age-rotation relation. The use of both tracers is thus essential to have a relatively homogeneous set of stellar activity data for statistical studies. The archival light curves and imaging data of the open cluster M37 taken by MMT 6.5m telescope were used for this work. In order to achieve much more accurate photometric precisions and also to make the most efficient use of the data, the entire imaging database were re-analyzed with our new time-series photometry technique and carefully calibration procedures. Based on the new light curves, we study, for the first time, a variety of aspects of those two variabilities in red dwarfs and their relation to magnetic activity. In this talk, we present all observational evidences that support the idea that the strength of magnetic activity is closely connected with the rotation rate of a star and its evolutionary status (age-activity-rotation paradigm). In conclusion, we suggest future directions to improve our understanding of stellar activity in cool stars with photometric time-series data.

  • PDF

환원황화합물의 분석과 검량기준의 선택에 따른 오차발생의 특성 (Selection of Calibration Approaches and Their Impact on the Quantification of Unknown Samples: Case Study on Reduced Sulfur Gases)

  • 조효재;홍원필;김기현
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.133-141
    • /
    • 2011
  • In this study, different calibration approaches for reduced sulfur compounds (RSCs) were investigated by using thermal desorption coupled with gas chromatography (GC) and pulsed flame photometric detection (PFPD). To evaluate the effects of calibration procedures, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) prepared at 10 ppm level were analyzed at 7 loading injection volumes (40, 60, 80, 100, 160, 240, and 320 ${\mu}L$). The results were then compared with calibration curves made with the Z (zero offset) and N (non-zero offset) method. The concentrations of unknown samples were then quantified by using R (ratio) method in which the slope values are compared between standards and samples. Secondly, in A (average) method, results obtained from a multi-point analysis of unknown samples were also averaged to extract representative values for each sample. Results of both experiments showed that analytical error of low molecular weight components (such as $H_2S$ and $CH_3SH$) was greatly expanded with the Z method. In conclusion, the combined application of N-A method was the more realistic approach to reduce biases in the quantification of RSCs.

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

SOME CHARACTERISTICS OF FIELD STARS

  • Lee, See-Woo;Choe, Seung-Urn
    • 천문학회지
    • /
    • 제21권1호
    • /
    • pp.1-36
    • /
    • 1988
  • The temperature calibration of stars by photometric parameters and spectral type is discussed, using the catalogue data of Cayrel de Strobel et al. (1985) and Morel et al. (1976). The H-R diagrams and the mass-luminosity relation of stars in this catalogue are presented in the [log(L/M)-log $T_e$]-and [$M_{bol}$-log(L/M)]-planes, respectively, discussing the age of main sequence (MS) stars and giant stars. The age-metallicity relation of the nearby stars suggests the initial rapid enrichment of metal abundance.

  • PDF

Simultaneous Determination of Alkaline Earth Metal Ions by a Conventional High Performance Liquid Chromatographic System

  • Rho, Young-Soo;Choi, Seung-Gi
    • Archives of Pharmacal Research
    • /
    • 제9권4호
    • /
    • pp.211-214
    • /
    • 1986
  • A simultaneous determination method of alkaline earth metals was attempted with the conventional high performance liquid chromatographic system. Four cations, namely, magnesium, calcium, strontium and barium ion, were injected directly as aqueous solution into an eluent containing copper chloride solution and and were successfully separated and determined on a separating column (Zipax SCX, 4.6 mm i.d. ${\times}25$ cm length, Du Pont, USA) by using a variable wavelength UV detector. The linear calibration curves were obtianed in the range from $1.0{\times}10^{-4}M$ to $5.0{\times}10^{-4}M$ and the correlation coefficient of the calibration curve for each metal of magnesium and calcium in tap water. Alkaline earth metals were determined with the conventional high performance liquid chromatographic system.

  • PDF

Calibration transfer between miniature NIR spectrometers used in the assessment of intact peach and melon soluble solids content

  • Greensill, Colin.V.;Walsh, Kerry.B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1127-1127
    • /
    • 2001
  • The transfer of predictive models using various chemometric techniques has been reported for FTNIR and scanning-grating based NIR instruments with respect relatively dry samples (<10% water). Some of the currently used transfer techniques include slope and bias correction (SBC), direct standardization (DS), piecewise direct standardization (PDS), orthogonal signal correction (OSC), finite impulse transform (FIR) and wavelet transform (WT) and application of neural networks. In a previous study (Greensill et at., 2001) on calibration transfer for wet samples (intact melons) across silicon diode array instrumentation, we reported on the performance of various techniques (SBC, DS, PDS, double window PDS (DWPDS), OSC, FIR, WT, a simple photometric response correction and wavelength interpolative method and a model updating method) in terms of RMSEP and Fearns criterion for comparison of RMSEP. In the current study, we compare these melon transfer results to a similar study employing pairs of spectrometers for non-invasive prediction of soluble solid content of peaches.

  • PDF

The Off-Axis Properties of Solar X-Ray Telescopes: I. Evaluation of the Vignetting Effect

  • 신준호
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • The solar X-ray telescopes, the Yohkoh SXT and the Hinode XRT, have observed for a couple of decades a variety of coronal structures in the range of wide field-of-view (FOV) covering the full solar disk. It has been emphasized that the optical structure of solar telescopes should be designed with care for improving the uniformity over the full FOV. The vignetting effect is one of the important optical characteristics for describing the performance of a telescope, which reflects the ability of collecting the incoming light at different locations and different photon energies. The correction of this vignetting effect would be an important calibration step that should be performed in advance, especially when the observed images are to be used for photometric purposes. Since the vignetting effect of solar X-ray telescopes shows wavelength dependence, a special care should be taken when, for example, performing the temperature analyses with thin and thick filters for flaring activities observed at the periphery of the full FOV. The results of analysis of pre-launch calibration data for the evaluation of vignetting effect will be introduced in detail.

  • PDF

환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구 (Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air)

  • 김기현;오상인;최여진;최규훈;주도원
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.